Teledyne LeCroy HVD3102A-NOACC High Voltage Differential Probe with Auto Zero Disconnect, 1 kV, 25 MHz

Model: HVD3102A-NOACC

Teledyne LeCroy HVD3102A-NOACC High Voltage Differential Probe with Auto Zero Disconnect, 1 kV, 25 MHz

Model: HVD3102A-NOACC

Featuring an easy-to-use design that enables for safe, precise high voltage floating measurements. It provides high CMRR over a broad frequency range to simplify measurement challenges found in noisy, high common-mode power electronic environments. Features a 1 kV safety rating, along with a bandwidth of 25 MHz.

Featuring an easy-to-use design that enables for safe, precise high voltage floating measurements. It provides high CMRR over a broad frequency range to simplify measurement challenges found in noisy, high common-mode power electronic environments. Features a 1 kV safety rating, along with a bandwidth of 25 MHz.

Your Price $2285.00 USD
Availability 8 to 9 Weeks
Quantity

Teledyne LeCroy HVD3102A-NOACC Offers

Features

  • 1kV CAT safety rated
  • 25 MHz bandwidth
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC and DC coupling
  • ProBus active probe interface with automatic scaling
  • AutoZero with auto disconnect switch
  • Wide oscilloscope compatibility

Exceptional Common-Mode Rejection Ratio

The CMRR for the probes is exceptional out to very high frequencies, greatly improving measurement capability in the noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability provides superior measurement capabilities compared to other HV differential probes.

High Precision Measurements

Provides 1% gain accuracy enabling precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement. This feature can be applied without removing the HVD3000A leads from the device under test.

Complete Probe Integration

The ProBus interface provides power and communication to the probe eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.

Teledyne LeCroy HVD3102A-NOACC Specifications

Main Specifications
Bandwidth 25 MHz
Input Coupling DC only
Input Impedance 10 MΩ || 2.5 pF (between inputs)
5 MΩ || 5.0 pF (either input to ground)
Attenuation 100x/1000x
Rise Time (10 to 90%) 14 ns
Differential Voltage Range (High Attenuation) 1500 V (DC + peak AC) from 7 to 500 V/div with up to 1500V offset
2000 V maximum typical measurable differential voltage before saturation
Differential Voltage Range (Low Attenuation) 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150V offset
Common Mode Voltage Range ±1500 V (DC + peak AC), 1000 Vrms (CAT III) (either input to ground)
Maximum Input Voltage to Earth ±2000 Vpk (nominal, either input to ground)
Maximum Safe Input 1000 Vrms CAT III per IEC/EN 61010-031/A1:2008
Sensitivity 100 mV/div to 6.9V/div (100X)
7V/div to 500V/div (1000X)
Gain Accuracy 1% (LF, guaranteed)
Slew Rate 100 V/ns (maximum)
Output Coupling AC or DC coupling
Output Termination 1 MΩ
Noise and Rejection
CMRR (Typical) DC - 60 Hz: 85 dB
1 MHz: 65 dB
5 MHz: 40 dB
20 MHz: 30 dB
Noise (Probe) 100X: <15 mVrms
1000X: <85 mVrms
(referred to input)
General Specifications
Interface ProBus
Input Lead Length 40 cm input lead length
Cable Length 2.25 m
Temperature Operating: 32 to 122°F (0 to 50°C)
Non-operating: -40 to 158°F (-40 to 70°C)
Humidity Operating: 5% to 80% RH (Non-Condensing) up to 86°F (30°C), decreasing linearly to 45% RH at 122°F (50°C)
Non-operating: 5% to 95% RH (Non-Condensing), 75% RH above 86°F (30°C), 45% RH above 104°F (40°C)
Altitude Operating: 3,000 m maximum
Non-operating: 10,000 m
Pollution Degree 2, Indoor use only
Click here for complete specifications on the Teledyne LeCroy HVD3102A-NOACC

What's included with the Teledyne LeCroy HVD3102A-NOACC

  • Teledyne LeCroy HVD3102A-NOACC High Voltage Differential Probe with Auto Zero Disconnect, 1 kV, 25 MHz

Ask a question about Teledyne LeCroy HVD3102A-NOACC High Voltage Differential Probe with Auto Zero Disconnect, 1 kV, 25 MHz

Customer Reviews for the Teledyne LeCroy HVD3102A-NOACC

Teledyne LeCroy HVD3102A-NOACC Offers

Features

  • 1kV CAT safety rated
  • 25 MHz bandwidth
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC and DC coupling
  • ProBus active probe interface with automatic scaling
  • AutoZero with auto disconnect switch
  • Wide oscilloscope compatibility

Exceptional Common-Mode Rejection Ratio

The CMRR for the probes is exceptional out to very high frequencies, greatly improving measurement capability in the noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability provides superior measurement capabilities compared to other HV differential probes.

High Precision Measurements

Provides 1% gain accuracy enabling precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement. This feature can be applied without removing the HVD3000A leads from the device under test.

Complete Probe Integration

The ProBus interface provides power and communication to the probe eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.

Teledyne LeCroy HVD3102A-NOACC Specifications

Main Specifications
Bandwidth 25 MHz
Input Coupling DC only
Input Impedance 10 MΩ || 2.5 pF (between inputs)
5 MΩ || 5.0 pF (either input to ground)
Attenuation 100x/1000x
Rise Time (10 to 90%) 14 ns
Differential Voltage Range (High Attenuation) 1500 V (DC + peak AC) from 7 to 500 V/div with up to 1500V offset
2000 V maximum typical measurable differential voltage before saturation
Differential Voltage Range (Low Attenuation) 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150V offset
Common Mode Voltage Range ±1500 V (DC + peak AC), 1000 Vrms (CAT III) (either input to ground)
Maximum Input Voltage to Earth ±2000 Vpk (nominal, either input to ground)
Maximum Safe Input 1000 Vrms CAT III per IEC/EN 61010-031/A1:2008
Sensitivity 100 mV/div to 6.9V/div (100X)
7V/div to 500V/div (1000X)
Gain Accuracy 1% (LF, guaranteed)
Slew Rate 100 V/ns (maximum)
Output Coupling AC or DC coupling
Output Termination 1 MΩ
Noise and Rejection
CMRR (Typical) DC - 60 Hz: 85 dB
1 MHz: 65 dB
5 MHz: 40 dB
20 MHz: 30 dB
Noise (Probe) 100X: <15 mVrms
1000X: <85 mVrms
(referred to input)
General Specifications
Interface ProBus
Input Lead Length 40 cm input lead length
Cable Length 2.25 m
Temperature Operating: 32 to 122°F (0 to 50°C)
Non-operating: -40 to 158°F (-40 to 70°C)
Humidity Operating: 5% to 80% RH (Non-Condensing) up to 86°F (30°C), decreasing linearly to 45% RH at 122°F (50°C)
Non-operating: 5% to 95% RH (Non-Condensing), 75% RH above 86°F (30°C), 45% RH above 104°F (40°C)
Altitude Operating: 3,000 m maximum
Non-operating: 10,000 m
Pollution Degree 2, Indoor use only
Click here for complete specifications on the Teledyne LeCroy HVD3102A-NOACC

What's included with the Teledyne LeCroy HVD3102A-NOACC

  • Teledyne LeCroy HVD3102A-NOACC High Voltage Differential Probe with Auto Zero Disconnect, 1 kV, 25 MHz

Ask a question about Teledyne LeCroy HVD3102A-NOACC High Voltage Differential Probe with Auto Zero Disconnect, 1 kV, 25 MHz

Customer Reviews for the Teledyne LeCroy HVD3102A-NOACC

More Teledyne LeCroy Products

Calibration Lab