The multi-circuit solid-core panelboard system is ideally suited for applications where loads are dynamic. With advanced functionality, it monitors voltage, current, power and energy consumption for mains and branches in a panelboard. Two 3-phase mains.
The multi-circuit solid-core panelboard system is ideally suited for applications where loads are dynamic. With advanced functionality, it monitors voltage, current, power and energy consumption for mains and branches in a panelboard. Two 3-phase mains.
The multi-circuit solid-core panelboard system is ideally suited for applications where loads are dynamic. With advanced functionality, it monitors voltage, current, power and energy consumption for mains and branches in a panelboard. Two 3-phase mains.
Features
Applications
Measurement Input Voltage | 90 to 277 VAC, 50/60 Hz |
Control Power Voltage | 100 to 277 VAC, 50/60 Hz |
Power/Energy | IEC 62053-21 Class 1, ANSI C12.1-2008 (1% system accuracy, including branch CTs) |
Voltage | ±0.5% of reading 90 to 277 V line-to-neutral |
Sampling Frequency | 2,560 Hz |
Update Rate | Modbus: 1.8 seconds; BACnet: 7 seconds; SNMP: 20 seconds |
Overload Capability | 22 kAIC |
Physical Interface | 10/100 Mbit Ethernet |
Protocols Supported | Modbus TCP, BACnet IP, SNMP |
Physical Interface | 2-wire RS-485 |
Protocols Supported | Modbus RTU, BACnet MS/TP |
Address | 1 and 2 |
Baud Rate | Selectable: 9600, 19200, 38400 |
Parity | Selectable: NONE, ODD, EVEN |
Communication Format | 8 data-bits, 1 start-bit, 1 stop-bit |
Ribbon Cable Support | 4 each 4' (0.9 m) round ribbon cables ship standard; up to 20' (6 m) available |
Operating Temperature | 32 to 140°F (0 to 60°C) <95% RH non-condensing |
Storage Temperature | -40 to 158°F (-40 to 70°C) |
Measurement Input Voltage | 90 to 277 VAC, 50/60 Hz |
Control Power Voltage | 100 to 277 VAC, 50/60 Hz |
Power/Energy | IEC 62053-21 Class 1, ANSI C12.1-2008 (1% system accuracy, including branch CTs) |
Voltage | ±0.5% of reading 90 to 277 V line-to-neutral |
Sampling Frequency | 2,560 Hz |
Update Rate | Modbus: 1.8 seconds; BACnet: 7 seconds; SNMP: 20 seconds |
Overload Capability | 22 kAIC |
Physical Interface | 10/100 Mbit Ethernet |
Protocols Supported | Modbus TCP, BACnet IP, SNMP |
Physical Interface | 2-wire RS-485 |
Protocols Supported | Modbus RTU, BACnet MS/TP |
Address | 1 and 2 |
Baud Rate | Selectable: 9600, 19200, 38400 |
Parity | Selectable: NONE, ODD, EVEN |
Communication Format | 8 data-bits, 1 start-bit, 1 stop-bit |
Ribbon Cable Support | 4 each 4' (0.9 m) round ribbon cables ship standard; up to 20' (6 m) available |
Operating Temperature | 32 to 140°F (0 to 60°C) <95% RH non-condensing |
Storage Temperature | -40 to 158°F (-40 to 70°C) |