Based on a combination of Hall effect and transformer technology, this probe is ideal for accurate AC, DC, and impulse current measurements. It does not require circuit breakage or shunt insertion to make an accurate and reliable current measurement. Features a bandwidth of 50 MHz and a maximum continuous input current of 30A.
Based on a combination of Hall effect and transformer technology, this probe is ideal for accurate AC, DC, and impulse current measurements. It does not require circuit breakage or shunt insertion to make an accurate and reliable current measurement. Features a bandwidth of 50 MHz and a maximum continuous input current of 30A.
This current probe does not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, this current probe is ideal for making accurate AC, DC, and impulse current measurements.
Features
High Sensitivity
Provides a high sensitivity of 1mA/div. This allows for more precise low current measurements on oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis.
Fully Integrated
Powered through the ProBus connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for the Degauss and Autozero functions to be done directly from the oscilloscope's user interface.
Deskew Calibration Source
The DSC015 deskew calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes.
Applications
Design and test of:
Electrical | |
Bandwidth (Probe Only) | 50 MHz |
Coupling | AC 1 MΩ, DC 1MΩ, GND |
Rise Time (typical) | 7 ns |
Maximum Continuous Input Current | 30 A |
Maximum Peak Current (non-continuous) | 50 A |
Minimum Sensitivity | 1 mA/div |
Amplitude Accuracy | ±1% of reading to 30 A ±2% of reading to 50 A |
Maximum Circuit Voltage | 300 V, CAT I (insulated wire) |
Environmental and Safety | |
Operating Temperature | 32 to 104°F (0 to 40°C) |
Storage Temperature | 14 to 122°F (-10 to 50°C) |
Humidity | ≤80 % relative humidity (non-condensing) |
Maximum Altitude | 2000 m |
General Specifications | |
Dimensions (Probe Head) | 6.89 x 0.71 x 1.57" (175 x 18 x 40 mm) |
Cable Length | 1.5 m |
Maximum Conductor Size | 0.19" (5 mm) |
Weight | 0.57 lb (260 g) |
Electrical | |
Bandwidth (Probe Only) | 50 MHz |
Coupling | AC 1 MΩ, DC 1MΩ, GND |
Rise Time (typical) | 7 ns |
Maximum Continuous Input Current | 30 A |
Maximum Peak Current (non-continuous) | 50 A |
Minimum Sensitivity | 1 mA/div |
Amplitude Accuracy | ±1% of reading to 30 A ±2% of reading to 50 A |
Maximum Circuit Voltage | 300 V, CAT I (insulated wire) |
Environmental and Safety | |
Operating Temperature | 32 to 104°F (0 to 40°C) |
Storage Temperature | 14 to 122°F (-10 to 50°C) |
Humidity | ≤80 % relative humidity (non-condensing) |
Maximum Altitude | 2000 m |
General Specifications | |
Dimensions (Probe Head) | 6.89 x 0.71 x 1.57" (175 x 18 x 40 mm) |
Cable Length | 1.5 m |
Maximum Conductor Size | 0.19" (5 mm) |
Weight | 0.57 lb (260 g) |