Featuring a two-channel, 100 MHz bandwidth module with a 1 GSa/s maximum sample rate. It offers and supports multiple powerful triggering modes including serial bus triggering, along with serial bus decoding for IIC, SPI, UART, CAN, LIN bus types. Includes History waveform recording and sequential triggering that enable extended waveform recording and analysis.
Featuring a two-channel, 100 MHz bandwidth module with a 1 GSa/s maximum sample rate. It offers and supports multiple powerful triggering modes including serial bus triggering, along with serial bus decoding for IIC, SPI, UART, CAN, LIN bus types. Includes History waveform recording and sequential triggering that enable extended waveform recording and analysis.
A high speed display technology that provides excellent signal clarity, fidelity and performance, with a low system noise floor. It comes with a minimum vertical input range of 500 uV/div, an innovative digital trigger system with high sensitivity and low jitter, and a waveform capture rate of 400,000 frames/ sec (sequence mode). It also employs a 256-level intensity grading display function and a color temperature display mode.
Features
Record Length
Up to 14 Mpts (single channel/pair mode), 7 Mpts/CH (two channels/ pair mode). Using hardware-based Zoom technologies and max record length of up to 14 Mpts, users are able to over-sample to capture longer time periods at higher resolution and use the zoom feature to see more details within each signal.
Excellent Something Rate
Two channel series have one 1 GSa/s ADC, four channel series have two 1 GSa/s ADCs. When all channels are enabled, each channel has a maximum sample rate of 500 MSa/s. When a single channel per ADC is active, it has sample rate of 1 GSa/s.
Waveform Capture Rate
With a waveform capture rate of up to 400,000 wfm/s (sequence mode), the oscilloscope can easily capture the unusual or low-probability events.
New generation high speed display technology
Math Functions
FFT, addition, subtraction, multiplication, division, integration, differential, square root which enables speedy extraction of results from waveforms and measurements.
256-Level Intensity Grading and Color Temperature Display
Innovative display technology provides for fast refresh rates. The resulting intensity-graded trace is brighter for events that occur with more frequency and dims when the events occur with less frequency. The color temperature display is similar to the intensity- graded trace function, but the trace occurrence is represented by different colors (color "temperature") as opposed to changes in the intensity of one color. Red colors represents the more frequent events, while blue is used to mark points that occur lest frequently.
History Waveforms (History) Mode and Segmented Acquisition (Sequence)
Playback the latest triggered events using the history function. Segmented memory collection will store trigger events into multiple (Up to 80,000) memory segments. Each segment will store triggered waveforms and timestamp each frame.
Gate and Zoom Measurement
Through Gate and Zoom measurement, the user can specify an arbitrary interval of waveform data analysis and statistics. This helps avoid measurement errors that can be caused by invalid or extraneous data, greatly enhancing the measurements' validity and flexibility.
Multiple Interface Types
USB Host, USB Device (USB-TMC), LAN, Trigger Out thus allowing users to save data for external analysis and screen images for reports.
Bandwidth | 100 MHz |
Sampling Rate (Max.) | Single 1 GSa/s ADC |
Channels | 2+EXT |
Memory Depth (Max.) | 7 Mpts/CH (not interleave mode) 14 Mpts/CH (interleave mode) |
Waveform Capture Rate (Max.) | 100,000 wfm/s (normal mode), 400,000 wfm/s (sequence mode) |
Trigger Type | Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, Video |
Serial Trigger and Decoder (Standard) | IIC, SPI, UART/RS232, CAN, LIN |
I/O | USB Host, USB Device, LAN, Pass/Fail, Trigger Out, Sbus |
Display | 7" TFT-LCD (800 x 480) |
Electromagnetic Compatibility | 2004/108/EC Execution Standard EN 61326-1:2006 EN 61000-3-2:2006 + A2:2009, EN 61000-3-3:2008 |
Safety | 2006/95/EC Execution Standard EN 61010-1:2010 / EN 61010-2-030:2010 |
Power Supply | Input Voltage: 100 to 240 VAC, CAT II, Auto selection Frequency: 50/60/400 Hz Power: 25 W Max |
Dimensions | 12.28 x 5.27 x 5.91" (312 x 134 x 150 mm) |
Weight | 5.5 lbs (2.5 kg) |
Click on a category to view a selection of compatible accessories with the Teledyne LeCroy T3DSO1102 Oscilloscope, 2 Channel, 100 MHz.
Bandwidth | 100 MHz |
Sampling Rate (Max.) | Single 1 GSa/s ADC |
Channels | 2+EXT |
Memory Depth (Max.) | 7 Mpts/CH (not interleave mode) 14 Mpts/CH (interleave mode) |
Waveform Capture Rate (Max.) | 100,000 wfm/s (normal mode), 400,000 wfm/s (sequence mode) |
Trigger Type | Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, Video |
Serial Trigger and Decoder (Standard) | IIC, SPI, UART/RS232, CAN, LIN |
I/O | USB Host, USB Device, LAN, Pass/Fail, Trigger Out, Sbus |
Display | 7" TFT-LCD (800 x 480) |
Electromagnetic Compatibility | 2004/108/EC Execution Standard EN 61326-1:2006 EN 61000-3-2:2006 + A2:2009, EN 61000-3-3:2008 |
Safety | 2006/95/EC Execution Standard EN 61010-1:2010 / EN 61010-2-030:2010 |
Power Supply | Input Voltage: 100 to 240 VAC, CAT II, Auto selection Frequency: 50/60/400 Hz Power: 25 W Max |
Dimensions | 12.28 x 5.27 x 5.91" (312 x 134 x 150 mm) |
Weight | 5.5 lbs (2.5 kg) |
Click on a category to view a selection of compatible accessories with the Teledyne LeCroy T3DSO1102 Oscilloscope, 2 Channel, 100 MHz.