Veris PW2LX05S Wet Media Differential Pressure Transducer, 0 to 250 psig, 17.24 barg

Model: PW2LX05S

Veris PW2LX05S Wet Media Differential Pressure Transducer, 0 to 250 psig, 17.24 barg

Model: PW2LX05S

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications. It incorporates microprocessor profiled sensors for exceptional accuracy and reliability.

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications. It incorporates microprocessor profiled sensors for exceptional accuracy and reliability.

Sale Price $534.32 USD
Regular Price $597.00 USD
Availability 6 to 7 Weeks
Quantity

Veris PW2LX05S Offers

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications. It incorporates microprocessor profiled sensors for exceptional accuracy and reliability.

Features

  • Jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Jumper-controlled electronic surge dampening for high stability
  • Push-button zero calibration ensures there are no trim pots to adjust
  • Lowest total installed cost
  • Jumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed; simply change the jumper position from normal to swap and problem solved!
  • Dual sensor design eliminates the requirement for a bypass valve assembly in most applications
  • Switch-selectable pressure ranges means fewer models to order and stock
  • Push-button and remote zero adjustment help maintain accuracy and prevent callbacks with automatic zero calibration

Applications

  • Monitoring and Controlling Pump Differential Pressure
  • Chiller/Boiler Differential Pressure Drop
  • CW/HW System Differential Pressure

Veris PW2LX05S Specifications

Input Power 12 to 24 VDC, loop powered
Maximum Current Draw 29 mA
Output 2-wire transmitter; user selectable 4 to 20 mA (clipped and capped)
Surge Damping Electronic; 5-second averaging
Accuracy At 77°C (25°C): ±1% FS (range A, B, C), ±2% FS (range D)
Test Mode Overrides output to full-scale (20 mA, 5 V, 10 V)
Pressure Range (Selectable) 0 to 10/20/50/100 psid (0 to 0.34/0.69/1.72/3.45 bar)
Product Operating Environment -140 to 130°F (-10 to 55°C); 0 to 90% RH, non-condensing
Long Term Stability ±0.25% per year
Zero Adjust Push-button auto-zero
Housing Material White powder-coat aluminum
Media Compatibility Media compatible with 17 to 4 PH stainless steel
Proof Pressure Max 2 x FS range
Burst Pressure Max 5 x FS range
Temperature Compensated Range 32 to 122°F (0 to 50°C); TC Zero <±1.5% of product FS per sensor; TC Span<±1.5% of product FS per sensor (2 sensors per unit)
Media Temp Limits -4 to 185±F (-20 to 85±C); 0 to 90% RH non-condensing
Click here for complete specifications on the Veris PW2LX05S

What's included with the Veris PW2LX05S

  • Veris PW2LX05S Wet Media Differential Pressure Transducer, 0 to 250 psig, 17.24 barg

Ask a question about Veris PW2LX05S Wet Media Differential Pressure Transducer, 0 to 250 psig, 17.24 barg

Customer Reviews for the Veris PW2LX05S

Veris PW2LX05S Offers

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications. It incorporates microprocessor profiled sensors for exceptional accuracy and reliability.

Features

  • Jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Jumper-controlled electronic surge dampening for high stability
  • Push-button zero calibration ensures there are no trim pots to adjust
  • Lowest total installed cost
  • Jumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed; simply change the jumper position from normal to swap and problem solved!
  • Dual sensor design eliminates the requirement for a bypass valve assembly in most applications
  • Switch-selectable pressure ranges means fewer models to order and stock
  • Push-button and remote zero adjustment help maintain accuracy and prevent callbacks with automatic zero calibration

Applications

  • Monitoring and Controlling Pump Differential Pressure
  • Chiller/Boiler Differential Pressure Drop
  • CW/HW System Differential Pressure

Veris PW2LX05S Specifications

Input Power 12 to 24 VDC, loop powered
Maximum Current Draw 29 mA
Output 2-wire transmitter; user selectable 4 to 20 mA (clipped and capped)
Surge Damping Electronic; 5-second averaging
Accuracy At 77°C (25°C): ±1% FS (range A, B, C), ±2% FS (range D)
Test Mode Overrides output to full-scale (20 mA, 5 V, 10 V)
Pressure Range (Selectable) 0 to 10/20/50/100 psid (0 to 0.34/0.69/1.72/3.45 bar)
Product Operating Environment -140 to 130°F (-10 to 55°C); 0 to 90% RH, non-condensing
Long Term Stability ±0.25% per year
Zero Adjust Push-button auto-zero
Housing Material White powder-coat aluminum
Media Compatibility Media compatible with 17 to 4 PH stainless steel
Proof Pressure Max 2 x FS range
Burst Pressure Max 5 x FS range
Temperature Compensated Range 32 to 122°F (0 to 50°C); TC Zero <±1.5% of product FS per sensor; TC Span<±1.5% of product FS per sensor (2 sensors per unit)
Media Temp Limits -4 to 185±F (-20 to 85±C); 0 to 90% RH non-condensing
Click here for complete specifications on the Veris PW2LX05S

What's included with the Veris PW2LX05S

  • Veris PW2LX05S Wet Media Differential Pressure Transducer, 0 to 250 psig, 17.24 barg

Ask a question about Veris PW2LX05S Wet Media Differential Pressure Transducer, 0 to 250 psig, 17.24 barg

Customer Reviews for the Veris PW2LX05S

More Veris Products

Calibration Lab