This water tester measures both pH and ORP. It has protective IP67-rated housing to guard against water and dust.
This water tester measures both pH and ORP. It has protective IP67-rated housing to guard against water and dust.
The Traceable 4277 pH/ORP Meter makes it easy to monitor water quality. It tests for both pH and ORP using convenient single-handed operation. It's also durably constructed and can store up to 25 data points at a time, so that you can look back and review the water content as you go. NIST-traceable calibration.
Features
pH Range | 0.00 to 14.00 pH units |
pH Resolution | 0.01 pH units |
pH Accuracy | ±0.02 pH units |
ORP Range | -1800 to 1800 mV |
ORP Resolution | 0.1mV < 1000mV (1mV ≥1000mV) |
ORP Accuracy | ±20 mV |
Probe Temperature Range | 32 to 140 °F (0 to 60°C) selectable |
Temperature Resolution | 0.1° (1° when >100°) |
Temperature Accuracy | ±1°C |
Standard Electrode | Polycarbonate body housing, 12mm diameter, 4.4"/111mm length, single-junction gelled Ag/AgCl reference (sealed) with ceramic pin/pellon junction, ASI type VIII glass, full range pH sensor, 0.095" Platinum disc ORP sensor, and integral thermistor |
Operating Range | 32 to 140°F (0 to 60°C) |
Power Requirements | 2 x CR2032 3V Batteries (included) |
Battery Life | >25 Hours Typical (without use of back-lighting) |
Battery Saving Feature | After 8 minutes of non-use, low battery indicator at < 10% remaining |
Dimensions | 10.25 x 2.5 x 1" (26 x 6.4 x 2.5 cm) |
Weight | 4.5 ounces (127 grams) |
Calibration | User-selected 1, 2 or 3-point calibration |
Automatic Buffer Recognition | User-selected standard buffer sets: USA 4.01 / 7.00 / 10.01 or NIST 4.01 / 6.86 / 9.18 |
pH Range | 0.00 to 14.00 pH units |
pH Resolution | 0.01 pH units |
pH Accuracy | ±0.02 pH units |
ORP Range | -1800 to 1800 mV |
ORP Resolution | 0.1mV < 1000mV (1mV ≥1000mV) |
ORP Accuracy | ±20 mV |
Probe Temperature Range | 32 to 140 °F (0 to 60°C) selectable |
Temperature Resolution | 0.1° (1° when >100°) |
Temperature Accuracy | ±1°C |
Standard Electrode | Polycarbonate body housing, 12mm diameter, 4.4"/111mm length, single-junction gelled Ag/AgCl reference (sealed) with ceramic pin/pellon junction, ASI type VIII glass, full range pH sensor, 0.095" Platinum disc ORP sensor, and integral thermistor |
Operating Range | 32 to 140°F (0 to 60°C) |
Power Requirements | 2 x CR2032 3V Batteries (included) |
Battery Life | >25 Hours Typical (without use of back-lighting) |
Battery Saving Feature | After 8 minutes of non-use, low battery indicator at < 10% remaining |
Dimensions | 10.25 x 2.5 x 1" (26 x 6.4 x 2.5 cm) |
Weight | 4.5 ounces (127 grams) |
Calibration | User-selected 1, 2 or 3-point calibration |
Automatic Buffer Recognition | User-selected standard buffer sets: USA 4.01 / 7.00 / 10.01 or NIST 4.01 / 6.86 / 9.18 |