The single-circuit, DIN-mounted energy meter with watt-hours pulse, VAR-hours pulse and alarm outputs is for use with series rope-style CTs. Complete with data logging: ten 16-bit configurable data buffers.
The single-circuit, DIN-mounted energy meter with watt-hours pulse, VAR-hours pulse and alarm outputs is for use with series rope-style CTs. Complete with data logging: ten 16-bit configurable data buffers.
The single-circuit, DIN-mounted energy meter with watt-hours pulse, VAR-hours pulse and alarm outputs is for use with series rope-style CTs. Complete with data logging: ten 16-bit configurable data buffers.
Features
Applications
Real Power and Energy | 0.5% (ANSI C12.20, IEC 62053-22 Class 0.5S) |
Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
Control Power, DC | 3 W max.; UL and CE: 125 to 300 Vdc (external DC current limiting required) |
Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
Current Input | 50 to 5,000 A |
Scaling Input Range | E683x series rope-style CTs only (CTs must be rated for connection to Class 1 voltage inputs) |
Pulse Inputs (E5xHxA and E50FxA Only) | Contact inputs to pulse accumulators (1 set with E5xH2A and E50F2A; 2 sets with E5xH5A and E51F5A) |
Operating Temperature Range | -22 to 158°F (-30 to 70°C) |
Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
Humidity Range | <95% RH non-condensing |
Mounting Location | Not suitable for wet locations; for indoor use only |
Warranty | 5 years limited |
Agency Approvals | UL 508, IEC/EN 61010-1, California CSI Solar, ANSI C12.20 |
Real Power and Energy | 0.5% (ANSI C12.20, IEC 62053-22 Class 0.5S) |
Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
Control Power, DC | 3 W max.; UL and CE: 125 to 300 Vdc (external DC current limiting required) |
Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
Current Input | 50 to 5,000 A |
Scaling Input Range | E683x series rope-style CTs only (CTs must be rated for connection to Class 1 voltage inputs) |
Pulse Inputs (E5xHxA and E50FxA Only) | Contact inputs to pulse accumulators (1 set with E5xH2A and E50F2A; 2 sets with E5xH5A and E51F5A) |
Operating Temperature Range | -22 to 158°F (-30 to 70°C) |
Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
Humidity Range | <95% RH non-condensing |
Mounting Location | Not suitable for wet locations; for indoor use only |
Warranty | 5 years limited |
Agency Approvals | UL 508, IEC/EN 61010-1, California CSI Solar, ANSI C12.20 |