Uses a plug-in style galvanic sensor, this oxygen monitor manages with or without a controller and has 115 VAC operation with a 65.6' (20 m) sensor cable. Additionally, it has 0 to 25% volume with 0.1% increments and two preset alarms.
Uses a plug-in style galvanic sensor, this oxygen monitor manages with or without a controller and has 115 VAC operation with a 65.6' (20 m) sensor cable. Additionally, it has 0 to 25% volume with 0.1% increments and two preset alarms.
Features
Applications
Oxygen (O2) | Detection Principle: Galvanic cell Detection Range: 0 to 25% volume Indication Accuracy: Within ±0.7% volume |
Sampling Method | Diffusion or remote sampling method |
Display | Digital LCD (3 digits, 7 segments / green, orange, red) (For alkaline battery version, the back light will be OFF during normal operation) |
Display of Alarm | 1st gas alarm: gas concentration reading blinks, flashing AL 1 icon, orange back light, buzzer 2nd gas alarm: gas concentration reading blinks, flashing AL 2 icon, red back light, buzzer |
Display of Trouble Alarm | Buzzer/flashing of red error message |
Operating Temperature and Humidity | 0 to 104°F (-17 to 40°C), 0 to 90% RH (non-condensing) |
Alarm Levels | Two preset alarms (L-LL), alarm 1 = 19.5% volume, alarm 2 = 18.0% volume (other settings available) |
Response Time | 90% response within 30 seconds (T90) |
Display Resolution | 0.1% volume |
Dimensions | Body: approximately 3.15 x 4.72 x 1.2" (80 x 120 x 35.5 mm) |
Weight | Approximately 0.5 lbs (0.23 kg) |
Oxygen (O2) | Detection Principle: Galvanic cell Detection Range: 0 to 25% volume Indication Accuracy: Within ±0.7% volume |
Sampling Method | Diffusion or remote sampling method |
Display | Digital LCD (3 digits, 7 segments / green, orange, red) (For alkaline battery version, the back light will be OFF during normal operation) |
Display of Alarm | 1st gas alarm: gas concentration reading blinks, flashing AL 1 icon, orange back light, buzzer 2nd gas alarm: gas concentration reading blinks, flashing AL 2 icon, red back light, buzzer |
Display of Trouble Alarm | Buzzer/flashing of red error message |
Operating Temperature and Humidity | 0 to 104°F (-17 to 40°C), 0 to 90% RH (non-condensing) |
Alarm Levels | Two preset alarms (L-LL), alarm 1 = 19.5% volume, alarm 2 = 18.0% volume (other settings available) |
Response Time | 90% response within 30 seconds (T90) |
Display Resolution | 0.1% volume |
Dimensions | Body: approximately 3.15 x 4.72 x 1.2" (80 x 120 x 35.5 mm) |
Weight | Approximately 0.5 lbs (0.23 kg) |