Veris H623-20 Current Transducer, 0 to 10 VDC analog output, 0 to 20 A

Model: H623-20

Veris H623-20 Current Transducer, 0 to 10 VDC analog output, 0 to 20 A

Model: H623-20

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current monitoring transducer has an amperage range of 0 to 20 A and provides accurate load trending information with a proportional 0 to 10 VDC output signal and monitored amperage range without jumpers.

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current monitoring transducer has an amperage range of 0 to 20 A and provides accurate load trending information with a proportional 0 to 10 VDC output signal and monitored amperage range without jumpers.

Sale Price $40.28 USD
Regular Price $45.00 USD
Availability 2 to 3 Weeks
Quantity

Veris H623-20 Offers

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current monitoring transducer has an amperage range of 0 to 20 A and provides accurate load trending information with a proportional 0 to 10 VDC output signal and monitored amperage range without jumpers.

Features

  • Self-powered analog current sensor, 0 to 10 VDC output
  • No jumpers on unit reduces installation error
  • No external power required for sensor
  • Factory calibrated
  • Mounting bracket included
  • 100% solid state, no moving parts to fail
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Fan/Pump Status

Veris H623-20 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 300 VAC RMS
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH, non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Maximum Wire Size 14 AWG
Terminal Block Torque (Nominal) 4 in-lbs (0.45 N-m)
Agency Approvals CE:EN61010-1:2001-02, CAT III, deg. 2, basic insulation
Click here for complete specifications on the Veris H623-20

What's included with the Veris H623-20

  • Veris H623-20 Current Transducer, 0 to 10 VDC analog output, 0 to 20 A

Ask a question about Veris H623-20 Current Transducer, 0 to 10 VDC analog output, 0 to 20 A

Customer Reviews for the Veris H623-20

Veris H623-20 Offers

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current monitoring transducer has an amperage range of 0 to 20 A and provides accurate load trending information with a proportional 0 to 10 VDC output signal and monitored amperage range without jumpers.

Features

  • Self-powered analog current sensor, 0 to 10 VDC output
  • No jumpers on unit reduces installation error
  • No external power required for sensor
  • Factory calibrated
  • Mounting bracket included
  • 100% solid state, no moving parts to fail
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Fan/Pump Status

Veris H623-20 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 300 VAC RMS
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH, non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Maximum Wire Size 14 AWG
Terminal Block Torque (Nominal) 4 in-lbs (0.45 N-m)
Agency Approvals CE:EN61010-1:2001-02, CAT III, deg. 2, basic insulation
Click here for complete specifications on the Veris H623-20

What's included with the Veris H623-20

  • Veris H623-20 Current Transducer, 0 to 10 VDC analog output, 0 to 20 A

Ask a question about Veris H623-20 Current Transducer, 0 to 10 VDC analog output, 0 to 20 A

Customer Reviews for the Veris H623-20

More Veris Products

Calibration Lab