TSI/Alnor 5825-AC DP-Calc High-Performance Micromanometer with ISO 17025 accreditation

Model: 5825-AC

TSI/Alnor 5825-AC DP-Calc High-Performance Micromanometer with ISO 17025 accreditation

Model: 5825-AC

Used with pitot tubes (sold separately) to measure quickly and accurately measure differential and static pressure and duct velocity, this high-performance handheld micromanometer is easy to operate. In addition, it can calculate flow, has data logging capabilities, and comes with an ISO accreditation for differential pressure.

Used with pitot tubes (sold separately) to measure quickly and accurately measure differential and static pressure and duct velocity, this high-performance handheld micromanometer is easy to operate. In addition, it can calculate flow, has data logging capabilities, and comes with an ISO accreditation for differential pressure.

Sale Price $1013.00 USD
Regular Price $1125.00 USD
Availability 3 to 4 Weeks
Quantity

TSI/Alnor 5825-AC Offers

Features

  • Measure differential and static pressure from -15 to 15 "H2O (-3735 to 3735 Pa)
  • Calculate and display velocity when using a pitot tube (sold separately)
  • Calculates flow
  • Variable time constant
  • Statistics
  • Data logging with time and date stamp
  • Stores 12,700 samples and 100 test IDs
  • Includes LogDat2™ software and downloading software
  • Programmable K factors

Applications

  • HVAC/R commissioning an troubleshooting
  • Testing and balancing
  • Pitot tube duct traverses
  • Static pressure measurement
  • Pressure drop across filters, coils, fans, and diffusers
  • Environmental air flow testing

TSI/Alnor 5825-AC Specifications

Static/Differential Pressure Range: -15 to 15 "H2O (-28 to 28 mm Hg, -3735 to 3735 Pa)
Accuracy: ±1% of reading ±0.0005 "H2O (±0.01 mm Hg, ±1 Pa)
Resolution: 0.001 "H2O (0.1 Pa, 0.01 mmHg)
Velocity (Pitot Tube Required) Range2: 250 to 15,500 ft/min (1.27 to 78.7 m/s)
Accuracy3: ±1.5% at 2000 ft/min (10.16 m/s)
Resolution: 1 ft/min (0.1 m/s)
Duct Size 1 to 500" in increments of 0.1" (2.5 to 1270 cm in increments of 0.1 cm)
Volumetric Flow Rate Actual rate is a function of velocity, pressure, duct size, and K factor
Data Storage 12,700 samples and 100 test IDs
Logging Interval 1 second to 1 hour
Time Constant User selectable
Environmental Conditions Operating temperature: 40 to 113°F (5 to 45°C)
Storage temperature: -4 to 140°F (-20 to 60°C)
Power Requirements 4 x AA batteries or optional AC adapter (sold separately)
Dimensions 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm)
Weight 0.6 lbs (0.27 kg)
Click here for complete specifications on the TSI/Alnor 5825-AC

What's included with the TSI/Alnor 5825-AC

  • High Performance Micromanometer
  • 2 x Calibration Certificate
  • 47" (1.2 m) Rubber Rubes
  • Static Pressure Tip
  • Hard Carrying Case
  • 4 x Alkaline Batteries
  • Operation and Service Manual
  • ISO 17025 Accreditation
  • LogDat2™ Downloading Software and USB Cable

Click on a category to view a selection of compatible accessories with the TSI/Alnor 5825-AC DP-Calc High-Performance Micromanometer with ISO 17025 accreditation.

TSI 634634004 Telescoping Pitot Probe, 8" to 38" 634634004
For use with the AP800 AirPro® Micromanometer.




TSI 634634005 Pitot Probe, 8 mm Diameter, 60" 634634005
For use with the AP800 AirPro® Micromanometer.




TSI 634634003 Pitot Probe, 8 mm Diameter, 36" 634634003
For use with the AP800 AirPro® Micromanometer.




TSI 634634002 Pitot Probe, 8 mm Diameter, 24" 634634002
For use with the AP800 AirPro® Micromanometer.




TSI 634634001 Pitot Probe, 8 mm Diameter, 18" 634634001
For use with the AP800 AirPro® Micromanometer.




TSI 634634000 Pitot Probe, 8 mm Diameter, 12" 634634000
For use with the AP800 AirPro® Micromanometer.




TSI Alnor 372000000 Norprene Tubing, 8', 0.19" diameter 372000000
The tubing is crafted from durable norprene material. It has a diameter of 0.19" (0.48 cm).




Ask a question about TSI/Alnor 5825-AC DP-Calc High-Performance Micromanometer with ISO 17025 accreditation

Customer Reviews for the TSI/Alnor 5825-AC

TSI/Alnor 5825-AC Offers

Features

  • Measure differential and static pressure from -15 to 15 "H2O (-3735 to 3735 Pa)
  • Calculate and display velocity when using a pitot tube (sold separately)
  • Calculates flow
  • Variable time constant
  • Statistics
  • Data logging with time and date stamp
  • Stores 12,700 samples and 100 test IDs
  • Includes LogDat2™ software and downloading software
  • Programmable K factors

Applications

  • HVAC/R commissioning an troubleshooting
  • Testing and balancing
  • Pitot tube duct traverses
  • Static pressure measurement
  • Pressure drop across filters, coils, fans, and diffusers
  • Environmental air flow testing

TSI/Alnor 5825-AC Specifications

Static/Differential Pressure Range: -15 to 15 "H2O (-28 to 28 mm Hg, -3735 to 3735 Pa)
Accuracy: ±1% of reading ±0.0005 "H2O (±0.01 mm Hg, ±1 Pa)
Resolution: 0.001 "H2O (0.1 Pa, 0.01 mmHg)
Velocity (Pitot Tube Required) Range2: 250 to 15,500 ft/min (1.27 to 78.7 m/s)
Accuracy3: ±1.5% at 2000 ft/min (10.16 m/s)
Resolution: 1 ft/min (0.1 m/s)
Duct Size 1 to 500" in increments of 0.1" (2.5 to 1270 cm in increments of 0.1 cm)
Volumetric Flow Rate Actual rate is a function of velocity, pressure, duct size, and K factor
Data Storage 12,700 samples and 100 test IDs
Logging Interval 1 second to 1 hour
Time Constant User selectable
Environmental Conditions Operating temperature: 40 to 113°F (5 to 45°C)
Storage temperature: -4 to 140°F (-20 to 60°C)
Power Requirements 4 x AA batteries or optional AC adapter (sold separately)
Dimensions 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm)
Weight 0.6 lbs (0.27 kg)
Click here for complete specifications on the TSI/Alnor 5825-AC

What's included with the TSI/Alnor 5825-AC

  • High Performance Micromanometer
  • 2 x Calibration Certificate
  • 47" (1.2 m) Rubber Rubes
  • Static Pressure Tip
  • Hard Carrying Case
  • 4 x Alkaline Batteries
  • Operation and Service Manual
  • ISO 17025 Accreditation
  • LogDat2™ Downloading Software and USB Cable

Click on a category to view a selection of compatible accessories with the TSI/Alnor 5825-AC DP-Calc High-Performance Micromanometer with ISO 17025 accreditation.

TSI 634634004 Telescoping Pitot Probe, 8" to 38" 634634004
For use with the AP800 AirPro® Micromanometer.




TSI 634634005 Pitot Probe, 8 mm Diameter, 60" 634634005
For use with the AP800 AirPro® Micromanometer.




TSI 634634003 Pitot Probe, 8 mm Diameter, 36" 634634003
For use with the AP800 AirPro® Micromanometer.




TSI 634634002 Pitot Probe, 8 mm Diameter, 24" 634634002
For use with the AP800 AirPro® Micromanometer.




TSI 634634001 Pitot Probe, 8 mm Diameter, 18" 634634001
For use with the AP800 AirPro® Micromanometer.




TSI 634634000 Pitot Probe, 8 mm Diameter, 12" 634634000
For use with the AP800 AirPro® Micromanometer.




TSI Alnor 372000000 Norprene Tubing, 8', 0.19" diameter 372000000