Versiv Professional Kit with DSX2-8000 CableAnalyzer, Quad OLTS, Quad OTDR, Fiber Inspection with WiFi adapter and a full complement of product accessories. This is the wireless version and includes a WiFi adapter for LinkWare Live.
Versiv Professional Kit with DSX2-8000 CableAnalyzer, Quad OLTS, Quad OTDR, Fiber Inspection with WiFi adapter and a full complement of product accessories. This is the wireless version and includes a WiFi adapter for LinkWare Live.
As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provide accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements and the difference between being profitable or not can be just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy (making jobs easier to manage), and getting to system acceptance faster. It's not just for the expert technicians and project managers, individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.
Features
Copper Certifications | |
Category 6A / Class EA Test Time | 8 Seconds |
Category 8 / Class I/II Test Time | 15 Seconds |
HDTDX/HDTDR Diagnostic Test Times | ~3 Seconds |
Internal Memory | ~5,000 Cat 8 with plots ~12,000 Cat 6A with plots |
Level V Accuracy | 1 GHz |
2G Accuracy | 2 GHz |
Resistance Unbalance Measurement | Yes |
Shield Integrity Check | Yes |
TCL Measurement | Yes |
ELTCTL Measurement | Yes |
CDNEXT Measurement | Yes |
CMRL Measurement | Yes |
Built in Alien XTalk Module | Yes |
Channel Adapter | 2 GHz Range |
Permanent Link Adapter | 2 GHz Range |
Environmental | |
Operating Temperature | 32°F to 113°F (0°C to 45°C) |
Storage Temperature | -22°F to 140°F (-30°C to 60°C) |
Operating Relative Humidity (% RH Without Condensation) | 0% to 90%, 32°F to 95°F (0°C to 35°C) 0% to 70%, 95°F to 113°F (35°C to 45°C) |
Vibration | Random, 2 g, 5 Hz-500 Hz |
Shock | 1 m drop test with and without module and adapter |
Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
Operating Altitude | 13,123 ft (4,000 m) 10,500 ft (3,200 m) with AC Adapter |
EMC | EN 61326-1 |
General Specifications | |
Autotest Time | Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds |
Support Test Parameters | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
Display | 5.7 in LCD display with a projected capacitance touchscreen |
Case | High impact plastic with show absorbing overmold |
Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
Main Unit and Remote | Lithium ion battery pack, 7.2 V |
Typical Battery Life | 8 hours |
Charge time | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity |
Languages Supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian |
Calibration | Service center calibration period is 1 year |
Versiv Mainframe and Accessories:
DSX CableAnalyzer:
CertiFiber Pro Quad OLTS:
OptiFiber Pro Quad OTDR:
Fiber Inspection and Cleaning:
Click on a category to view a selection of compatible accessories with the Fluke Networks DSX2-8000-PRO-W 2GHZ Pro Kit with WiFi, DSX, CFP, OFP, INSPC.
Copper Certifications | |
Category 6A / Class EA Test Time | 8 Seconds |
Category 8 / Class I/II Test Time | 15 Seconds |
HDTDX/HDTDR Diagnostic Test Times | ~3 Seconds |
Internal Memory | ~5,000 Cat 8 with plots ~12,000 Cat 6A with plots |
Level V Accuracy | 1 GHz |
2G Accuracy | 2 GHz |
Resistance Unbalance Measurement | Yes |
Shield Integrity Check | Yes |
TCL Measurement | Yes |
ELTCTL Measurement | Yes |
CDNEXT Measurement | Yes |
CMRL Measurement | Yes |
Built in Alien XTalk Module | Yes |
Channel Adapter | 2 GHz Range |
Permanent Link Adapter | 2 GHz Range |
Environmental | |
Operating Temperature | 32°F to 113°F (0°C to 45°C) |
Storage Temperature | -22°F to 140°F (-30°C to 60°C) |
Operating Relative Humidity (% RH Without Condensation) | 0% to 90%, 32°F to 95°F (0°C to 35°C) 0% to 70%, 95°F to 113°F (35°C to 45°C) |
Vibration | Random, 2 g, 5 Hz-500 Hz |
Shock | 1 m drop test with and without module and adapter |
Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
Operating Altitude | 13,123 ft (4,000 m) 10,500 ft (3,200 m) with AC Adapter |
EMC | EN 61326-1 |
General Specifications | |
Autotest Time | Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds |
Support Test Parameters | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
Display | 5.7 in LCD display with a projected capacitance touchscreen |
Case | High impact plastic with show absorbing overmold |
Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
Main Unit and Remote | Lithium ion battery pack, 7.2 V |
Typical Battery Life | 8 hours |
Charge time | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity |
Languages Supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian |
Calibration | Service center calibration period is 1 year |
Versiv Mainframe and Accessories:
DSX CableAnalyzer:
CertiFiber Pro Quad OLTS:
OptiFiber Pro Quad OTDR:
Fiber Inspection and Cleaning:
Click on a category to view a selection of compatible accessories with the Fluke Networks DSX2-8000-PRO-W 2GHZ Pro Kit with WiFi, DSX, CFP, OFP, INSPC.