Cost effective, high-precision and stable transmitter for measuring velocity. The devices have a calorimetric sensor and long-term stability. The range and signal can be configured easily without the use of additional software using dip switches.
Cost effective, high-precision and stable transmitter for measuring velocity. The devices have a calorimetric sensor and long-term stability. The range and signal can be configured easily without the use of additional software using dip switches.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Features
Applications
Air Flow Rate Measurement | |
Measurement Technique | Calorimetric |
Measurement Range | 2 m/s; 5 m/s; 10 m/s; 15 m/s; 20 m/s |
Measuring Medium | Air and non-aggressive gases |
Accuracy | ±3.0% full-scale with 73°F (23°C) ±3 K, 45% RH, 1013 mbar |
Influence of Installation Position | <3 % of measurement with <10° |
Measurement Interval | 1 s |
Pressure Resistance | 10 bar |
Jump Response | τ90 after 3 s |
Analog Outputs | |
Number | 1 |
Analog Output Type | 4 to 20 mA or 0 to 10 V |
Load | Minimum: <500 Ω (current output) Maximum: >10 kΩ (voltage output) |
General | |
Range of Application | 32 to 122°F (0 to 50°C) (housing) 32 to 176°F (0 to 80°C) (medium) |
Storage Conditions | -4 to 140°F (-20 to 60°C) |
Power Supply | 8 to 35 VDC or 12 to 30 VAC 50/60 Hz |
Current Consumption | <200 mA |
Circuit Type | 3-wire |
Mounting Position | Sensor at 90° angle to flow |
Configuration | Via integrated DIP switch |
Conformity | |
IP Protection | IP65 |
CE/EMC Compatibility | EMC Directive 2004/108/EC |
Housing/Mechanical | |
Housing Material | Polycarbonate |
Dimensions | 4.1 x 2.75 x 1.26" (105 x 70 x 32 mm) |
Electrical Connections | Screw terminals |
Cable Gland | M12 x 1.5 (Ø cable 0.1 to 0.25" [3 to 6.5 mm]) |
Weight | Duct version: 5.8 oz (165 g) Cable version: 9.17 oz (260 g) |
Air Flow Rate Measurement | |
Measurement Technique | Calorimetric |
Measurement Range | 2 m/s; 5 m/s; 10 m/s; 15 m/s; 20 m/s |
Measuring Medium | Air and non-aggressive gases |
Accuracy | ±3.0% full-scale with 73°F (23°C) ±3 K, 45% RH, 1013 mbar |
Influence of Installation Position | <3 % of measurement with <10° |
Measurement Interval | 1 s |
Pressure Resistance | 10 bar |
Jump Response | τ90 after 3 s |
Analog Outputs | |
Number | 1 |
Analog Output Type | 4 to 20 mA or 0 to 10 V |
Load | Minimum: <500 Ω (current output) Maximum: >10 kΩ (voltage output) |
General | |
Range of Application | 32 to 122°F (0 to 50°C) (housing) 32 to 176°F (0 to 80°C) (medium) |
Storage Conditions | -4 to 140°F (-20 to 60°C) |
Power Supply | 8 to 35 VDC or 12 to 30 VAC 50/60 Hz |
Current Consumption | <200 mA |
Circuit Type | 3-wire |
Mounting Position | Sensor at 90° angle to flow |
Configuration | Via integrated DIP switch |
Conformity | |
IP Protection | IP65 |
CE/EMC Compatibility | EMC Directive 2004/108/EC |
Housing/Mechanical | |
Housing Material | Polycarbonate |
Dimensions | 4.1 x 2.75 x 1.26" (105 x 70 x 32 mm) |
Electrical Connections | Screw terminals |
Cable Gland | M12 x 1.5 (Ø cable 0.1 to 0.25" [3 to 6.5 mm]) |
Weight | Duct version: 5.8 oz (165 g) Cable version: 9.17 oz (260 g) |