Kanomax 3522 Piezobalance Dust Monitor, <2.5 μm

Model: 3522

Kanomax 3522 Piezobalance Dust Monitor, <2.5 μm

Model: 3522

Work with this unique Piezobalance dust monitor to get direct mass concentration of particulates using Piezobalance technology, unlike conventional dust meters. Ideal especially for oil mist monitoring, it is equipped with a 2.5 μm impactor.

Work with this unique Piezobalance dust monitor to get direct mass concentration of particulates using Piezobalance technology, unlike conventional dust meters. Ideal especially for oil mist monitoring, it is equipped with a 2.5 μm impactor.

Regular Price $3500.00 USD
Availability 2 to 3 Weeks
Quantity

Kanomax 3522 Offers

As air samples enter the system, it travels through the impactor, which captures and removes larger particulates away from the sample. Smaller particulates become electrically charged and deposited on teh piezo-crystal. The total mass of the deposited particulates affects the piezo-crystals frequency. Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained.

Features

  • Datalogging ability allows user to log 500 samples
  • Simple cleaning mechanism for easy maintenance
  • RS232C port available as standard
  • Back-lit display is easy to read in poor lighting conditions
  • Measuring object: Airborne particle counter <2.5 μm
  • Impactor: 2.5 μm
  • Measuring Range: 0.01 to 10 mg/m3
  • Sampling flow rate: 1 L/minute
  • Accuracy: ±10% of reading ±1 digit (0 to 5 mg/m3) and ±20% of reading ±1 digit (5 to 10 mg/m3)
  • Data logging: 500 data and time stamped measurements
  • Digital Output: RS-232C
  • Power supply: AC or Ni-MH battery

Benefits

  • While conventional dust meters "count" particulates, the Piezobalance dust meter "weighs" mass concentration of particulates
  • Data can be reviewed on-screen, printed or downloaded to a computer
  • Software included for easy data download and processing
  • Easy operation requires no special training

Applications

  • IAQ investigations
  • Environmental measurements
  • Product quality control
  • Laboratory research

Kanomax 3522 Specifications

Measuring Object: Airborne particulate matter <2.5 μm
Range: 0.02 to 10 mg/m3
Time: Preset: 120 or 24 seconds; Manual: 10 to 3600 seconds
Sampling Flow Rate 1 L/minute
Accuracy ±10% of rdg ±1 digit (0 to 5 mg / m3)
±20% of rdg ±1 digit (5 to 10 mg / m3)
Cleaning Frequency Cleaning is required after every 10 to 20 measurements
"CLEANING" will appear on the display when it needs to be cleaned
Data Logging Maximum 500 date and time stamped samples
Digital Output (To PC or printer) RS232C (Baud Rates 4800, 9600, and 19,200)
Power Supply AC (85 to 240 V) or DC Ni-MH battery
Dimensions 2.6 x 5.9 x 7.1" (65 x 150 x 180 mm)
Weight Approximately 4.4 lbs (2 kg)
Click here for complete specifications on the Kanomax 3522

What's included with the Kanomax 3522

  • Kanomax 3522 Piezobalance Dust Monitor, <2.5 μm

Ask a question about Kanomax 3522 Piezobalance Dust Monitor, <2.5 μm

Customer Reviews for the Kanomax 3522

Kanomax 3522 Offers

As air samples enter the system, it travels through the impactor, which captures and removes larger particulates away from the sample. Smaller particulates become electrically charged and deposited on teh piezo-crystal. The total mass of the deposited particulates affects the piezo-crystals frequency. Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained.

Features

  • Datalogging ability allows user to log 500 samples
  • Simple cleaning mechanism for easy maintenance
  • RS232C port available as standard
  • Back-lit display is easy to read in poor lighting conditions
  • Measuring object: Airborne particle counter <2.5 μm
  • Impactor: 2.5 μm
  • Measuring Range: 0.01 to 10 mg/m3
  • Sampling flow rate: 1 L/minute
  • Accuracy: ±10% of reading ±1 digit (0 to 5 mg/m3) and ±20% of reading ±1 digit (5 to 10 mg/m3)
  • Data logging: 500 data and time stamped measurements
  • Digital Output: RS-232C
  • Power supply: AC or Ni-MH battery

Benefits

  • While conventional dust meters "count" particulates, the Piezobalance dust meter "weighs" mass concentration of particulates
  • Data can be reviewed on-screen, printed or downloaded to a computer
  • Software included for easy data download and processing
  • Easy operation requires no special training

Applications

  • IAQ investigations
  • Environmental measurements
  • Product quality control
  • Laboratory research

Kanomax 3522 Specifications

Measuring Object: Airborne particulate matter <2.5 μm
Range: 0.02 to 10 mg/m3
Time: Preset: 120 or 24 seconds; Manual: 10 to 3600 seconds
Sampling Flow Rate 1 L/minute
Accuracy ±10% of rdg ±1 digit (0 to 5 mg / m3)
±20% of rdg ±1 digit (5 to 10 mg / m3)
Cleaning Frequency Cleaning is required after every 10 to 20 measurements
"CLEANING" will appear on the display when it needs to be cleaned
Data Logging Maximum 500 date and time stamped samples
Digital Output (To PC or printer) RS232C (Baud Rates 4800, 9600, and 19,200)
Power Supply AC (85 to 240 V) or DC Ni-MH battery
Dimensions 2.6 x 5.9 x 7.1" (65 x 150 x 180 mm)
Weight Approximately 4.4 lbs (2 kg)
Click here for complete specifications on the Kanomax 3522

What's included with the Kanomax 3522

  • Kanomax 3522 Piezobalance Dust Monitor, <2.5 μm

Ask a question about Kanomax 3522 Piezobalance Dust Monitor, <2.5 μm

Customer Reviews for the Kanomax 3522