TSI/Alnor PAN231-110 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 110 to 120 V

Model: PAN231-110

TSI/Alnor PAN231-110 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 110 to 120 V

Model: PAN231-110

Use this PANDA system to test air ducts for leaks. The system features a high-flow fan and comes with an air velocity meter and micromanometer.

Use this PANDA system to test air ducts for leaks. The system features a high-flow fan and comes with an air velocity meter and micromanometer.

Sale Price $9792.00 USD
Regular Price $10880.00 USD
Availability Currently Not Available
Quantity

TSI/Alnor PAN231-110 Offers



With this TSI/Alnor PAN231-110 Positive and Negative Duct Accreditation (PANDA) System, you can easily test ductwork for leakage. By finding and fixing duct leaks, you'll help save energy in your buildings. The high-flow fan is capable of handling large sections of ductwork, while the VelociCalc meter lets you measure temperature, barometric pressure and volume flow.

Features

  • Perform positive and negative duct leakage testing in 1 complete system
  • Makes it easy to locate and fix duct leaks
  • Includes TSI/Alnor 9565-P VelociCalc ventilation meter and 5815 DP-Calc micromanometer to capture measurements
  • Use the 9565-P ventilation meter to calculate volume flow, temperature and barometric pressure measurements
  • 5815 micromanometer is capable of capturing pressure measurements
  • Features a high-flow fan to test large sections of ductwork
  • Unit fits comfortably in the back of vans and trucks
  • Delivers pass/fail reporting standards for SMACNA HVAC/R Air Duct Leakage Test Manual, EN12237 Ventilation for Buildings, EN1507 Ventilation for Buildings and EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution System

TSI/Alnor PAN231-110 Specifications


Pressure Measurement5815: ±15" W.G. (±3,735 Pa), 9565-P: 20.36 to 36.648 inHg (690 to 1,241 hPa) barometric
Volume Flow MeasurementHigh leakage range: 21 to 424 cfm (10 to 200 L/s), 36 to 720 m³/hr, low leakage range: 2 to 27.5 cfm (1 to 13 L/s), 3.6 to 46.9 m³/hr
Temperature Measurement-40 to 1,200°F (-40 to 650°C)
Actual Duct Static Range±10" W.G. (±2,500 Pa) at zero flow
AccuracyPressure Management: 1% of reading ±0.005" W.G. (±1 Pa), Volume Flow Measurement: ±2.5% of reading or ±0.02 cfm (±0.01 L/s, ±0.04m³/hr), whichever is greater, Temperature Measurement: ±0.1% of reading ±2°F (±0.056% of reading ±1.1°C), Barometric Pressure Measurement: ±2% of reading
Power Supply110 to 120 V, 1 phase, 50/60 Hz, 16 A
Product Length44.5" (1,130 mm)
Product Width26" (660 mm)
Product Height20" (510 mm)
Product Weight121 lbs (55 kg)
Click here for complete specifications on the TSI/Alnor PAN231-110

What's included with the TSI/Alnor PAN231-110


  • 9565-P VelociCalc Meter
  • 5815 DP-Calc Micromanometer

Ask a question about TSI/Alnor PAN231-110 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 110 to 120 V

Customer Reviews for the TSI/Alnor PAN231-110

TSI/Alnor PAN231-110 Offers



With this TSI/Alnor PAN231-110 Positive and Negative Duct Accreditation (PANDA) System, you can easily test ductwork for leakage. By finding and fixing duct leaks, you'll help save energy in your buildings. The high-flow fan is capable of handling large sections of ductwork, while the VelociCalc meter lets you measure temperature, barometric pressure and volume flow.

Features

  • Perform positive and negative duct leakage testing in 1 complete system
  • Makes it easy to locate and fix duct leaks
  • Includes TSI/Alnor 9565-P VelociCalc ventilation meter and 5815 DP-Calc micromanometer to capture measurements
  • Use the 9565-P ventilation meter to calculate volume flow, temperature and barometric pressure measurements
  • 5815 micromanometer is capable of capturing pressure measurements
  • Features a high-flow fan to test large sections of ductwork
  • Unit fits comfortably in the back of vans and trucks
  • Delivers pass/fail reporting standards for SMACNA HVAC/R Air Duct Leakage Test Manual, EN12237 Ventilation for Buildings, EN1507 Ventilation for Buildings and EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution System

TSI/Alnor PAN231-110 Specifications


Pressure Measurement5815: ±15" W.G. (±3,735 Pa), 9565-P: 20.36 to 36.648 inHg (690 to 1,241 hPa) barometric
Volume Flow MeasurementHigh leakage range: 21 to 424 cfm (10 to 200 L/s), 36 to 720 m³/hr, low leakage range: 2 to 27.5 cfm (1 to 13 L/s), 3.6 to 46.9 m³/hr
Temperature Measurement-40 to 1,200°F (-40 to 650°C)
Actual Duct Static Range±10" W.G. (±2,500 Pa) at zero flow
AccuracyPressure Management: 1% of reading ±0.005" W.G. (±1 Pa), Volume Flow Measurement: ±2.5% of reading or ±0.02 cfm (±0.01 L/s, ±0.04m³/hr), whichever is greater, Temperature Measurement: ±0.1% of reading ±2°F (±0.056% of reading ±1.1°C), Barometric Pressure Measurement: ±2% of reading
Power Supply110 to 120 V, 1 phase, 50/60 Hz, 16 A
Product Length44.5" (1,130 mm)
Product Width26" (660 mm)
Product Height20" (510 mm)
Product Weight121 lbs (55 kg)
Click here for complete specifications on the TSI/Alnor PAN231-110

What's included with the TSI/Alnor PAN231-110


  • 9565-P VelociCalc Meter
  • 5815 DP-Calc Micromanometer

Ask a question about TSI/Alnor PAN231-110 Positive and Negative Duct Accreditation (PANDA) System, 21 to 424 cfm, 110 to 120 V