Compact and performance-packed, this power controller provides an economical and versatile solid-state option for controlling electric heat. In addition, it is 200KA SCCR with proper fusing to minimize damage in the event of a short circuit and features a 277 to 600 V line/load voltage and a 4 to 20 mA DC control input.
Compact and performance-packed, this power controller provides an economical and versatile solid-state option for controlling electric heat. In addition, it is 200KA SCCR with proper fusing to minimize damage in the event of a short circuit and features a 277 to 600 V line/load voltage and a 4 to 20 mA DC control input.
Features
Applications
Operator Interface | Control input Input indication LED |
Amperage | Single-phase, see the output rating curve Maximum I2t for fusing: 4000 A2 sec Latching current: 400 mA maximum Holding current: 200 mA maximum Power dissipation is 1.2 W/A switched 200KA SCCR, Type 1 and 2 approved with the recommended fusing |
Line Voltage | 277 to 600 V Off-state leakage: 1 mA at 77°F (25°C) maximum 50/60 Hz independent |
Control Mode, Zero Cross | 4 to 20 mA DC input, variable time-base control output (3 cycles on, 3 cycles off at 50% power) |
Control Input | Loop powered linear current 4 to 20 mA DC: loop-powered, control option F0 only (requires current source with 8.0 V DC available, no more than two DIN-A-MITE inputs can be connected in series) |
Terminals | Control input: Compression: Will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire Line and load: Compression: Will accept 18 to 8 AWG (0.8 to 8.4 mm2) wire |
Operating Environment | -4 to 176°F (-20 to 80°C); see the output rating curve chart for your application 0 to 90% RH (relative humidity), non-condensing Insulation tested to 9842.52' (3000 m) Suitable for "Pollution degree 2" |
Agency Approvals | CE with proper filter: 204/108/EC electromagnetic compatibility directive EN 61326-1: Industrial immunity class A emissions 2006/95/EC low voltage directive EN 50178 safety requirements Installation category III, pollution degree 2 UL® 508 listed and C-UL® File E73741 2011/65/EU RoHS 2 |
Mounting | Options include DIN-rail or standard back panel mounting DIN EN 50022, 1.4 x 0.3" (35 x 7.5 mm) Mount cooling fins vertically |
Dimensions | 3.7 x 2 x 3.9" (94 x 50 x 98 mm) |
Weight | 0.71 lbs (0.32 kg) |
Operator Interface | Control input Input indication LED |
Amperage | Single-phase, see the output rating curve Maximum I2t for fusing: 4000 A2 sec Latching current: 400 mA maximum Holding current: 200 mA maximum Power dissipation is 1.2 W/A switched 200KA SCCR, Type 1 and 2 approved with the recommended fusing |
Line Voltage | 277 to 600 V Off-state leakage: 1 mA at 77°F (25°C) maximum 50/60 Hz independent |
Control Mode, Zero Cross | 4 to 20 mA DC input, variable time-base control output (3 cycles on, 3 cycles off at 50% power) |
Control Input | Loop powered linear current 4 to 20 mA DC: loop-powered, control option F0 only (requires current source with 8.0 V DC available, no more than two DIN-A-MITE inputs can be connected in series) |
Terminals | Control input: Compression: Will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire Line and load: Compression: Will accept 18 to 8 AWG (0.8 to 8.4 mm2) wire |
Operating Environment | -4 to 176°F (-20 to 80°C); see the output rating curve chart for your application 0 to 90% RH (relative humidity), non-condensing Insulation tested to 9842.52' (3000 m) Suitable for "Pollution degree 2" |
Agency Approvals | CE with proper filter: 204/108/EC electromagnetic compatibility directive EN 61326-1: Industrial immunity class A emissions 2006/95/EC low voltage directive EN 50178 safety requirements Installation category III, pollution degree 2 UL® 508 listed and C-UL® File E73741 2011/65/EU RoHS 2 |
Mounting | Options include DIN-rail or standard back panel mounting DIN EN 50022, 1.4 x 0.3" (35 x 7.5 mm) Mount cooling fins vertically |
Dimensions | 3.7 x 2 x 3.9" (94 x 50 x 98 mm) |
Weight | 0.71 lbs (0.32 kg) |