Eliminate the hassle and downtime of replacing the O2 sensor with this combustion analyzer that features EOS technology, a 30-second start-up time, and a NOx Filtered CO Sensor. Complete with a flue probe, two K-type probes, particle filter, tubing, and a carrying case, the gas analyzer kit offers versatility and reliable test results.
Eliminate the hassle and downtime of replacing the O2 sensor with this combustion analyzer that features EOS technology, a 30-second start-up time, and a NOx Filtered CO Sensor. Complete with a flue probe, two K-type probes, particle filter, tubing, and a carrying case, the gas analyzer kit offers versatility and reliable test results.
With a 30 second start-up time, the combustion analyzer offers direct CO2 measurements using an EOS technology sensor. With a protective rubber boot for hands-free operation, the unit includes a probe with an integral temperature sensor.
Measures CO, CO2, NO, Pressure, Flue, and Inlet Temperature and calculates O2, differential temperature, efficiency, excess air, losses, CO/CO2 ratio, and differential pressure, the analyzer also features a large 6 line display.
Features
Applications
Temperature Measurement | |
Flue Temperature | Range: 32 to 1112˚F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±0.5°F (0.5°C) |
Inlet Temperature (Internal Sensor) | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±1˚F (1°C) |
Inlet Temperature (External Sensor) | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±0.5°F (0.5°C) |
Flue Gas Measurement | |
Carbon Monoxide | Range: 0 to 2000 ppm Resolution: 1 ppm Accuracy: ±3 ppm or ±5% reading (whichever is greater) |
Carbon Dioxide | Range: 0 to 20% Resolution: 0.1% Accuracy: ±0.3% volume |
Calculations | |
Oxygen | Range: 0 to 21% Resolution: 0.1% Accuracy: ±0.3% volume |
Efficiency (Net or Gross) | Range: 0 to 99.9% Resolution: 0.1% Accuracy: ±1% reading |
Efficiency High (C) | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±1% reading |
Excess Air | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±0.2% reading |
CO/CO2 Ratio | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±0.2% reading |
Preprogrammed Fuels | Pellets, light oil, LPG, butane, propane, natural gas, bio oil, heavy oil |
Operating Conditions | |
Temperature | 32 to 113°F (0 to 45°C) |
Humidity | 15 to 90% R.H. |
Power Supply | Rechargeable batteries, USB charging |
Dimensions | 8.54 x 4.18 x 1.86" |
Weight | 1 lb (453 g) |
Click on a category to view a selection of compatible accessories with the UEi C164 Combustion Analyzer with nitric oxide sensor.
Temperature Measurement | |
Flue Temperature | Range: 32 to 1112˚F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±0.5°F (0.5°C) |
Inlet Temperature (Internal Sensor) | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±1˚F (1°C) |
Inlet Temperature (External Sensor) | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±0.5°F (0.5°C) |
Flue Gas Measurement | |
Carbon Monoxide | Range: 0 to 2000 ppm Resolution: 1 ppm Accuracy: ±3 ppm or ±5% reading (whichever is greater) |
Carbon Dioxide | Range: 0 to 20% Resolution: 0.1% Accuracy: ±0.3% volume |
Calculations | |
Oxygen | Range: 0 to 21% Resolution: 0.1% Accuracy: ±0.3% volume |
Efficiency (Net or Gross) | Range: 0 to 99.9% Resolution: 0.1% Accuracy: ±1% reading |
Efficiency High (C) | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±1% reading |
Excess Air | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±0.2% reading |
CO/CO2 Ratio | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±0.2% reading |
Preprogrammed Fuels | Pellets, light oil, LPG, butane, propane, natural gas, bio oil, heavy oil |
Operating Conditions | |
Temperature | 32 to 113°F (0 to 45°C) |
Humidity | 15 to 90% R.H. |
Power Supply | Rechargeable batteries, USB charging |
Dimensions | 8.54 x 4.18 x 1.86" |
Weight | 1 lb (453 g) |
Click on a category to view a selection of compatible accessories with the UEi C164 Combustion Analyzer with nitric oxide sensor.