Critical Environment YESPLUSLGA-A+ 15 Channel Indoor Air Quality Monitor

Model: YESPLUSLGA-A+ | Order No: YES-PLUS-LGA-A+

Critical Environment YESPLUSLGA-A+ 15 Channel Indoor Air Quality Monitor

Model: YESPLUSLGA-A+ | Order No: YES-PLUS-LGA-A+

Featuring a multi-gas air quality monitoring and information recording instrument that simultaneously measures and records up to fifteen sensors.

Featuring a multi-gas air quality monitoring and information recording instrument that simultaneously measures and records up to fifteen sensors.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Critical Environment YESPLUSLGA 15-channel IAQ Meter-

Critical Environment YESPLUSLGA 15-channel IAQ Meter

Model: YESPLUSLGA | Order No: YES-PLUS-LGA

Multi-gas air quality monitoring and information recording instrument that simultaneously measures and records up to 15 sensors. With more than 30 different plug and play sensors to select from, users can accurately monitor more within a single, easy to carry instrument.


Recommended Accessories


Critical Environment YESPLUSLGA-A+ Offers

The fifteen channel sensor capacity includes RH and temperature, allowing the YES Plus LGA to handle up to 12 additional plug & play sensors consisting of a maximum of eight electrochemical toxic gas or oxygen sensors, four high current draw sensors such as an infrared, PID or catalytic, and a remote YESDUST particulate sensor. The large, backlit, multi-line scrolling LCD display indicates the sensor types installed and measured values for each gas, battery status and more. The system utilizes a long life rechargeable NiMH battery pack providing more than 24-hours of run time, depending on sensor array installed. The user can also set one alarm level for each gas to activate the internal audible alarm. The system is housed in a rugged ABS enclosure with swivel handle to act as a stand support or for carrying the instrument.

An air sample from the target environment is delivered to the sensors through "active sampling" by the internal sample draw pump. More than a million data points can be logged and stored on a built-in SD flash card for convenience.

Features

  • For monitoring: Ammonia, Arsine, Carbon dioxide, Carbon monoxide, Chlorine, Chlorine dioxide, Ethylene, Ethylene oxide, Fluorine , Formaldehyde, Hydrogen, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Hydrogen sulphide, Methane, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulphur dioxide, TVOCs
  • 15 sensor capacity
  • >30 plug and play sensor choices
  • Extensive, easy to use menu system
  • Internal sample pump with inline filter
  • Rugged ABS enclosure with swivel handle acts as stand support
  • Large, backlit, multi-line, LCD display
  • Data logging to SD flash card
  • Menu control positive sampling
  • RoHS compliant circuit boards
  • Data logging software for collecting, analyzing and graphing data

Applications

  • Residential buildings
  • Commercial buildings
  • Hospitals
  • Schools
  • Airports
  • Research facilities
  • Parking garages

Critical Environment YESPLUSLGA-A+ Specifications

Gas Sensors Ammonia (NH3), Arsine (AsH3), Carbon dioxide (CO2), Carbon monoxide (CO), Chlorine (Cl2), Chlorine dioxide (ClO2), Ethylene (C2H4), Ethylene oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen chloride (HCl), Hydrogen cyanide (HCN), Hydrogen fluoride (HF), Hydrogen sulphide (H2S), Methane (CH4), Nitric oxide (NO), Nitrogen dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur dioxide (SO2), TVOCs
Sampling Mode Internal sample pump automatically draws in sample of target environment
Memory >1 million data points data logging to SD flash card (optional)
Recording 12 bit, multi-channel, user configurable with 2GB SD memory card slot
Display Back-lit, multi-line LCD alphanumeric display
Buttons 4 tactile push buttons for user access
Calibration Automated through keypad
Audible Alarm Internal alarm rated 80 dB at 4 ft (1.2 m), one set point adjustment, audible can be switched off through menu
Power Rechargeable 3.6 V NiMH battery pack with plug-in battery charger 100 to 240 V, 50 to 60 Hz
Continuous operation with plug-in wall adapter 6VDC, Class-III, 2 A DC max
Operating Temperature 41 to 122°F (5 to 50°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Certifications Conforms to RoHS compliant circuit boards; UL94 flammability rating
Enclosure Rugged ABS (UL94-HB rated) with multi-position, adjustable aluminum carrying handle/stand
Dimensions 10.0 x 3.5 x 7.0" (254 x 89 x 178 mm)
Weight 3.6 lbs (1.7 kg)
Click here for complete specifications on the Critical Environment YESPLUSLGA-A+

What's included with the Critical Environment YESPLUSLGA-A+

  • Monitor
  • CO2 Sensor
  • Carrying Case
  • Battery Charger
  • Rechargeable 3.6 V NiMH Battery Pack

Click on a category to view a selection of compatible accessories with the Critical Environment YESPLUSLGA-A+ 15 Channel Indoor Air Quality Monitor.

YES USB-AB56-MC0007 USB Interface Cable USB-AB56-MC0007
Use with the YES AIR and YES PLUS.




Ask a question about Critical Environment YESPLUSLGA-A+ 15 Channel Indoor Air Quality Monitor

Customer Reviews for the Critical Environment YESPLUSLGA-A+

Critical Environment YESPLUSLGA-A+ Offers

The fifteen channel sensor capacity includes RH and temperature, allowing the YES Plus LGA to handle up to 12 additional plug & play sensors consisting of a maximum of eight electrochemical toxic gas or oxygen sensors, four high current draw sensors such as an infrared, PID or catalytic, and a remote YESDUST particulate sensor. The large, backlit, multi-line scrolling LCD display indicates the sensor types installed and measured values for each gas, battery status and more. The system utilizes a long life rechargeable NiMH battery pack providing more than 24-hours of run time, depending on sensor array installed. The user can also set one alarm level for each gas to activate the internal audible alarm. The system is housed in a rugged ABS enclosure with swivel handle to act as a stand support or for carrying the instrument.

An air sample from the target environment is delivered to the sensors through "active sampling" by the internal sample draw pump. More than a million data points can be logged and stored on a built-in SD flash card for convenience.

Features

  • For monitoring: Ammonia, Arsine, Carbon dioxide, Carbon monoxide, Chlorine, Chlorine dioxide, Ethylene, Ethylene oxide, Fluorine , Formaldehyde, Hydrogen, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Hydrogen sulphide, Methane, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulphur dioxide, TVOCs
  • 15 sensor capacity
  • >30 plug and play sensor choices
  • Extensive, easy to use menu system
  • Internal sample pump with inline filter
  • Rugged ABS enclosure with swivel handle acts as stand support
  • Large, backlit, multi-line, LCD display
  • Data logging to SD flash card
  • Menu control positive sampling
  • RoHS compliant circuit boards
  • Data logging software for collecting, analyzing and graphing data

Applications

  • Residential buildings
  • Commercial buildings
  • Hospitals
  • Schools
  • Airports
  • Research facilities
  • Parking garages

Critical Environment YESPLUSLGA-A+ Specifications

Gas Sensors Ammonia (NH3), Arsine (AsH3), Carbon dioxide (CO2), Carbon monoxide (CO), Chlorine (Cl2), Chlorine dioxide (ClO2), Ethylene (C2H4), Ethylene oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen chloride (HCl), Hydrogen cyanide (HCN), Hydrogen fluoride (HF), Hydrogen sulphide (H2S), Methane (CH4), Nitric oxide (NO), Nitrogen dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur dioxide (SO2), TVOCs
Sampling Mode Internal sample pump automatically draws in sample of target environment
Memory >1 million data points data logging to SD flash card (optional)
Recording 12 bit, multi-channel, user configurable with 2GB SD memory card slot
Display Back-lit, multi-line LCD alphanumeric display
Buttons 4 tactile push buttons for user access
Calibration Automated through keypad
Audible Alarm Internal alarm rated 80 dB at 4 ft (1.2 m), one set point adjustment, audible can be switched off through menu
Power Rechargeable 3.6 V NiMH battery pack with plug-in battery charger 100 to 240 V, 50 to 60 Hz
Continuous operation with plug-in wall adapter 6VDC, Class-III, 2 A DC max
Operating Temperature 41 to 122°F (5 to 50°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Certifications Conforms to RoHS compliant circuit boards; UL94 flammability rating
Enclosure Rugged ABS (UL94-HB rated) with multi-position, adjustable aluminum carrying handle/stand
Dimensions 10.0 x 3.5 x 7.0" (254 x 89 x 178 mm)
Weight 3.6 lbs (1.7 kg)
Click here for complete specifications on the Critical Environment YESPLUSLGA-A+

What's included with the Critical Environment YESPLUSLGA-A+

  • Monitor
  • CO2 Sensor
  • Carrying Case
  • Battery Charger
  • Rechargeable 3.6 V NiMH Battery Pack

Click on a category to view a selection of compatible accessories with the Critical Environment YESPLUSLGA-A+ 15 Channel Indoor Air Quality Monitor.

YES USB-AB56-MC0007 USB Interface Cable USB-AB56-MC0007
Use with the YES AIR and YES PLUS.




Ask a question about Critical Environment YESPLUSLGA-A+ 15 Channel Indoor Air Quality Monitor

Customer Reviews for the Critical Environment YESPLUSLGA-A+

More Critical Environment Products

Calibration Lab