Veris PWXX04S Wet Media Differential Pressure Transducer, 0 to 100 psig, standard

Model: PWXX04S

Veris PWXX04S Wet Media Differential Pressure Transducer, 0 to 100 psig, standard

Model: PWXX04S

The wet media differential pressure transducer incorporates microprocessor profiled sensors for exceptional accuracy and reliability with 0 to 100 psig.

The wet media differential pressure transducer incorporates microprocessor profiled sensors for exceptional accuracy and reliability with 0 to 100 psig.

Sale Price $417.97 USD
Regular Price $467.00 USD
Availability 15+ Weeks
Quantity

Veris PWXX04S Offers

The wet media differential pressure transducer incorporates microprocessor profiled sensors for exceptional accuracy and reliability with 0 to 100 psig.

Features

  • Jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Jumper-controlled electronic surge dampening for high stability
  • Push-button zero calibration ensures there are no trim pots to adjust
  • Lowest total installed cost
  • Jumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed; simply change the jumper position from normal to swap and problem solved!
  • Dual sensor design eliminates the requirement for a bypass valve assembly in most applications
  • Switch-selectable pressure ranges means fewer models to order and stock
  • Push-button and remote zero adjustment help maintain accuracy and prevent callbacks with automatic zero calibration

Applications

  • Monitoring and Controlling Pump Differential Pressure
  • Chiller/Boiler Differential Pressure Drop
  • CW/HW System Differential Pressure

Veris PWXX04S Specifications

Input Power 12 to 30 VDC/24 VAC nominal
Maximum Current Draw DC: 125 mA; AC: 280 mA
Output 3-wire transmitter; user selectable 4 to 20 mA, (clipped and capped)/0 to 5 V/0 to 10 V
Surge Damping Electronic; 5-second averaging
Accuracy At 77°C (25°C): ±1% FS (range A, B, C), ±2% FS (range D)
Test Mode Overrides output to full-scale (20 mA, 5 V, 10 V)
Pressure Range (Selectable) 0 to 10/20/50/100 psid (0 to 0.34/0.69/1.72/3.45 bar)
Product Operating Environment -140 to 130°F (-10 to 55°C); 0 to 90% RH, non-condensing
Long Term Stability ±0.25% per year
Zero Adjust Push-button auto-zero and digital input (2-pos terminal block)
Status Indication Dual-color LED: green = normal, green blinking = low > high, red = over-range, red blinking = over-pressure
Housing Material White powder-coat aluminum
Media Compatibility Media compatible with 17 to 4 PH stainless steel
Proof Pressure Max 2 x FS range
Burst Pressure Max 5 x FS range
Temperature Compensated Range 32 to 122°F (0 to 50°C); TC Zero <±1.5% of product FS per sensor; TC Span<±1.5% of product FS per sensor (2 sensors per unit)
Media Temp Limits -4 to 185±F (-20 to 85±C); 0 to 90% RH non-condensing
Click here for complete specifications on the Veris PWXX04S

What's included with the Veris PWXX04S

  • Veris PWXX04S Wet Media Differential Pressure Transducer, 0 to 100 psig, standard

Ask a question about Veris PWXX04S Wet Media Differential Pressure Transducer, 0 to 100 psig, standard

Customer Reviews for the Veris PWXX04S

Veris PWXX04S Offers

The wet media differential pressure transducer incorporates microprocessor profiled sensors for exceptional accuracy and reliability with 0 to 100 psig.

Features

  • Jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Jumper-controlled electronic surge dampening for high stability
  • Push-button zero calibration ensures there are no trim pots to adjust
  • Lowest total installed cost
  • Jumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed; simply change the jumper position from normal to swap and problem solved!
  • Dual sensor design eliminates the requirement for a bypass valve assembly in most applications
  • Switch-selectable pressure ranges means fewer models to order and stock
  • Push-button and remote zero adjustment help maintain accuracy and prevent callbacks with automatic zero calibration

Applications

  • Monitoring and Controlling Pump Differential Pressure
  • Chiller/Boiler Differential Pressure Drop
  • CW/HW System Differential Pressure

Veris PWXX04S Specifications

Input Power 12 to 30 VDC/24 VAC nominal
Maximum Current Draw DC: 125 mA; AC: 280 mA
Output 3-wire transmitter; user selectable 4 to 20 mA, (clipped and capped)/0 to 5 V/0 to 10 V
Surge Damping Electronic; 5-second averaging
Accuracy At 77°C (25°C): ±1% FS (range A, B, C), ±2% FS (range D)
Test Mode Overrides output to full-scale (20 mA, 5 V, 10 V)
Pressure Range (Selectable) 0 to 10/20/50/100 psid (0 to 0.34/0.69/1.72/3.45 bar)
Product Operating Environment -140 to 130°F (-10 to 55°C); 0 to 90% RH, non-condensing
Long Term Stability ±0.25% per year
Zero Adjust Push-button auto-zero and digital input (2-pos terminal block)
Status Indication Dual-color LED: green = normal, green blinking = low > high, red = over-range, red blinking = over-pressure
Housing Material White powder-coat aluminum
Media Compatibility Media compatible with 17 to 4 PH stainless steel
Proof Pressure Max 2 x FS range
Burst Pressure Max 5 x FS range
Temperature Compensated Range 32 to 122°F (0 to 50°C); TC Zero <±1.5% of product FS per sensor; TC Span<±1.5% of product FS per sensor (2 sensors per unit)
Media Temp Limits -4 to 185±F (-20 to 85±C); 0 to 90% RH non-condensing
Click here for complete specifications on the Veris PWXX04S

What's included with the Veris PWXX04S

  • Veris PWXX04S Wet Media Differential Pressure Transducer, 0 to 100 psig, standard

Ask a question about Veris PWXX04S Wet Media Differential Pressure Transducer, 0 to 100 psig, standard

Customer Reviews for the Veris PWXX04S