TSI/Alnor PAN231 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 220 to 240 V

Model: PAN231

TSI/Alnor PAN231 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 220 to 240 V

Model: PAN231

Use this PANDA system to test air ducts for leaks. The system features a high-flow fan and comes with an air velocity meter and micromanometer.

Use this PANDA system to test air ducts for leaks. The system features a high-flow fan and comes with an air velocity meter and micromanometer.

Sale Price $9792.00 USD
Regular Price $10880.00 USD
Availability Currently Not Available
Quantity

TSI/Alnor PAN231 Offers



With this TSI/Alnor PAN231 Positive and Negative Duct Accreditation (PANDA) System, you can easily test ductwork for leakage. By finding and fixing duct leaks, you'll help save energy in your buildings. The high-flow fan is capable of handling large sections of ductwork, while the VelociCalc meter lets you measure temperature, barometric pressure and volume flow.

Features

  • Perform positive and negative duct leakage testing in 1 complete system
  • Makes it easy to locate and fix duct leaks
  • Includes TSI/Alnor 9565-P VelociCalc ventilation meter and 5815 DP-Calc micromanometer to capture measurements
  • Use the 9565-P ventilation meter to calculate volume flow, temperature and barometric pressure measurements
  • 5815 micromanometer is capable of capturing pressure measurements
  • Features a high-flow fan to test large sections of ductwork
  • Unit fits comfortably in the back of vans and trucks
  • Delivers pass/fail reporting standards for SMACNA HVAC/R Air Duct Leakage Test Manual, EN12237 Ventilation for Buildings, EN1507 Ventilation for Buildings and EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution System

TSI/Alnor PAN231 Specifications


Pressure Measurement5815: ±15" W.G. (±3,735 Pa), 9565-P: 20.36 to 36.648 inHg (690 to 1,241 hPa) barometric
Volume Flow MeasurementHigh leakage range: 21 to 424 cfm (10 to 200 L/s), 36 to 720 m³/hr, low leakage range: 2 to 27.5 cfm (1 to 13 L/s), 3.6 to 46.9 m³/hr
Temperature Measurement-40 to 1,200°F (-40 to 650°C)
Actual Duct Static Range±10" W.G. (±2,500 Pa) at zero flow
AccuracyPressure Management: 1% of reading ±0.005" W.G. (±1 Pa), Volume Flow Measurement: ±2.5% of reading or ±0.02 cfm (±0.01 L/s, ±0.04m³/hr), whichever is greater, Temperature Measurement: ±0.1% of reading ±2°F (±0.056% of reading ±1.1°C), Barometric Pressure Measurement: ±2% of reading
Power Supply220 to 240 V, 1 phase, 50/60 Hz, 10 A
Product Length44.5" (1,130 mm)
Product Width26" (660 mm)
Product Height20" (510 mm)
Product Weight121 lbs (55 kg)
Click here for complete specifications on the TSI/Alnor PAN231

What's included with the TSI/Alnor PAN231


  • 9565-P VelociCalc Meter
  • 5815 DP-Calc Micromanometer

Ask a question about TSI/Alnor PAN231 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 220 to 240 V

Customer Reviews for the TSI/Alnor PAN231

TSI/Alnor PAN231 Offers



With this TSI/Alnor PAN231 Positive and Negative Duct Accreditation (PANDA) System, you can easily test ductwork for leakage. By finding and fixing duct leaks, you'll help save energy in your buildings. The high-flow fan is capable of handling large sections of ductwork, while the VelociCalc meter lets you measure temperature, barometric pressure and volume flow.

Features

  • Perform positive and negative duct leakage testing in 1 complete system
  • Makes it easy to locate and fix duct leaks
  • Includes TSI/Alnor 9565-P VelociCalc ventilation meter and 5815 DP-Calc micromanometer to capture measurements
  • Use the 9565-P ventilation meter to calculate volume flow, temperature and barometric pressure measurements
  • 5815 micromanometer is capable of capturing pressure measurements
  • Features a high-flow fan to test large sections of ductwork
  • Unit fits comfortably in the back of vans and trucks
  • Delivers pass/fail reporting standards for SMACNA HVAC/R Air Duct Leakage Test Manual, EN12237 Ventilation for Buildings, EN1507 Ventilation for Buildings and EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution System

TSI/Alnor PAN231 Specifications


Pressure Measurement5815: ±15" W.G. (±3,735 Pa), 9565-P: 20.36 to 36.648 inHg (690 to 1,241 hPa) barometric
Volume Flow MeasurementHigh leakage range: 21 to 424 cfm (10 to 200 L/s), 36 to 720 m³/hr, low leakage range: 2 to 27.5 cfm (1 to 13 L/s), 3.6 to 46.9 m³/hr
Temperature Measurement-40 to 1,200°F (-40 to 650°C)
Actual Duct Static Range±10" W.G. (±2,500 Pa) at zero flow
AccuracyPressure Management: 1% of reading ±0.005" W.G. (±1 Pa), Volume Flow Measurement: ±2.5% of reading or ±0.02 cfm (±0.01 L/s, ±0.04m³/hr), whichever is greater, Temperature Measurement: ±0.1% of reading ±2°F (±0.056% of reading ±1.1°C), Barometric Pressure Measurement: ±2% of reading
Power Supply220 to 240 V, 1 phase, 50/60 Hz, 10 A
Product Length44.5" (1,130 mm)
Product Width26" (660 mm)
Product Height20" (510 mm)
Product Weight121 lbs (55 kg)
Click here for complete specifications on the TSI/Alnor PAN231

What's included with the TSI/Alnor PAN231


  • 9565-P VelociCalc Meter
  • 5815 DP-Calc Micromanometer

Ask a question about TSI/Alnor PAN231 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 220 to 240 V

Customer Reviews for the TSI/Alnor PAN231

More TSI/Alnor Products

Calibration Lab