Work with full HVAC/R functionality and advanced features like DC amps, LRA inrush, differential temperature, and wireless connection to a free app for logging, graphing, and emailing results with this wireless TRMS clamp meter. In addition, this meter features a three-phase and unbalanced motor test, 600 A AC/DC, and 9999 μF.
Work with full HVAC/R functionality and advanced features like DC amps, LRA inrush, differential temperature, and wireless connection to a free app for logging, graphing, and emailing results with this wireless TRMS clamp meter. In addition, this meter features a three-phase and unbalanced motor test, 600 A AC/DC, and 9999 μF.
Determine a motor's load efficiency, low Z (impedance) to improve accuracy by reducing ghost voltages, and a low pass filter to screen out unwanted higher frequencies from variable frequency drives
Features
Made better
All the pro features you love
Plus, added bonus motor tests
Applications
DC Amps Measurement - Jaw Input* *Minimum current for clamp measurement: 0.2 A |
|
Range | 60 A 600 A |
Resolution | 0.01 A 0.1 A |
Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
Overload Protection | 600 V RMS |
AC Amps Measurement - Jaw Input* *45 to 400 Hz True RMS *Minimum current for clamp measurement: 0.3 A |
|
Range | 60 A 600 A |
Resolution | 0.01 A 0.1 A |
Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
Overload Protection | 600 V RMS |
DC Low Amps Measurement - Test Lead Input | |
Range | 600 uA 2000 u A |
Resolution | 0.1 uA 1 uA |
Accuracy | ±1.2% + 3 digits |
Overload Protection | 600 V RMS |
AC Low Amps Measurement - Test Lead Input* *45 to 400 Hz true RMS |
|
Range | 600 uA 2000 u A |
Resolution | 0.1 uA 1 uA |
Accuracy | ±1.5% + 3 digits |
Overload Protection | 600 V RMS |
DC Volts Measurement | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | ±0.5% + 4 digits ±0.8% + 5 digits |
Overload Protection | 1000 V RMS |
AC Volts Measurement* *45 to 400 Hz true RMS |
|
Range | 600 mV 6 V 60 V 600 V 1000 V |
AC Volts Measurement | |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | ±1% + 3 digits |
Overload Protection | 1000 V RMS |
Ohms Measurement | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 Mω |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | ±0.8% + 3 digits ±1.2% + 3 digits |
Overload Protection | 600 V RMS |
Diode Test | |
Range | 3.1 V |
Open Circuit Voltage | <3.2 V DC |
Test Current (Typical) | 0.25 mA |
Overload Protection | 600 V RMS |
Capacitance Measurement | |
Range | 10 nF 100 nF 1 uF 10 uF 100 uF 9999 uF |
Resolution | 0.01 bF 0.1 nF 0.001 uF 0.01 uF 0.1 uF 1 uF |
Accuracy | 2.5% + 5 digits 3% + 5 digits |
Overload Protection | 600 V RMS |
Temperature Measurement* *Sensor: "K" type thermocouple, sensor accuracy not included |
|
Range | -328 to 999°F -200 to 999°C 1000 to 2462°F 1000 to 1350°C |
Resolution | 0.1°F 0.1°C 1°F 1°C |
Accuracy | ±(1% + 3.6°F) ±(1% + 2°C) ±(1% + 3°F) ±(1% + 2°C) |
Overload Protection | 30 V RMS |
Frequency Measurement - Test Lead Input* *Sensitivity: 1.8 Vrms |
|
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | 0.1% + 3 digits |
Overload Protection | 1000 V RMS |
Frequency Measurement - Jaw Input | |
Range | 999.9 Hz 1999 Hz |
Resolution | 0.1 Hz 1 Hz |
Accuracy | 0.5% + 5 digits |
Overload Protection | 600 V RMS |
Duty(%) Cycle Measurement | |
Range | 1 to 99% |
Accuracy | ±(0.2% per kHz + 0.1% + 5 digits) |
Overload Protection | 1000 V RMS |
Audible Continuity Measurement | |
Open Circuit Voltage <1 | Threshold Approximate: <40 Ω |
Overload Protection | 600 V RMS |
General Specifications | |
Display | 3 ⅚ digits 6000 count |
Back Light | Yes |
Refresh Rate | 3/second |
Over Range | "OL" is displayed |
Apo | Auto power off after 30 minutes of use |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) |
Operating Humidity | <80% |
Test Leads | Test leads with alligator clips and back probes Use ATL58 test leads with ABP3 back probes and AAC3 alligator clips ATL55, ATL57 and ATLTX will not work with DL599 |
Battery Type | 4 x AAA |
Pollution Degree | 2 |
CAT Rating | CATIV 600 V |
RoHS | Yes |
FCC/IC Compliant | FCC |
Certifications | cETLus UL 61010-1: 2012, IP42, 6' drop protection |
Dimensions | 9.45 x 2.58 x 1.67" (240.03 x 65.52 x 42.42 mm) |
Weight | 0.926 lbs (0.42 kg) |
Click on a category to view a selection of compatible accessories with the UEi DL599 Wireless TRMS Clamp Meter with three-phase and unbalance motor tests, 600 A AC/DC, 9999 μF.
DC Amps Measurement - Jaw Input* *Minimum current for clamp measurement: 0.2 A |
|
Range | 60 A 600 A |
Resolution | 0.01 A 0.1 A |
Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
Overload Protection | 600 V RMS |
AC Amps Measurement - Jaw Input* *45 to 400 Hz True RMS *Minimum current for clamp measurement: 0.3 A |
|
Range | 60 A 600 A |
Resolution | 0.01 A 0.1 A |
Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
Overload Protection | 600 V RMS |
DC Low Amps Measurement - Test Lead Input | |
Range | 600 uA 2000 u A |
Resolution | 0.1 uA 1 uA |
Accuracy | ±1.2% + 3 digits |
Overload Protection | 600 V RMS |
AC Low Amps Measurement - Test Lead Input* *45 to 400 Hz true RMS |
|
Range | 600 uA 2000 u A |
Resolution | 0.1 uA 1 uA |
Accuracy | ±1.5% + 3 digits |
Overload Protection | 600 V RMS |
DC Volts Measurement | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | ±0.5% + 4 digits ±0.8% + 5 digits |
Overload Protection | 1000 V RMS |
AC Volts Measurement* *45 to 400 Hz true RMS |
|
Range | 600 mV 6 V 60 V 600 V 1000 V |
AC Volts Measurement | |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | ±1% + 3 digits |
Overload Protection | 1000 V RMS |
Ohms Measurement | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 Mω |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | ±0.8% + 3 digits ±1.2% + 3 digits |
Overload Protection | 600 V RMS |
Diode Test | |
Range | 3.1 V |
Open Circuit Voltage | <3.2 V DC |
Test Current (Typical) | 0.25 mA |
Overload Protection | 600 V RMS |
Capacitance Measurement | |
Range | 10 nF 100 nF 1 uF 10 uF 100 uF 9999 uF |
Resolution | 0.01 bF 0.1 nF 0.001 uF 0.01 uF 0.1 uF 1 uF |
Accuracy | 2.5% + 5 digits 3% + 5 digits |
Overload Protection | 600 V RMS |
Temperature Measurement* *Sensor: "K" type thermocouple, sensor accuracy not included |
|
Range | -328 to 999°F -200 to 999°C 1000 to 2462°F 1000 to 1350°C |
Resolution | 0.1°F 0.1°C 1°F 1°C |
Accuracy | ±(1% + 3.6°F) ±(1% + 2°C) ±(1% + 3°F) ±(1% + 2°C) |
Overload Protection | 30 V RMS |
Frequency Measurement - Test Lead Input* *Sensitivity: 1.8 Vrms |
|
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | 0.1% + 3 digits |
Overload Protection | 1000 V RMS |
Frequency Measurement - Jaw Input | |
Range | 999.9 Hz 1999 Hz |
Resolution | 0.1 Hz 1 Hz |
Accuracy | 0.5% + 5 digits |
Overload Protection | 600 V RMS |
Duty(%) Cycle Measurement | |
Range | 1 to 99% |
Accuracy | ±(0.2% per kHz + 0.1% + 5 digits) |
Overload Protection | 1000 V RMS |
Audible Continuity Measurement | |
Open Circuit Voltage <1 | Threshold Approximate: <40 Ω |
Overload Protection | 600 V RMS |
General Specifications | |
Display | 3 ⅚ digits 6000 count |
Back Light | Yes |
Refresh Rate | 3/second |
Over Range | "OL" is displayed |
Apo | Auto power off after 30 minutes of use |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) |
Operating Humidity | <80% |
Test Leads | Test leads with alligator clips and back probes Use ATL58 test leads with ABP3 back probes and AAC3 alligator clips ATL55, ATL57 and ATLTX will not work with DL599 |
Battery Type | 4 x AAA |
Pollution Degree | 2 |
CAT Rating | CATIV 600 V |
RoHS | Yes |
FCC/IC Compliant | FCC |
Certifications | cETLus UL 61010-1: 2012, IP42, 6' drop protection |
Dimensions | 9.45 x 2.58 x 1.67" (240.03 x 65.52 x 42.42 mm) |
Weight | 0.926 lbs (0.42 kg) |
Click on a category to view a selection of compatible accessories with the UEi DL599 Wireless TRMS Clamp Meter with three-phase and unbalance motor tests, 600 A AC/DC, 9999 μF.