Featuring a high-performance pressure transmitter with HART® communication protocol that is used to measure gauge pressure, as well as liquid, gas, or steam flow as well as liquid level and density of the medium. It has accuracy up to 0.075% of URL and IP66 water-proof protection. It has a measuring range of 0 to 5.8 psig.
Featuring a high-performance pressure transmitter with HART® communication protocol that is used to measure gauge pressure, as well as liquid, gas, or steam flow as well as liquid level and density of the medium. It has accuracy up to 0.075% of URL and IP66 water-proof protection. It has a measuring range of 0 to 5.8 psig.
Features
Applications
Pressure Type | Gauge pressure |
Reference Accuracy | ±0.075% F.S. |
Diaphragm Materials | Hastelloy C |
Measuring Range | 0 to 5.8 psig |
Stability | ±0.2% URL/5 year |
Ambient Temperature Effect | -4 to 176°F (-20 to 80°C) |
Working Humidity | 5 to 100% RH at 104°F |
Output Signal | 4 to 20 mA with HART |
Electrical Connection | 1/2" NPT female conduit |
Insulation Resistance | ≥20 MΩ at 100 VDC |
Process Connection | 1/4" NPT female |
Working Temperature | -40 to 180°F (-40 to 82°C) |
Testing Standard | GB/T28474/IEC60770 |
Media Temperature | Silicon oil filling: -40 to 248°F (-40 to 120°C) |
Protection Class | IP66 |
Standard/Flame Proof | 10.5 to 55 VDC |
HART Protocol | 16.5 to 55 VDC, communication load resistance 250 Ω |
Load Resistance | 0 to 2119 Ω for working condition, 250 to 600 Ω for HART |
Transmission Distance | <1000 m |
Power Consumption | ≤500 mW at 24 VDC, 20.8 mA |
Weight | About 3.43 lbs |
Pressure Type | Gauge pressure |
Reference Accuracy | ±0.075% F.S. |
Diaphragm Materials | Hastelloy C |
Measuring Range | 0 to 5.8 psig |
Stability | ±0.2% URL/5 year |
Ambient Temperature Effect | -4 to 176°F (-20 to 80°C) |
Working Humidity | 5 to 100% RH at 104°F |
Output Signal | 4 to 20 mA with HART |
Electrical Connection | 1/2" NPT female conduit |
Insulation Resistance | ≥20 MΩ at 100 VDC |
Process Connection | 1/4" NPT female |
Working Temperature | -40 to 180°F (-40 to 82°C) |
Testing Standard | GB/T28474/IEC60770 |
Media Temperature | Silicon oil filling: -40 to 248°F (-40 to 120°C) |
Protection Class | IP66 |
Standard/Flame Proof | 10.5 to 55 VDC |
HART Protocol | 16.5 to 55 VDC, communication load resistance 250 Ω |
Load Resistance | 0 to 2119 Ω for working condition, 250 to 600 Ω for HART |
Transmission Distance | <1000 m |
Power Consumption | ≤500 mW at 24 VDC, 20.8 mA |
Weight | About 3.43 lbs |