The single-circuit, bi-directional DIN-mounted energy meter combines exceptional performance and easy installation to deliver a solution for power monitoring applications.
The single-circuit, bi-directional DIN-mounted energy meter combines exceptional performance and easy installation to deliver a solution for power monitoring applications.
The single-circuit, bi-directional DIN-mounted energy meter combines exceptional performance and easy installation to deliver a solution for power monitoring applications.
Features
Applications
Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
Control Power, DC | 3 W max.; UL and CE: 125 to 300 VDC (external DC current limiting required) |
Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
Scaling | 5 to 32,000 A |
Input Range | 0 to 0.333 V or 0 to 1 V (selectable); CTs must be rated for use with Class 1 voltage inputs |
Pulse Inputs (E5xHx and E50Fx Only) | Contact inputs to pulse accumulators (1 set with E5xH2 and E50F2; 2 sets with E5xH5 and E51F5) |
Real Power and Energy | 0.2% (ANSI C12.20, IEC 62053-22 Class 0.2S) |
Mounting Location | DIN Rail or 3-point screw mount |
Altitude of Operation | 9,842.5' (3,000 m) |
Operating Temperature Range | -22 to 158°F (-30 to 70°C) |
Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
Humidity Range | <95% RH non-condensing |
Mounting Location | Not suitable for wet locations; for indoor use only |
Warranty | 5 years limited |
Agency Approvals | UL 508 (Open Type Device), IEC/EN 61010-1, California CSI Solar, ANSI C12.20, Cat III, Pollution Degree 2 |
Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
Control Power, DC | 3 W max.; UL and CE: 125 to 300 VDC (external DC current limiting required) |
Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
Scaling | 5 to 32,000 A |
Input Range | 0 to 0.333 V or 0 to 1 V (selectable); CTs must be rated for use with Class 1 voltage inputs |
Pulse Inputs (E5xHx and E50Fx Only) | Contact inputs to pulse accumulators (1 set with E5xH2 and E50F2; 2 sets with E5xH5 and E51F5) |
Real Power and Energy | 0.2% (ANSI C12.20, IEC 62053-22 Class 0.2S) |
Mounting Location | DIN Rail or 3-point screw mount |
Altitude of Operation | 9,842.5' (3,000 m) |
Operating Temperature Range | -22 to 158°F (-30 to 70°C) |
Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
Humidity Range | <95% RH non-condensing |
Mounting Location | Not suitable for wet locations; for indoor use only |
Warranty | 5 years limited |
Agency Approvals | UL 508 (Open Type Device), IEC/EN 61010-1, California CSI Solar, ANSI C12.20, Cat III, Pollution Degree 2 |