Capture longer time periods at higher resolutions with this oscilloscope that has a 28 Mpts record length. In addition, the dual-channel design can achieve a maximum sampling rate of 1 GS/s per channel.
Capture longer time periods at higher resolutions with this oscilloscope that has a 28 Mpts record length. In addition, the dual-channel design can achieve a maximum sampling rate of 1 GS/s per channel.
Accurately measure waveforms with this oscilloscope. Capture longer time periods at higher resolutions with the 28 Mpts record length, while the dual-channel design can achieve a maximum sampling rate of 1 GS/s per channel. In addition, the 400,000 wfm/s waveform capture rate captures unusual or low-probability events, and the Gate and Zoom measurements enhance the waveform data's flexibility and validity.
Features
Record length up to 28 Mpts
Using hardware-based Zoom technology the maximum record length of up to 28 Mpts, users are able to over-sample to capture longer time periods at higher resolution and use the zoom feature to see more details within each signal.
Excellent sampling rate
Two channel series have one 1 GSa/s or 2 GSa/s ADC, depending on the model. When all channels are enabled, each channel has a maximum sample rate of 500 Msa/s or 1 GSa/s depending on the model. When a single channel per ADC is active, it has sample rate of 1 GSa/s or 2 GSa/s depending on the model. Four channel series have two 1 GSa/s ADCs. When all channels are enabled, each channel has a maximum sample rate of 500 MSa/s. When a single channel per ADC is active, it has a sample rate of 1 GSa/s.
Advanced waveform capture rates
With a waveform capture rate of up to 400,000 wfm/s (sequence mode), this oscilloscope can easily capture the unusual or low-probability events.
New generation of high speed display technology
Math functions
FFT, addition, subtraction, multiplication, division, integration, differential, square root which enables speedy extraction of results from waveforms and measurements.
256-level intensity grading and color temperature display
Display technology provides for fast refresh rates. The resulting intensity-graded trace is brighter for events that occur with more frequency and dims when the events occur with less frequency
Automatic measurements
Up to 38 parameters which include Measurement Statistics, Zoom, Gating, Math, History and Reference functions.
History waveforms (history) mode and segmented acquisition (sequence)
Playback the latest triggered events using the history function. Segmented memory collection will store trigger events into multiple (up to 80,000) memory segments. Each segment will store triggered waveforms and timestamp each frame.
Gate and zoom measurement
Through Gate and Zoom measurement, the user can specify an arbitrary interval of waveform data analysis and statistics. This helps avoid measurement errors that can be caused by invalid or extraneous data, greatly enhancing the measurements’ validity and flexibility.
Multiple interface types
USB Host, USB Device (USB-TMC), LAN, Trigger Out thus allowing users to save data for external analysis and screen images for reports.
Bandwidth | 200 MHz |
Sampling Rate (Maximum) | The A series has a single 2 GSa/s ADC When both channels are enabled, each channel has a maximum sample rate of 1 GSa/s When a single channel is active, that channel has sample rate of 2 GSa/s |
Channels | 2+EXT |
Memory Depth (Maximum) | 14 Mpts/CH (not interleave mode) 28 Mpts/CH (interleave mode) |
Waveform Capture Rate (Maximum) | 100,000 wfm/s (normal mode) 400,000 wfm/s (sequence mode) |
Trigger Type | Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, Video |
Serial Trigger and Decoder (Standard) | IIC, SPI, UART/RS232, CAN, LIN |
16 Digital Channels | Maximum waveform capture rate up to 1 GSa/s Record length up to 14 Mpts/CH |
USB AWG Module | Isolated, single channel, 25 MHz, sample rate of 125 MHz, wave length of 16 kpts |
Bode Plot | Minimum start frequency of 10 Hz Minimum scan bandwidth of 500 Hz Maximum scan bandwidth of 120 MHz 500 maximum scan frequency points |
I/O | USB Host, USB Device, LAN, Pass/Fail, Trigger Out, Sbus (Teledyne Test Tools MSO) |
Probe (Std) | 2 pcs passive probe |
Display | 7" (17.76 cm) TFT-LCD (800 x 480) |
Weight | Without package: 5.73 lbs (2.6 kg) With package 8.38 lbs (3.8 kg) |
Click on a category to view a selection of compatible accessories with the Teledyne LeCroy T3DSO1202A Oscilloscope, 2 channels, 1 GS/s.
Bandwidth | 200 MHz |
Sampling Rate (Maximum) | The A series has a single 2 GSa/s ADC When both channels are enabled, each channel has a maximum sample rate of 1 GSa/s When a single channel is active, that channel has sample rate of 2 GSa/s |
Channels | 2+EXT |
Memory Depth (Maximum) | 14 Mpts/CH (not interleave mode) 28 Mpts/CH (interleave mode) |
Waveform Capture Rate (Maximum) | 100,000 wfm/s (normal mode) 400,000 wfm/s (sequence mode) |
Trigger Type | Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, Video |
Serial Trigger and Decoder (Standard) | IIC, SPI, UART/RS232, CAN, LIN |
16 Digital Channels | Maximum waveform capture rate up to 1 GSa/s Record length up to 14 Mpts/CH |
USB AWG Module | Isolated, single channel, 25 MHz, sample rate of 125 MHz, wave length of 16 kpts |
Bode Plot | Minimum start frequency of 10 Hz Minimum scan bandwidth of 500 Hz Maximum scan bandwidth of 120 MHz 500 maximum scan frequency points |
I/O | USB Host, USB Device, LAN, Pass/Fail, Trigger Out, Sbus (Teledyne Test Tools MSO) |
Probe (Std) | 2 pcs passive probe |
Display | 7" (17.76 cm) TFT-LCD (800 x 480) |
Weight | Without package: 5.73 lbs (2.6 kg) With package 8.38 lbs (3.8 kg) |
Click on a category to view a selection of compatible accessories with the Teledyne LeCroy T3DSO1202A Oscilloscope, 2 channels, 1 GS/s.