TSI/Alnor EBT731 Balometer Capture Hood

Model: EBT731

TSI/Alnor EBT731 Balometer Capture Hood

Model: EBT731

The Balometer® Capture Hood is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings at diffusers and grilles.

The Balometer® Capture Hood is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings at diffusers and grilles.

This product exceeds standard shipping dimensions/weight, as such it does not qualify for free shipping. We will contact you with your shipping costs.

Sale Price $3339.00 USD
Regular Price $3710.00 USD
Availability 2 in Stock
Quantity

TSI/Alnor EBT731 Offers

Primarily used for efficiently taking direct air volume readings at diffusers and grilles, this capture hood kit features a detachable micromanometer which can be used with optional probes (sold separately) for increased flexibility in multiple measurement applications.

Capture hood features

  • Ergonomic, lightweight design enables easy one-person operation
  • Automatic sensing and display of supply or return flows saves time on the job
  • Back pressure compensation ensures accurate readings at high flow rates
  • Detachable digital micromanometer provides additional measurement capability
  • Multiple hood size options enable measurement of different outlet dimensions
  • Compatible LogDat Mobile Remote Reader and Data Logger Software option simplifies documenting of results and emailing of reports
  • Capture hood stand eliminates the need for ladders (reaching diffusers up to 15' [4.5 m])

Micromanometer features

  • Accurate measurement of pressure, velocity and flow complies with industry standards
  • Auto-zeroing pressure sensor reduces user-steps and saves time
  • Automatic density correction increases reading accuracy
  • Large, backlit graphic display offers easy-to-use interface - up to five simultaneous measurements, on-screen messages and instructions, multi-language capability
  • Intuitive menu structure for easy operation
  • Integrated Log-Tchebycheff duct traverse mapping application simplifies calculations
  • Bluetooth bi-directional communication eases data transfer and permits use of LogDat Mobile Remote Reader and Data Logger Software for Android devices

Applications

  • Test and balance
  • Commissioning
  • Facilities management
  • Health and safety
  • Ventilation system
  • HVAC/R

TSI/Alnor EBT731 Specifications

Velocity Range
Pitot Probes 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe 25 to 5000 ft/min (0.125 to 25 m/s)
Velocity Matrix 25 to 2500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities
>50 ft/min (>0.25 m/s)
Units ft/min, m/s
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 inH2O (±3735 Pa); 150 inH2O (37.5 kPa), maximum safe operating pressure
Absolute Pressure 15 to 40 inHg (356 to 1016 mmHg)
Accuracy ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential; ±2% of reading absolute
Units inH2O, inHg, Pa, hPa, kPa, mmHg, cmHg, mmH2O, cmH2O
Resolution 0.00001 inH2O (0.001 Pa) static and differential; 0.01 inHg (1 mmHg) absolute
Volume
Range 25 to 2500 ft3/min (42 to 4250 m3/h) capture hood, supply and return
Accuracy ±3% of reading ±7 ft3/min (±12 m3/h) at flows >50 ft3/min (>85 m3/h)
Units ft3/min, m3/h, m3/min, l/s
Resolution 1 ft3/min (1 m3/h)
RH
Range 5 to 95% RH (Temperature/RH Probe)
Accuracy ±3% RH
Resolution 0.1% RH
Temperature
Sensor in Base 40 to 140°F (4.4 to 60°C)
Temperature/RH Probe 14 to 140°F (-10 to 60°C)
Accuracy ±0.5°F (±0.3°C)
Units °F, °C
Resolution 0.1°F (0.1°C)
Instrument Temperature Range
Operating 40 to 140°F (4.4 to 60°C)
Storage -4 to 160°F (-20 to 71°C)
General Specifications
Statistics Minimum, maximum, average, and sum
Data Storage 25,500 samples, times, and date stamped
Logging Interval User Selectable
Response Time 2 to 8 seconds, differential pressure sensor
Power Requirements 4 x AA Cells or AC adapter
Dimensions 7.4 x 4.5 x 2.3" (18.8 x 11.4 x 5.8 cm)
Weight 7.4 lbs (3.4 kg)
Click here for complete specifications on the TSI/Alnor EBT731

What's included with the TSI/Alnor EBT731

  • Capture Hood Base with Poles, Frame and Fabric
  • Micromanometer
  • 2 x Calibration Certificates (Pressure and Flow)
  • 6 x Support Poles
  • Pitot Probe
  • 2 x Static Pressure Probes
  • Tubing
  • Neck Strap
  • Wheeled Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • 2 x Battery Holders
  • Multi-Country AC Power Adaptor
  • User Manual
  • LogDat CH Downloading Software with Cable

Click on a category to view a selection of compatible accessories with the TSI/Alnor EBT731 Balometer Capture Hood.

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-60 Stainless Steel Pitot Tube (5/16" dia. X 60"L) 160-60
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-36 Stainless Steel Pitot Tube (5/16" dia. X 36"L) 160-36
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-24 Stainless Steel Pitot Tube (5/16" dia. X 24"L) 160-24
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-18 Stainless Steel Pitot Tube (5/16" dia. X 18"L) 160-18
No calibration needed. Precisely located, burr-free static pressure holes.








TSI/Alnor 801207 Hood Expansion Kit for the EBT731, 1 x 5' and 3 x 3' 801207
For use with the EBT731 Balometer Capture Hood.




TSI/Alnor 801090 16 Point Velocity Matrix Add On Kit with Telescopic Handle 801090
Grid covers 1 ft2 (0.09 m2) and averages the air velocity while minimizing the effects of turbulence to produce a stable reading.




TSI/Alnor 800187 Air Flow Probe, 18" 800187
For use with the EBT731.




Ask a question about TSI/Alnor EBT731 Balometer Capture Hood

Customer Reviews for the TSI/Alnor EBT731

TSI/Alnor EBT731 Offers

Primarily used for efficiently taking direct air volume readings at diffusers and grilles, this capture hood kit features a detachable micromanometer which can be used with optional probes (sold separately) for increased flexibility in multiple measurement applications.

Capture hood features

  • Ergonomic, lightweight design enables easy one-person operation
  • Automatic sensing and display of supply or return flows saves time on the job
  • Back pressure compensation ensures accurate readings at high flow rates
  • Detachable digital micromanometer provides additional measurement capability
  • Multiple hood size options enable measurement of different outlet dimensions
  • Compatible LogDat Mobile Remote Reader and Data Logger Software option simplifies documenting of results and emailing of reports
  • Capture hood stand eliminates the need for ladders (reaching diffusers up to 15' [4.5 m])

Micromanometer features

  • Accurate measurement of pressure, velocity and flow complies with industry standards
  • Auto-zeroing pressure sensor reduces user-steps and saves time
  • Automatic density correction increases reading accuracy
  • Large, backlit graphic display offers easy-to-use interface - up to five simultaneous measurements, on-screen messages and instructions, multi-language capability
  • Intuitive menu structure for easy operation
  • Integrated Log-Tchebycheff duct traverse mapping application simplifies calculations
  • Bluetooth bi-directional communication eases data transfer and permits use of LogDat Mobile Remote Reader and Data Logger Software for Android devices

Applications

  • Test and balance
  • Commissioning
  • Facilities management
  • Health and safety
  • Ventilation system
  • HVAC/R

TSI/Alnor EBT731 Specifications

Velocity Range
Pitot Probes 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe 25 to 5000 ft/min (0.125 to 25 m/s)
Velocity Matrix 25 to 2500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities
>50 ft/min (>0.25 m/s)
Units ft/min, m/s
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 inH2O (±3735 Pa); 150 inH2O (37.5 kPa), maximum safe operating pressure
Absolute Pressure 15 to 40 inHg (356 to 1016 mmHg)
Accuracy ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential; ±2% of reading absolute
Units inH2O, inHg, Pa, hPa, kPa, mmHg, cmHg, mmH2O, cmH2O
Resolution 0.00001 inH2O (0.001 Pa) static and differential; 0.01 inHg (1 mmHg) absolute
Volume
Range 25 to 2500 ft3/min (42 to 4250 m3/h) capture hood, supply and return
Accuracy ±3% of reading ±7 ft3/min (±12 m3/h) at flows >50 ft3/min (>85 m3/h)
Units ft3/min, m3/h, m3/min, l/s
Resolution 1 ft3/min (1 m3/h)
RH
Range 5 to 95% RH (Temperature/RH Probe)
Accuracy ±3% RH
Resolution 0.1% RH
Temperature
Sensor in Base 40 to 140°F (4.4 to 60°C)
Temperature/RH Probe 14 to 140°F (-10 to 60°C)
Accuracy ±0.5°F (±0.3°C)
Units °F, °C
Resolution 0.1°F (0.1°C)
Instrument Temperature Range
Operating 40 to 140°F (4.4 to 60°C)
Storage -4 to 160°F (-20 to 71°C)
General Specifications
Statistics Minimum, maximum, average, and sum
Data Storage 25,500 samples, times, and date stamped
Logging Interval User Selectable
Response Time 2 to 8 seconds, differential pressure sensor
Power Requirements 4 x AA Cells or AC adapter
Dimensions 7.4 x 4.5 x 2.3" (18.8 x 11.4 x 5.8 cm)
Weight 7.4 lbs (3.4 kg)
Click here for complete specifications on the TSI/Alnor EBT731

What's included with the TSI/Alnor EBT731

  • Capture Hood Base with Poles, Frame and Fabric
  • Micromanometer
  • 2 x Calibration Certificates (Pressure and Flow)
  • 6 x Support Poles
  • Pitot Probe
  • 2 x Static Pressure Probes
  • Tubing
  • Neck Strap
  • Wheeled Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • 2 x Battery Holders
  • Multi-Country AC Power Adaptor
  • User Manual
  • LogDat CH Downloading Software with Cable

Click on a category to view a selection of compatible accessories with the TSI/Alnor EBT731 Balometer Capture Hood.

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-60 Stainless Steel Pitot Tube (5/16" dia. X 60"L) 160-60
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-36 Stainless Steel Pitot Tube (5/16" dia. X 36"L) 160-36
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-24 Stainless Steel Pitot Tube (5/16" dia. X 24"L) 160-24
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-18 Stainless Steel Pitot Tube (5/16" dia. X 18"L) 160-18
No calibration needed. Precisely located, burr-free static pressure holes.








TSI/Alnor 801207 Hood Expansion Kit for the EBT731, 1 x 5' and 3 x 3' 801207
For use with the EBT731 Balometer Capture Hood.




TSI/Alnor 801090 16 Point Velocity Matrix Add On Kit with Telescopic Handle 801090
Grid covers 1 ft2 (0.09 m2) and averages the air velocity while minimizing the effects of turbulence to produce a stable reading.




TSI/Alnor 800187 Air Flow Probe, 18" 800187
For use with the EBT731.




Ask a question about TSI/Alnor EBT731 Balometer Capture Hood

Customer Reviews for the TSI/Alnor EBT731

More TSI/Alnor Products