Veris E30E284 Multi-Circuit/Panelboard Monitoring System, advanced monitoring with Ethernet, two 3-phase main

Model: E30E284

Veris E30E284 Multi-Circuit/Panelboard Monitoring System, advanced monitoring with Ethernet, two 3-phase main

Model: E30E284

The multi-circuit solid-core panelboard system is ideally suited for applications where loads are dynamic. With advanced functionality, it monitors voltage, current, power and energy consumption for mains and branches in a panelboard. Two 3-phase mains.

The multi-circuit solid-core panelboard system is ideally suited for applications where loads are dynamic. With advanced functionality, it monitors voltage, current, power and energy consumption for mains and branches in a panelboard. Two 3-phase mains.

Sale Price $8169.56 USD
Regular Price $9128.00 USD
Availability 2 to 3 Weeks
Quantity

Veris E30E284 Offers

The multi-circuit solid-core panelboard system is ideally suited for applications where loads are dynamic. With advanced functionality, it monitors voltage, current, power and energy consumption for mains and branches in a panelboard. Two 3-phase mains.

Features

  • Compact solution for panelboard monitoring
  • ANSI and IEC Class 1 metering system accuracy (1%, including branch CTs)
  • Built-in Ethernet and serial communication with Modbus, BACnet and SNMP protocols
  • Phase angle measurements of every current and voltage input
  • Energy snapshots and demand measurements
  • Signed Power factor to indicate leading or lagging current
  • Reports voltage, current, power and energy for mains and branches; 1 product covers the whole panelboard
  • Monitors up to 92 circuits (84 branch circuits, two 3-phase main, 2 neutral) with 1 device to save space
  • 0.71" (18 mm) spaced solid-core 100 A current sensors support flexible installation
  • 4 user-configurable alarm thresholds and individual monitoring of all branches for improved load management
  • Versatile support for any combination of 1, 2, 3 pole breakers
  • Applications

    • Data Center Energy Management
    • Overload Protection and Infrastructure Management
    • Subtenant Billing
    • Load-Based Cost Allocation
    • Load Management
    • Load Balancing
    • Lighting Circuit Monitoring

    Veris E30E284 Specifications

    Measurement Input Voltage 90 to 277 VAC, 50/60 Hz
    Control Power Voltage 100 to 277 VAC, 50/60 Hz
    Power/Energy IEC 62053-21 Class 1, ANSI C12.1-2008 (1% system accuracy, including branch CTs)
    Voltage ±0.5% of reading 90 to 277 V line-to-neutral
    Sampling Frequency 2,560 Hz
    Update Rate Modbus: 1.8 seconds; BACnet: 7 seconds; SNMP: 20 seconds
    Overload Capability 22 kAIC
    Physical Interface 10/100 Mbit Ethernet
    Protocols Supported Modbus TCP, BACnet IP, SNMP
    Physical Interface 2-wire RS-485
    Protocols Supported Modbus RTU, BACnet MS/TP
    Address 1 and 2
    Baud Rate Selectable: 9600, 19200, 38400
    Parity Selectable: NONE, ODD, EVEN
    Communication Format 8 data-bits, 1 start-bit, 1 stop-bit
    Ribbon Cable Support 4 each 4' (0.9 m) round ribbon cables ship standard; up to 20' (6 m) available
    Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
    Storage Temperature -40 to 158°F (-40 to 70°C)
    Click here for complete specifications on the Veris E30E284

    What's included with the Veris E30E284

    • Advanced Measurement Unit with Metal Housing
    • 4 x Strips of 21 Each 100 A Solid-Core Current Transducers Spaced 0.71" (18 mm) Apart
    • 4 x 4' (121.9 cm) Round Ribbon Cables for Connecting CT strips to Main Board

    Ask a question about Veris E30E284 Multi-Circuit/Panelboard Monitoring System, advanced monitoring with Ethernet, two 3-phase main

    Customer Reviews for the Veris E30E284

    Veris E30E284 Offers

    The multi-circuit solid-core panelboard system is ideally suited for applications where loads are dynamic. With advanced functionality, it monitors voltage, current, power and energy consumption for mains and branches in a panelboard. Two 3-phase mains.

    Features

    • Compact solution for panelboard monitoring
    • ANSI and IEC Class 1 metering system accuracy (1%, including branch CTs)
    • Built-in Ethernet and serial communication with Modbus, BACnet and SNMP protocols
    • Phase angle measurements of every current and voltage input
    • Energy snapshots and demand measurements
    • Signed Power factor to indicate leading or lagging current
    • Reports voltage, current, power and energy for mains and branches; 1 product covers the whole panelboard
    • Monitors up to 92 circuits (84 branch circuits, two 3-phase main, 2 neutral) with 1 device to save space
    • 0.71" (18 mm) spaced solid-core 100 A current sensors support flexible installation
    • 4 user-configurable alarm thresholds and individual monitoring of all branches for improved load management
  • Versatile support for any combination of 1, 2, 3 pole breakers
  • Applications

    • Data Center Energy Management
    • Overload Protection and Infrastructure Management
    • Subtenant Billing
    • Load-Based Cost Allocation
    • Load Management
    • Load Balancing
    • Lighting Circuit Monitoring

    Veris E30E284 Specifications

    Measurement Input Voltage 90 to 277 VAC, 50/60 Hz
    Control Power Voltage 100 to 277 VAC, 50/60 Hz
    Power/Energy IEC 62053-21 Class 1, ANSI C12.1-2008 (1% system accuracy, including branch CTs)
    Voltage ±0.5% of reading 90 to 277 V line-to-neutral
    Sampling Frequency 2,560 Hz
    Update Rate Modbus: 1.8 seconds; BACnet: 7 seconds; SNMP: 20 seconds
    Overload Capability 22 kAIC
    Physical Interface 10/100 Mbit Ethernet
    Protocols Supported Modbus TCP, BACnet IP, SNMP
    Physical Interface 2-wire RS-485
    Protocols Supported Modbus RTU, BACnet MS/TP
    Address 1 and 2
    Baud Rate Selectable: 9600, 19200, 38400
    Parity Selectable: NONE, ODD, EVEN
    Communication Format 8 data-bits, 1 start-bit, 1 stop-bit
    Ribbon Cable Support 4 each 4' (0.9 m) round ribbon cables ship standard; up to 20' (6 m) available
    Operating Temperature 32 to 140°F (0 to 60°C) <95% RH non-condensing
    Storage Temperature -40 to 158°F (-40 to 70°C)
    Click here for complete specifications on the Veris E30E284

    What's included with the Veris E30E284

    • Advanced Measurement Unit with Metal Housing
    • 4 x Strips of 21 Each 100 A Solid-Core Current Transducers Spaced 0.71" (18 mm) Apart
    • 4 x 4' (121.9 cm) Round Ribbon Cables for Connecting CT strips to Main Board

    Ask a question about Veris E30E284 Multi-Circuit/Panelboard Monitoring System, advanced monitoring with Ethernet, two 3-phase main

    Customer Reviews for the Veris E30E284

    More Veris Products

    Calibration Lab