This dual combination tester verifies the functionality of personnel grounding devices like wrist, straps, foot grounders, ESD shoes, and smocks.
This dual combination tester verifies the functionality of personnel grounding devices like wrist, straps, foot grounders, ESD shoes, and smocks.
This dual combination tester has 30 V test signal that provides accurate tests that are not humidity dependent.
Features
Dual Combination Tester | |
Input Voltage and Frequency (External Adapter) | AC/DC Power Adapter Power Input: 100 to 240 VAC, 50/60 Hz Power Output: 12 VDC, 0.5 A Cable Length: 6 ft. (1.83 m) |
Operating Temperature | For 1 gigohm test limit: 70 to 85°F (21 to 30°C) For all other test limits: 41 to 85°F (5 to 30°C) |
Environmental Requirements | Indoor use only at altitudes less than 6500 ft. (2 km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% at 85°F (30°C) Maximum relative humidity of 50% at 1 gigohm setting |
Test Accuracy | ±20% for 1 gigohm footwear test limit ±10% for all other test limits |
Test Switch Voltage | 5 VDC at open circuit |
Wrist Strap and Footwear Test Voltage | 30 VDC at open circuit Test current is limited by resistors and varies on the test range setting (100 kilohms to 1 gigohm) |
Relay Contact Rating | 1 A at 30 VDC max |
Dimensions | 11.35 x 7.75 x 1.47" (288 x 197 x 37 mm) with mounting plate |
Weight | 1.2 lbs (0.5 kg) with mounting plate |
Dual Foot Plate | |
Dimensions | 13.25 x 15.25 x 1.125" (337 x 387 x 29 mm) |
Weight | 5.5 lbs (2.5 kg) |
Dual Combination Tester | |
Input Voltage and Frequency (External Adapter) | AC/DC Power Adapter Power Input: 100 to 240 VAC, 50/60 Hz Power Output: 12 VDC, 0.5 A Cable Length: 6 ft. (1.83 m) |
Operating Temperature | For 1 gigohm test limit: 70 to 85°F (21 to 30°C) For all other test limits: 41 to 85°F (5 to 30°C) |
Environmental Requirements | Indoor use only at altitudes less than 6500 ft. (2 km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% at 85°F (30°C) Maximum relative humidity of 50% at 1 gigohm setting |
Test Accuracy | ±20% for 1 gigohm footwear test limit ±10% for all other test limits |
Test Switch Voltage | 5 VDC at open circuit |
Wrist Strap and Footwear Test Voltage | 30 VDC at open circuit Test current is limited by resistors and varies on the test range setting (100 kilohms to 1 gigohm) |
Relay Contact Rating | 1 A at 30 VDC max |
Dimensions | 11.35 x 7.75 x 1.47" (288 x 197 x 37 mm) with mounting plate |
Weight | 1.2 lbs (0.5 kg) with mounting plate |
Dual Foot Plate | |
Dimensions | 13.25 x 15.25 x 1.125" (337 x 387 x 29 mm) |
Weight | 5.5 lbs (2.5 kg) |