TSI 4080-S Certifier Plus Flow Analyzer Test System, Standard Kit

Model: 4080-S

TSI 4080-S Certifier Plus Flow Analyzer Test System, Standard Kit

Model: 4080-S

Measure 28 different test parameters and graph data in real-time with this certifier plus test system standard kit. This kit comes with an inlet filter, an airway pressure fitting, 3 x adapters, a flow module cable, a USB computer cable, a protective cover, a power supply with plug set, and a carrying case.

Measure 28 different test parameters and graph data in real-time with this certifier plus test system standard kit. This kit comes with an inlet filter, an airway pressure fitting, 3 x adapters, a flow module cable, a USB computer cable, a protective cover, a power supply with plug set, and a carrying case.

Sale Price $5153.00 USD
Regular Price $5725.00 USD
Availability 1 to 2 Weeks
Quantity

TSI/Alnor 4080-S Offers

Test a variety of medical equipment such as anesthesia gas delivery machines, air oxygen blenders, medical insufflators, oxygen concentrators, CPAPs, and more with this test system standard kit. In addition, it is a handheld, full-featured system capable of testing virtually all models of ventilators: adult, pediatric, anesthesia, neonatal and high-frequency.

Features

  • Large, high resolution color display and real-time graphing for easy data viewing
  • Simple to use with touchscreen operation and automatic breath triggering
  • Create user configurations to enable faster test setups
  • Li-ion rechargeable batteries provide up to eight hours of continuous operation
  • Data storage using SD Flash card and internal memory
  • Reporting made easier with screen captures, data acquisition, and easy USB export
  • Multiple mounting options saves benchtop space and optimizes your test setups
  • Dual flow module capability for flow module self-checks and simultaneous high and low flow operation

Test parameters

  • Flow rate, peak flow, and minimum flow
  • Inhaled and exhaled tidal volumes, minute volume
  • Low pressure (Differential)
  • Peak, PEEP, and minimum pressures
  • Mean airway pressure
  • High pressure, barometric pressure, plateau pressure
  • Static compliance
  • Static compliance
  • Inspiratory and expiratory times
  • Inspiratory pause time, inspiratory rise time
  • I:E ratio, I:E ratio including pause time
  • Respiratory rate
  • Gas temperature
  • Applications

    • Technicians, engineers, designers, researchers, and scientists
    • Maintenance and field service
    • Engineering product development
    • Manufacturing and quality assurance
    • Research
    • Medical equipment testing (mechanical ventilators, anesthesia machines, air oxygen blenders, insufflators, oxygen concentrators, positive air pressure devices)

    TSI/Alnor 4080-S Specifications

    Gas Calibrations Air, O2, Air/O2 mixtures, N2, CO2, N2O
    Flow Direction Bi-directional (4081 high flow module)
    Gas Conditions STP, ATP, BTPS, BTPD, plus user-defined
    Maximum Breath Rate 1500 BPM
    Pressure Measurements Low, high, barometric
    Dual Flow Module Capability Yes
    Display 5" (127 mm) color touchscreen display up to 18 test parameters
    User Configurations Save, load, and transfer test setups
    Flow Rate – High Flow Air, O2:
    Range: -200 to 300 slpm
    Accuracy: ±2% or 0.075 slpm

    Air/O2: Mixtures:
    Range: 0 to 300 slpm
    Accuracy: ±3% or 0.1 slpm

    N2:
    Range: -200 to 300 slpm
    Accuracy: ±3% or 0.1 slpm

    CO2:
    Range: -40 to 40 slpm
    Accuracy: ±3% or 0.1 slpm
    Flow Rate – Low Flow Air, O2:
    Range: 0.01 to 20 slpm
    Accuracy: ±2% or 0.008 slpm

    N2, CO2:
    Range: 0.01 to 20 slpm
    Accuracy: ±3% or 0.010 slpm

    N2O:
    Range: 0.01 to 20 slpm
    Accuracy: ±4% and 0.025 slpm
    Inhaled Volume – High Flow Air, O2:
    Range: 0.01 to 10 std liters
    Accuracy: ±2% and 0.02 liters

    Air/O2 mixtures:
    Range: 0.01 to 10 std liters
    Accuracy: ±4% and 0.02 liters
    Inhaled Volume – Low Flow Air, O2:
    Range: 1 to 100 std mL
    Accuracy: ±2% or 2 mL

    N2O:
    Range: 1 to 100 std mL
    Accuracy: ±4% or 2 mL
    Exhaled Volume – High Flow Air, O2:
    Range: 0.01 to 10 std liters
    Accuracy: ±3 abd 0.03 liters

    Air/O2 mixtures: 0.01 to 10 std liters
    Accuracy: ±4% and 0.04 liters
    Minute Volume Range: 0.01 to 100 std liters
    Accuracy: ±3%
    Pressure Low:
    Range: -25 to 150 cm H2O
    ±0.5% or 0.15 cm H2O

    High:
    Range: -10 to 150 psi
    Accuracy: ±1% or 0.1 psi

    Barometric:
    Range: 7 to 23 psi
    Accuracy: ±0.16% psi (11 mbar)
    I:E Ratio Range: 1:100 to 100:1
    Accuracy: ±4%
    Respiratory Times:
    Range: 0.04 to 30 seconds
    Accuracy: ±2% or 0.01 seconds

    Rate:
    Range: 1 to 1500 bpm
    Accuracy: ±2% or 0.01 bpm
    Oxygen Concentration Range: 21 to 100%
    Accuracy: ±2%
    AC Adapter Yes
    Data Acquisition Save measurement data and screen captures to internal memory
    USB export
    Computer Interface USB from the 4089 interface module
    Temperature Gas/mode: T
    Range: 41 to 104°F (5 to 40°C)
    Accuracy: 33.8°F (±1°C) at flow rates above 2 L/minute
    Batteries Li-Ion rechargeable 8 hours of continuous operation
    Static Compliance Range: 0.01 to 1000 mBar/mL
    Accuracy: ±3% or 1 mbar/mL
    Click here for complete specifications on the TSI/Alnor 4080-S

    What's included with the TSI/Alnor 4080-S

    • High Flow Module
    • Interface Module
    • Inlet Filter
    • Airway Pressure Fitting
    • 3 x Adapters
    • Silicone Tubing
    • Velcro Strap for High Flow Module
    • Flow Module Cable
    • USB Computer Cable
    • Protective Cover
    • Power Supply with Plug Set
    • Carrying Case
    • Rechargeable Li-Ion Battery (Installed)

    Ask a question about TSI 4080-S Certifier Plus Flow Analyzer Test System, Standard Kit

    Customer Reviews for the TSI/Alnor 4080-S

    TSI/Alnor 4080-S Offers

    Test a variety of medical equipment such as anesthesia gas delivery machines, air oxygen blenders, medical insufflators, oxygen concentrators, CPAPs, and more with this test system standard kit. In addition, it is a handheld, full-featured system capable of testing virtually all models of ventilators: adult, pediatric, anesthesia, neonatal and high-frequency.

    Features

    • Large, high resolution color display and real-time graphing for easy data viewing
    • Simple to use with touchscreen operation and automatic breath triggering
    • Create user configurations to enable faster test setups
    • Li-ion rechargeable batteries provide up to eight hours of continuous operation
    • Data storage using SD Flash card and internal memory
    • Reporting made easier with screen captures, data acquisition, and easy USB export
    • Multiple mounting options saves benchtop space and optimizes your test setups
    • Dual flow module capability for flow module self-checks and simultaneous high and low flow operation

    Test parameters

  • Flow rate, peak flow, and minimum flow
  • Inhaled and exhaled tidal volumes, minute volume
  • Low pressure (Differential)
  • Peak, PEEP, and minimum pressures
  • Mean airway pressure
  • High pressure, barometric pressure, plateau pressure
  • Static compliance
  • Static compliance
  • Inspiratory and expiratory times
  • Inspiratory pause time, inspiratory rise time
  • I:E ratio, I:E ratio including pause time
  • Respiratory rate
  • Gas temperature
  • Applications

    • Technicians, engineers, designers, researchers, and scientists
    • Maintenance and field service
    • Engineering product development
    • Manufacturing and quality assurance
    • Research
    • Medical equipment testing (mechanical ventilators, anesthesia machines, air oxygen blenders, insufflators, oxygen concentrators, positive air pressure devices)

    TSI/Alnor 4080-S Specifications

    Gas Calibrations Air, O2, Air/O2 mixtures, N2, CO2, N2O
    Flow Direction Bi-directional (4081 high flow module)
    Gas Conditions STP, ATP, BTPS, BTPD, plus user-defined
    Maximum Breath Rate 1500 BPM
    Pressure Measurements Low, high, barometric
    Dual Flow Module Capability Yes
    Display 5" (127 mm) color touchscreen display up to 18 test parameters
    User Configurations Save, load, and transfer test setups
    Flow Rate – High Flow Air, O2:
    Range: -200 to 300 slpm
    Accuracy: ±2% or 0.075 slpm

    Air/O2: Mixtures:
    Range: 0 to 300 slpm
    Accuracy: ±3% or 0.1 slpm

    N2:
    Range: -200 to 300 slpm
    Accuracy: ±3% or 0.1 slpm

    CO2:
    Range: -40 to 40 slpm
    Accuracy: ±3% or 0.1 slpm
    Flow Rate – Low Flow Air, O2:
    Range: 0.01 to 20 slpm
    Accuracy: ±2% or 0.008 slpm

    N2, CO2:
    Range: 0.01 to 20 slpm
    Accuracy: ±3% or 0.010 slpm

    N2O:
    Range: 0.01 to 20 slpm
    Accuracy: ±4% and 0.025 slpm
    Inhaled Volume – High Flow Air, O2:
    Range: 0.01 to 10 std liters
    Accuracy: ±2% and 0.02 liters

    Air/O2 mixtures:
    Range: 0.01 to 10 std liters
    Accuracy: ±4% and 0.02 liters
    Inhaled Volume – Low Flow Air, O2:
    Range: 1 to 100 std mL
    Accuracy: ±2% or 2 mL

    N2O:
    Range: 1 to 100 std mL
    Accuracy: ±4% or 2 mL
    Exhaled Volume – High Flow Air, O2:
    Range: 0.01 to 10 std liters
    Accuracy: ±3 abd 0.03 liters

    Air/O2 mixtures: 0.01 to 10 std liters
    Accuracy: ±4% and 0.04 liters
    Minute Volume Range: 0.01 to 100 std liters
    Accuracy: ±3%
    Pressure Low:
    Range: -25 to 150 cm H2O
    ±0.5% or 0.15 cm H2O

    High:
    Range: -10 to 150 psi
    Accuracy: ±1% or 0.1 psi

    Barometric:
    Range: 7 to 23 psi
    Accuracy: ±0.16% psi (11 mbar)
    I:E Ratio Range: 1:100 to 100:1
    Accuracy: ±4%
    Respiratory Times:
    Range: 0.04 to 30 seconds
    Accuracy: ±2% or 0.01 seconds

    Rate:
    Range: 1 to 1500 bpm
    Accuracy: ±2% or 0.01 bpm
    Oxygen Concentration Range: 21 to 100%
    Accuracy: ±2%
    AC Adapter Yes
    Data Acquisition Save measurement data and screen captures to internal memory
    USB export
    Computer Interface USB from the 4089 interface module
    Temperature Gas/mode: T
    Range: 41 to 104°F (5 to 40°C)
    Accuracy: 33.8°F (±1°C) at flow rates above 2 L/minute
    Batteries Li-Ion rechargeable 8 hours of continuous operation
    Static Compliance Range: 0.01 to 1000 mBar/mL
    Accuracy: ±3% or 1 mbar/mL
    Click here for complete specifications on the TSI/Alnor 4080-S

    What's included with the TSI/Alnor 4080-S

    • High Flow Module
    • Interface Module
    • Inlet Filter
    • Airway Pressure Fitting
    • 3 x Adapters
    • Silicone Tubing
    • Velcro Strap for High Flow Module
    • Flow Module Cable
    • USB Computer Cable
    • Protective Cover
    • Power Supply with Plug Set
    • Carrying Case
    • Rechargeable Li-Ion Battery (Installed)

    Ask a question about TSI 4080-S Certifier Plus Flow Analyzer Test System, Standard Kit

    Customer Reviews for the TSI/Alnor 4080-S

    More TSI/Alnor Products

    Calibration Lab