Veris E23C6-18 Single-Circuit Power and Energy Meter with Modbus and BACnet MS/TP protocol output, 18" Rogowski CT

Model: E23C6-18

Veris E23C6-18 Single-Circuit Power and Energy Meter with Modbus and BACnet MS/TP protocol output, 18" Rogowski CT

Model: E23C6-18

Offers a unique solution for measuring energy data, this meter features maximum flexibility for retrofit applications. Provides innovative three-phase networked (Modbus RTU and BACnet MS/TP) power transducers that calibrate measurement electronics, high accuracy 18" industrial-grade CTs, and fusing protection in a single package.

Offers a unique solution for measuring energy data, this meter features maximum flexibility for retrofit applications. Provides innovative three-phase networked (Modbus RTU and BACnet MS/TP) power transducers that calibrate measurement electronics, high accuracy 18" industrial-grade CTs, and fusing protection in a single package.

Sale Price $1345.19 USD
Regular Price $1503.00 USD
Availability 9 to 10 Weeks
Quantity

Veris E23C6-18 Offers

Features

  • Pre-wired and factory calibrated
  • Modbus and BACnet protocols along with uni-directional and bi-directional feature sets in one unit
  • Easy installation: DIN rail or screw mount options (with included mounting bracket)
  • Protocol support: Modbus RTU and BACnet MS/TP

Applications

  • Energy monitoring (BAS)
  • Renewable energy
  • Energy management
  • Commercial sub-metering
  • Industrial monitoring
  • Cost allocation

Veris E23C6-18 Specifications

Measurement Accuracy
Real Power and Energy 1/3 V current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1%
Rogowski current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1%
Reactive Power and Energy IEC 62053-24 Class 1, 1%
System Accuracy 1%
Input Voltage
Measured AC Voltage Minimum 90 VL-N (156 VL-L) for stated accuracy;
UL maximum: 480 VL-L (277 VL-N);
CE maximum: 300 VL-N
Impedance 2.5 MΩL-N/5 MΩL-L
Frequency Range 45 to 65 Hz
Input Current
Measurement Input Range 0 to 0.333 VAC (+20% over-range)
Impedance 33 kΩ
Control Power
AC AC: Drawn from phase A-B line-to-line voltage input;
4 VA maximum: 90 VL-N minimum;
UL maximum: 480 VL-L (277 VL-N);
CE maximum: 300 VL-N
Ride-through Time 50 ms at 120 VAC
General Specifications
Ingress Protection (IEC 60529) IP20
Plug Wire Size (I/O, Communications, CT) 24 to 16 AWG (0.2 to 1.5 mm2)
CT Rating 1000 VAC reinforced insulation rating
Environmental Conditions Operating temperature: 32 to 158°F (0 to 70°C)
Storage temperature: -40 to 158°F (-40 to 70°C)
Humidity range: <95% RH (non-condensing)
Altitude: 1.86 mi (3 km) maximum
Pollution degree: 2
Size 18"
Click here for complete specifications on the Veris E23C6-18

What's included with the Veris E23C6-18

  • Veris E23C6-18 Single-Circuit Power and Energy Meter with Modbus and BACnet MS/TP protocol output, 18" Rogowski CT

Ask a question about Veris E23C6-18 Single-Circuit Power and Energy Meter with Modbus and BACnet MS/TP protocol output, 18" Rogowski CT

Customer Reviews for the Veris E23C6-18

Veris E23C6-18 Offers

Features

  • Pre-wired and factory calibrated
  • Modbus and BACnet protocols along with uni-directional and bi-directional feature sets in one unit
  • Easy installation: DIN rail or screw mount options (with included mounting bracket)
  • Protocol support: Modbus RTU and BACnet MS/TP

Applications

  • Energy monitoring (BAS)
  • Renewable energy
  • Energy management
  • Commercial sub-metering
  • Industrial monitoring
  • Cost allocation

Veris E23C6-18 Specifications

Measurement Accuracy
Real Power and Energy 1/3 V current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1%
Rogowski current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1%
Reactive Power and Energy IEC 62053-24 Class 1, 1%
System Accuracy 1%
Input Voltage
Measured AC Voltage Minimum 90 VL-N (156 VL-L) for stated accuracy;
UL maximum: 480 VL-L (277 VL-N);
CE maximum: 300 VL-N
Impedance 2.5 MΩL-N/5 MΩL-L
Frequency Range 45 to 65 Hz
Input Current
Measurement Input Range 0 to 0.333 VAC (+20% over-range)
Impedance 33 kΩ
Control Power
AC AC: Drawn from phase A-B line-to-line voltage input;
4 VA maximum: 90 VL-N minimum;
UL maximum: 480 VL-L (277 VL-N);
CE maximum: 300 VL-N
Ride-through Time 50 ms at 120 VAC
General Specifications
Ingress Protection (IEC 60529) IP20
Plug Wire Size (I/O, Communications, CT) 24 to 16 AWG (0.2 to 1.5 mm2)
CT Rating 1000 VAC reinforced insulation rating
Environmental Conditions Operating temperature: 32 to 158°F (0 to 70°C)
Storage temperature: -40 to 158°F (-40 to 70°C)
Humidity range: <95% RH (non-condensing)
Altitude: 1.86 mi (3 km) maximum
Pollution degree: 2
Size 18"
Click here for complete specifications on the Veris E23C6-18

What's included with the Veris E23C6-18

  • Veris E23C6-18 Single-Circuit Power and Energy Meter with Modbus and BACnet MS/TP protocol output, 18" Rogowski CT

Ask a question about Veris E23C6-18 Single-Circuit Power and Energy Meter with Modbus and BACnet MS/TP protocol output, 18" Rogowski CT

Customer Reviews for the Veris E23C6-18

More Veris Products

Calibration Lab