Sauermann Si-CA 130 Kit 3BS Combustion Analyzer Kit with 12" probe, O2/CO/NO

Model: SICA 130 KIT 3BS | Order No: 27513

Sauermann Si-CA 130 Kit 3BS Combustion Analyzer Kit with 12" probe, O2/CO/NO

Model: SICA 130 KIT 3BS | Order No: 27513

Measure exhaust gasses from forklift engines with this combustion analyzer kit. In addition, this kit includes a combustion analyzer, three gas sensors, a 12" (300 mm) probe, a holster, a water trap, a power supply, a USB cable, a wireless communication module, a quick start guide, a calibration certificate, and a vinyl case.

Measure exhaust gasses from forklift engines with this combustion analyzer kit. In addition, this kit includes a combustion analyzer, three gas sensors, a 12" (300 mm) probe, a holster, a water trap, a power supply, a USB cable, a wireless communication module, a quick start guide, a calibration certificate, and a vinyl case.

Your Price $2467.47 USD
Availability 2 to 3 Weeks
Quantity

Sauermann SICA 130 KIT 3BS Offers

Compact and durable, this combustion analyzer kit features pre-calibrated field-replaceable cells and sensors to expand measurement capability. Additionally, this kit features CO sensor measurements up to 8000 ppm and automatic logging and report creation through the app or software.

Features

  • Lightweight, only 12 oz (350 g)
  • CO sensor measurement up to 8000 ppm
  • Large color touch screen
  • Field replaceable pre-calibrated sensors
  • Automatic logging and report creation through app and/or PC software
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Draft and differential pressure measurements
  • Calculated CO2% value
  • Auto pump cut-off for high CO levels (user-adjustable)
  • NOx capable with NO sensor
  • One touch pump On/Off with purge
  • PC software with wireless and USB connectivity
  • Combustion efficiency and excess air calculations
  • Graphical data display
  • Customizable gas analysis screen
  • Sample conditioning unit for low Nox and high moisture applications
  • CO and CO2 monitoring in ambient air
  • Smart air temperature probe
  • Protective rubber holster

Applications

  • Forklift engines

Sauermann SICA 130 KIT 3BS Specifications

Air Temperature Sensor: NTC or TcK
Measuring range: -4 to 248°F (-20 to 120°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±3.6°F (±2°C)
CO Sensor: Electrochemical
Measuring range: 0 to 8000 ppm
Resolution: 1 ppm

Accuracy:
±8 ppm <160 ppm
±5% rdg up to 2000 ppm
±10 rdg >2000 ppm
T90 response time: <40 seconds
CO2 Sensor: Calculated
Measuring range: 0 to 99.9%
Resolution: 0.1%
Connection Wireless: class 2 range, range frequency from 2402 to 2480 MHz with a transmit power of 1 dBm
Range up to 50' (15 m), depending on smartphone radio strength
Minimum required versions: Android 5.0, iOS 12.4, BLE 4.0- USB
Differential Temperature Sensor: Calculated
Measuring range: 0 to 2282°F (0 to 1250°C)
Resolution: 0.1°F (0.1°C)
Dimensions 7.5 x 3.5 x 4.9" (19.4 x 9.9 x 4.9 cm)
Display Color touch screen with graphing; Size: 480 x 272 pixels
Efficiency Sensor: Calculated
Measuring range: 0 to 100% (Gross/HHV)
Resolution: 0.1%
Efficiency (condensation) Sensor: Calculated
Measuring range: 0 to 125% (Net/LHV) (Gross/HHV)
Resolution: 0.1%
Environmental Conditions of Use Temperature: From 23 to 11°F (-5 to 45°C)
Hygrometry: In non-condensing conditions (<85% RH)
Maximum altitude: 6561' (2000 m)
European Union Directives 2014/53/EU (RED); 2015/863 EU (RoHS 3)
Excess Air Sensor: Calculated
Measuring range: 0 to 999%
Resolution: 1%
Flue Temperature Sensor: TcK
Measuring range: -4 to 2282°F (-20 to 1250°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±3.6°F or ±0.5% rdg (±2°C or ±0.5% rdg)
High Accuracy Draft Sensor: Semiconductor
Measuring range: 500 Pa
Resolution: 0.1 Pa

Accuracy:
±0.5 Pa <10 Pa
±3 Pa up to 150 Pa
±2% rdg >150 Pa
Keypad 1 On-Off key
Languages English, French, German, Spanish, Italian, Portuguese, Chinese
Low NO Sensor: Electrochemical
Measuring range: 0 to 300 ppm
Resolution: 0.1 ppm

Accuracy:
±1.5 ppm <30 ppm
±5% rdg >30 ppm
T90 response time: <40 seconds
Low NOx Sensor: Calculated
Measuring range: 0 to 450 ppm
Resolution: 0.1 ppm
Material ABS-PC
NO Sensor: Electrochemical
Measuring range: 0 to 5000 ppm
Resolution: 1 ppm

Accuracy:
±5 ppm <100 ppm
±5% rdg >100 ppm
T90 response time: <40 seconds
NOx Sensor: Calculated
Measuring range: 0 to 7500 ppm
Resolution: 1 ppm
O2 Sensor: Electrochemical
Measuring range: 0 to 25%
Resolution: 0.01%
Accuracy: ±0.2% vol
T90 response time: <30 seconds
Power Supply: Rechargeable battery, USB power supply Li-Ion 5100 mA/h 3.6 V battery/power supply voltage of the mains unit: 100 to 240 V AC, 50 to 60 Hz
Mains unit: 5 V DC/2 A
Battery life: >8 hours; Charging time: Fully charge: <6.5 hours; 50%: <2.5 hours
Pressure/Draft Sensor: Semiconductor

Measuring range:
-80 to 80 inH2O
-200 to 200 mbar

Resolution:
0.001 inH2O
0.01 mbar

Accuracy:
±1% rdg ±0.012 inH2O
±1% rdg ±0.03 mbar
Protection IP42
Regulations EN 50379-1 and EN 50379-2; UNI 7129; UNI 11137; UNI 10389; UNI 10845; UL & cUL Certification; BS 7967:2015; BS EN 50543:2011; UNE 60670-10; ES.02173.ES
Stack Gas Velocity Sensor: Calculated

Measuring range:
0 to 19,500 fpm
0 to 99 m/s

Resolution:
1 fpm
0.1 m/s
Storage Temperature From -4 to 122°F (-20 to 50°C)
Weight 12 oz (350 g)
Click here for complete specifications on the Sauermann SICA 130 KIT 3BS

What's included with the Sauermann SICA 130 KIT 3BS

  • Combustion Analyzer
  • Calibration Certificate
  • O2 Gas Sensor
  • CO Gas Sensor
  • Protective Rubber Holster
  • Flue Gas Probe with Dual Hose
  • Water Trap with Filter
  • USB Cable
  • Mobile App
  • Internal Wireless Communication Module
  • AC Power Supply/Charger
  • Vinyl Carrying Case
  • Quick Start Guide
  • Two-Year Warranty

Ask a question about Sauermann Si-CA 130 Kit 3BS Combustion Analyzer Kit with 12" probe, O2/CO/NO

Customer Reviews for the Sauermann SICA 130 KIT 3BS

Sauermann SICA 130 KIT 3BS Offers

Compact and durable, this combustion analyzer kit features pre-calibrated field-replaceable cells and sensors to expand measurement capability. Additionally, this kit features CO sensor measurements up to 8000 ppm and automatic logging and report creation through the app or software.

Features

  • Lightweight, only 12 oz (350 g)
  • CO sensor measurement up to 8000 ppm
  • Large color touch screen
  • Field replaceable pre-calibrated sensors
  • Automatic logging and report creation through app and/or PC software
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Draft and differential pressure measurements
  • Calculated CO2% value
  • Auto pump cut-off for high CO levels (user-adjustable)
  • NOx capable with NO sensor
  • One touch pump On/Off with purge
  • PC software with wireless and USB connectivity
  • Combustion efficiency and excess air calculations
  • Graphical data display
  • Customizable gas analysis screen
  • Sample conditioning unit for low Nox and high moisture applications
  • CO and CO2 monitoring in ambient air
  • Smart air temperature probe
  • Protective rubber holster

Applications

  • Forklift engines

Sauermann SICA 130 KIT 3BS Specifications

Air Temperature Sensor: NTC or TcK
Measuring range: -4 to 248°F (-20 to 120°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±3.6°F (±2°C)
CO Sensor: Electrochemical
Measuring range: 0 to 8000 ppm
Resolution: 1 ppm

Accuracy:
±8 ppm <160 ppm
±5% rdg up to 2000 ppm
±10 rdg >2000 ppm
T90 response time: <40 seconds
CO2 Sensor: Calculated
Measuring range: 0 to 99.9%
Resolution: 0.1%
Connection Wireless: class 2 range, range frequency from 2402 to 2480 MHz with a transmit power of 1 dBm
Range up to 50' (15 m), depending on smartphone radio strength
Minimum required versions: Android 5.0, iOS 12.4, BLE 4.0- USB
Differential Temperature Sensor: Calculated
Measuring range: 0 to 2282°F (0 to 1250°C)
Resolution: 0.1°F (0.1°C)
Dimensions 7.5 x 3.5 x 4.9" (19.4 x 9.9 x 4.9 cm)
Display Color touch screen with graphing; Size: 480 x 272 pixels
Efficiency Sensor: Calculated
Measuring range: 0 to 100% (Gross/HHV)
Resolution: 0.1%
Efficiency (condensation) Sensor: Calculated
Measuring range: 0 to 125% (Net/LHV) (Gross/HHV)
Resolution: 0.1%
Environmental Conditions of Use Temperature: From 23 to 11°F (-5 to 45°C)
Hygrometry: In non-condensing conditions (<85% RH)
Maximum altitude: 6561' (2000 m)
European Union Directives 2014/53/EU (RED); 2015/863 EU (RoHS 3)
Excess Air Sensor: Calculated
Measuring range: 0 to 999%
Resolution: 1%
Flue Temperature Sensor: TcK
Measuring range: -4 to 2282°F (-20 to 1250°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±3.6°F or ±0.5% rdg (±2°C or ±0.5% rdg)
High Accuracy Draft Sensor: Semiconductor
Measuring range: 500 Pa
Resolution: 0.1 Pa

Accuracy:
±0.5 Pa <10 Pa
±3 Pa up to 150 Pa
±2% rdg >150 Pa
Keypad 1 On-Off key
Languages English, French, German, Spanish, Italian, Portuguese, Chinese
Low NO Sensor: Electrochemical
Measuring range: 0 to 300 ppm
Resolution: 0.1 ppm

Accuracy:
±1.5 ppm <30 ppm
±5% rdg >30 ppm
T90 response time: <40 seconds
Low NOx Sensor: Calculated
Measuring range: 0 to 450 ppm
Resolution: 0.1 ppm
Material ABS-PC
NO Sensor: Electrochemical
Measuring range: 0 to 5000 ppm
Resolution: 1 ppm

Accuracy:
±5 ppm <100 ppm
±5% rdg >100 ppm
T90 response time: <40 seconds
NOx Sensor: Calculated
Measuring range: 0 to 7500 ppm
Resolution: 1 ppm
O2 Sensor: Electrochemical
Measuring range: 0 to 25%
Resolution: 0.01%
Accuracy: ±0.2% vol
T90 response time: <30 seconds
Power Supply: Rechargeable battery, USB power supply Li-Ion 5100 mA/h 3.6 V battery/power supply voltage of the mains unit: 100 to 240 V AC, 50 to 60 Hz
Mains unit: 5 V DC/2 A
Battery life: >8 hours; Charging time: Fully charge: <6.5 hours; 50%: <2.5 hours
Pressure/Draft Sensor: Semiconductor

Measuring range:
-80 to 80 inH2O
-200 to 200 mbar

Resolution:
0.001 inH2O
0.01 mbar

Accuracy:
±1% rdg ±0.012 inH2O
±1% rdg ±0.03 mbar
Protection IP42
Regulations EN 50379-1 and EN 50379-2; UNI 7129; UNI 11137; UNI 10389; UNI 10845; UL & cUL Certification; BS 7967:2015; BS EN 50543:2011; UNE 60670-10; ES.02173.ES
Stack Gas Velocity Sensor: Calculated

Measuring range:
0 to 19,500 fpm
0 to 99 m/s

Resolution:
1 fpm
0.1 m/s
Storage Temperature From -4 to 122°F (-20 to 50°C)
Weight 12 oz (350 g)
Click here for complete specifications on the Sauermann SICA 130 KIT 3BS

What's included with the Sauermann SICA 130 KIT 3BS

  • Combustion Analyzer
  • Calibration Certificate
  • O2 Gas Sensor
  • CO Gas Sensor
  • Protective Rubber Holster
  • Flue Gas Probe with Dual Hose
  • Water Trap with Filter
  • USB Cable
  • Mobile App
  • Internal Wireless Communication Module
  • AC Power Supply/Charger
  • Vinyl Carrying Case
  • Quick Start Guide
  • Two-Year Warranty

Ask a question about Sauermann Si-CA 130 Kit 3BS Combustion Analyzer Kit with 12" probe, O2/CO/NO

Customer Reviews for the Sauermann SICA 130 KIT 3BS

More Sauermann Products

Calibration Lab