Measure, document, and analyze all indoor air quality parameters. Additionally, this air flow kit is ideal for testing, adjusting, balancing, commissioning professionals, and cleanroom performance tester.
Measure, document, and analyze all indoor air quality parameters. Additionally, this air flow kit is ideal for testing, adjusting, balancing, commissioning professionals, and cleanroom performance tester.
Features
Applications
Temperature - NTC | |
Measuring Range | -40 to 302°F (-40 to 150°C) |
Accuracy | ±0.2°C ±1 Digit (-25 to 74.9°C) ±0.4°C ±1 Digit (-40 to -25.1°C) ±0.4°C ±1 Digit (75 to 99.9°C) ±0.5% of mv ±1 Digit (Remaining Range) |
Resolution | 0.1°C |
Temperature - TC Type K (NiCr-Ni) | |
Measuring Range | (-200 to 1370°C) |
Accuracy | ±(0.3°C + 0.1% of mv) ±1 Digit |
Resolution | 0.1°C |
Differential Pressure (Internal Sensor) - Piezoresistive | |
Measuring Range | -100 to 200 hPa |
Accuracy | ±(0.3 Pa + 1% of mv) ±1 Digit (0 to 25 hPa) ±(0.1 hPa + 1.5% of mv) ±1 Digit (25.001 to 200 hPa) |
Resolution | 0.0001 hPa |
Absolute Pressure (Internal Sensor and External Probe) | |
Measuring Range | 700 to 1100 hPa |
Accuracy | ±3 hPa |
Resolution | 0.1 hPa |
General Specifications | |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Memory | 2 GB |
Interface | Bluetooth® USB WLAN |
Power Supply | Rechargeable li-ion battery (5550 mAh) |
Display Type | 5.0" touch display, HD 1280, 720 pixels, IPS (160 k) |
Battery Life | Approximately 10 hrs continuous operation |
Connectable Probes | 4 x digital Bluetooth® probe or testo Smart Probe 2 x digital probe with fixed cable or temperature probe NTC with fixed cable (via Testo Universal Connector - TUC) 2 x temperature probe TC type K with fixed cable |
Camera Image Size | Main camera: 8.0 MP Front camera: 5.0 MP |
Protection Class | IP40 |
Operating Temperature | 23 to 113°F (-5 to 45°C) |
Dimensions | 8.3 x 3.7 x 1.5" (210 x 95 x 39 mm) |
Weight | 1.12 lbs (510 g) |
Measure, analyze, and document all indoor air quality and comfort level parameters with this universal IAQ instrument. Additionally, this instrument comes equipped with a built-in measurement assistant which supplies optimum support for carrying out airflow and comfort level measurements in conformity with the standards.
Use this carrying case to store and protect your air flow measurement equipment. Additionally, it features compartments, which offers space for the appropriate measuring instrument, accessories, and probes.
The readings of the hot wire probe are transmitted to your measuring instrument via Bluetooth, up to 65'. The hot wire probe is equipped with a telescopic extension, which can be extended to 3'. Includes temperature and humidity sensor.
This is a great addition to the 0554 2160 cable handle. Features intuitive technology that provides a parallel determination of air velocity, volume flow and air temperature.
Thanks to the 90° angle, you can even carry out convenient measurements at ceiling outlets. Use the angle adapter to attach the telescope to an air velocity probe connected to a universal Bluetooth or wired cable handle. For ceiling outlets.
Used to measure flow velocity. Measuring range is 198 to 19680ft/min. Operating temperature is 32 to 1112°F (0 - 600°C).
Click on a category to view a selection of compatible accessories with the Testo 400 Air Flow Kit for TAB/commissioning professionals.
Temperature - NTC | |
Measuring Range | -40 to 302°F (-40 to 150°C) |
Accuracy | ±0.2°C ±1 Digit (-25 to 74.9°C) ±0.4°C ±1 Digit (-40 to -25.1°C) ±0.4°C ±1 Digit (75 to 99.9°C) ±0.5% of mv ±1 Digit (Remaining Range) |
Resolution | 0.1°C |
Temperature - TC Type K (NiCr-Ni) | |
Measuring Range | (-200 to 1370°C) |
Accuracy | ±(0.3°C + 0.1% of mv) ±1 Digit |
Resolution | 0.1°C |
Differential Pressure (Internal Sensor) - Piezoresistive | |
Measuring Range | -100 to 200 hPa |
Accuracy | ±(0.3 Pa + 1% of mv) ±1 Digit (0 to 25 hPa) ±(0.1 hPa + 1.5% of mv) ±1 Digit (25.001 to 200 hPa) |
Resolution | 0.0001 hPa |
Absolute Pressure (Internal Sensor and External Probe) | |
Measuring Range | 700 to 1100 hPa |
Accuracy | ±3 hPa |
Resolution | 0.1 hPa |
General Specifications | |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Memory | 2 GB |
Interface | Bluetooth® USB WLAN |
Power Supply | Rechargeable li-ion battery (5550 mAh) |
Display Type | 5.0" touch display, HD 1280, 720 pixels, IPS (160 k) |
Battery Life | Approximately 10 hrs continuous operation |
Connectable Probes | 4 x digital Bluetooth® probe or testo Smart Probe 2 x digital probe with fixed cable or temperature probe NTC with fixed cable (via Testo Universal Connector - TUC) 2 x temperature probe TC type K with fixed cable |
Camera Image Size | Main camera: 8.0 MP Front camera: 5.0 MP |
Protection Class | IP40 |
Operating Temperature | 23 to 113°F (-5 to 45°C) |
Dimensions | 8.3 x 3.7 x 1.5" (210 x 95 x 39 mm) |
Weight | 1.12 lbs (510 g) |
Measure, analyze, and document all indoor air quality and comfort level parameters with this universal IAQ instrument. Additionally, this instrument comes equipped with a built-in measurement assistant which supplies optimum support for carrying out airflow and comfort level measurements in conformity with the standards.
Use this carrying case to store and protect your air flow measurement equipment. Additionally, it features compartments, which offers space for the appropriate measuring instrument, accessories, and probes.
The readings of the hot wire probe are transmitted to your measuring instrument via Bluetooth, up to 65'. The hot wire probe is equipped with a telescopic extension, which can be extended to 3'. Includes temperature and humidity sensor.
This is a great addition to the 0554 2160 cable handle. Features intuitive technology that provides a parallel determination of air velocity, volume flow and air temperature.
Thanks to the 90° angle, you can even carry out convenient measurements at ceiling outlets. Use the angle adapter to attach the telescope to an air velocity probe connected to a universal Bluetooth or wired cable handle. For ceiling outlets.
Used to measure flow velocity. Measuring range is 198 to 19680ft/min. Operating temperature is 32 to 1112°F (0 - 600°C).
Click on a category to view a selection of compatible accessories with the Testo 400 Air Flow Kit for TAB/commissioning professionals.