Veris E34E28 Multi-Circuit/Multi-Circuit Meter, BACnet MST/TP, 28 x 3-phase meters

Model: E34E28

Veris E34E28 Multi-Circuit/Multi-Circuit Meter, BACnet MST/TP, 28 x 3-phase meters

Model: E34E28

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 28 x 3-phase meters or 24 channels.

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 28 x 3-phase meters or 24 channels.

Sale Price $5442.50 USD
Regular Price $6081.00 USD
Availability 2 to 3 Weeks
Quantity

Veris E34E28 Offers

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 28 x 3-phase meters or 24 channels.

Features

  • ANSI and IEC Class 0.5% accuracy, ideal for tenant billing
  • Low equipment and installation cost per metering points
  • Possibility to assign measurement channels as needed for the site: each channel can be assigned to a 3-phase, 2-phase or single-phase meter
  • (4) 3-phase meter E34 can be a (4) 3-phase meter, (8) 2-phase meter, (12) single-phase or any mix, like (1) 3-phase with neutral + (1) 3-phase + (2) 2-phase + (1) 1-phase meters which amounts to 12 channels equivalent to (4) 3-phase meters
  • Low-voltage current transformers (CTs) offer a safer and more accurate alternative to 5 A CTs and shorting blocks
  • Communications: The addition of Ethernet allows concurrent use of multiple protocol allowing E34E to report simultaneously to an Energy Management System (EMS), Building Management System (BMS) or an IT network monitoring system
  • Serial: Modbus RTU; Ethernet: BACnet MS/TP, Modbus TCP/RTU, BACnet IP and SNMP

Applications

  • Commercial and Residential Sub-Tenant Billing
  • Multi-Dwelling Units
  • Load-Based Cost Allocation
  • Overload Protection
  • Energy Management

Veris E34E28 Specifications

Measurement Voltage 90 to 300 VAC line-to-neutral, 50/60 Hz
Control Power 100 to 277 VAC line-to-neutral, 50/60 Hz, 15VA
Power/Energy IEC 62053-21 Class 0.5, ANSI C12.20 Class 0.5
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Current ±0.5% of reading from 2 to 100% full scale
Sampling Frequency 2,560 Hz
Update Rate 2 seconds (both panels)
Overload Capability 22 kAIC
Physical Interface 2-wire RS-485
Protocols Supported Modbus RTU or BACnet MSTP
Address 1 to 247 for Modbus RTU; 0 to 127 for BACnet MS/TP
Baud Rate 9600, 19200, 38400
Parity Modbus RTU: NONE, ODD, EVEN; BACnet MS/TP: NONE (fixed)
Physical Interface RJ45 connector with 10/100 Mbit Ethernet
Protocols Supported Modbus TCP, BACnet IP, SNMP V2c
Removable Connectors 4.4 to 5.3 in-lb (0.5 to 0.6 N-m)
Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
Storage Temperature -40 to 158°F (-40 to 70°C)
Altitude of Operation 9,842.5' (3,000 m)
Mounting Location Indoor use, dry location
Warranty 5 years limited
Agency Approvals IEC/EN61010-1
Installation Category Cat III, pollution degree 2
Click here for complete specifications on the Veris E34E28

What's included with the Veris E34E28

  • Veris E34E28 Multi-Circuit/Multi-Circuit Meter, BACnet MST/TP, 28 x 3-phase meters

Ask a question about Veris E34E28 Multi-Circuit/Multi-Circuit Meter, BACnet MST/TP, 28 x 3-phase meters

Customer Reviews for the Veris E34E28

Veris E34E28 Offers

The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 28 x 3-phase meters or 24 channels.

Features

  • ANSI and IEC Class 0.5% accuracy, ideal for tenant billing
  • Low equipment and installation cost per metering points
  • Possibility to assign measurement channels as needed for the site: each channel can be assigned to a 3-phase, 2-phase or single-phase meter
  • (4) 3-phase meter E34 can be a (4) 3-phase meter, (8) 2-phase meter, (12) single-phase or any mix, like (1) 3-phase with neutral + (1) 3-phase + (2) 2-phase + (1) 1-phase meters which amounts to 12 channels equivalent to (4) 3-phase meters
  • Low-voltage current transformers (CTs) offer a safer and more accurate alternative to 5 A CTs and shorting blocks
  • Communications: The addition of Ethernet allows concurrent use of multiple protocol allowing E34E to report simultaneously to an Energy Management System (EMS), Building Management System (BMS) or an IT network monitoring system
  • Serial: Modbus RTU; Ethernet: BACnet MS/TP, Modbus TCP/RTU, BACnet IP and SNMP

Applications

  • Commercial and Residential Sub-Tenant Billing
  • Multi-Dwelling Units
  • Load-Based Cost Allocation
  • Overload Protection
  • Energy Management

Veris E34E28 Specifications

Measurement Voltage 90 to 300 VAC line-to-neutral, 50/60 Hz
Control Power 100 to 277 VAC line-to-neutral, 50/60 Hz, 15VA
Power/Energy IEC 62053-21 Class 0.5, ANSI C12.20 Class 0.5
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Current ±0.5% of reading from 2 to 100% full scale
Sampling Frequency 2,560 Hz
Update Rate 2 seconds (both panels)
Overload Capability 22 kAIC
Physical Interface 2-wire RS-485
Protocols Supported Modbus RTU or BACnet MSTP
Address 1 to 247 for Modbus RTU; 0 to 127 for BACnet MS/TP
Baud Rate 9600, 19200, 38400
Parity Modbus RTU: NONE, ODD, EVEN; BACnet MS/TP: NONE (fixed)
Physical Interface RJ45 connector with 10/100 Mbit Ethernet
Protocols Supported Modbus TCP, BACnet IP, SNMP V2c
Removable Connectors 4.4 to 5.3 in-lb (0.5 to 0.6 N-m)
Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
Storage Temperature -40 to 158°F (-40 to 70°C)
Altitude of Operation 9,842.5' (3,000 m)
Mounting Location Indoor use, dry location
Warranty 5 years limited
Agency Approvals IEC/EN61010-1
Installation Category Cat III, pollution degree 2
Click here for complete specifications on the Veris E34E28

What's included with the Veris E34E28

  • Veris E34E28 Multi-Circuit/Multi-Circuit Meter, BACnet MST/TP, 28 x 3-phase meters

Ask a question about Veris E34E28 Multi-Circuit/Multi-Circuit Meter, BACnet MST/TP, 28 x 3-phase meters

Customer Reviews for the Veris E34E28

More Veris Products

Calibration Lab