Optris CT Laser LT Infrared Thermometer, -58 to 1787°F, 0.63" at 47.2"

Model: OPTCTLLTSF

Optris CT Laser LT Infrared Thermometer, -58 to 1787°F, 0.63" at 47.2"

Model: OPTCTLLTSF

Ideal for non-metallic surfaces, this infrared thermometer features a two-piece sensor with a separate electronic box, programming keys, and a display. In addition, this thermometer measures a range of -58 to 1787°F (-50 to 975°C) and features a selectable focus of 0.63" at 47.2" (16 mm at 1200 mm).

Ideal for non-metallic surfaces, this infrared thermometer features a two-piece sensor with a separate electronic box, programming keys, and a display. In addition, this thermometer measures a range of -58 to 1787°F (-50 to 975°C) and features a selectable focus of 0.63" at 47.2" (16 mm at 1200 mm).

Your Price $890.00 USD
Availability 15+ Weeks
Quantity

Optris OPTCTLLTSF Offers

Features

  • Low and high temperature measurements of smallest spots
  • Double laser aiming marks real spot location and spot size at any distance
  • Optics 75:1 with selectable focus
  • Usable up to 185°F (85°C) ambient temperature without cooling and automatic laser switch off at 122°F (50°C)
  • Selectable analog outputs 0/4 to 20 mA, 0 to 5/10 V, thermocouple type K or J

Applications

  • Non-metallic surfaces

Optris OPTCTLLTSF Specifications

Measurment Range -58 to 1787°F (-50 to 975°C)
Selectable Focus*
*4)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C)
0.63" at 47.2" (16 mm at 1200 mm)
Spectral Range 8 to 14 µm
Optical Resolution (90% Energy) 75:1
System Accuracy at Ambient Temperature 73 ±9°F (23 ±5°C) ±1% or ±1.8°F (±1% or ±1°C)*
*1)Whichever is greater and at object temperatures >32°F (0°C), ε = 1
Repeatability at Ambient Temperature 73 ±9°F (23 ±5°C) ±0.5% or ±0.9°F (±0.5% or ±0.5°C)*
*2)Whichever is greater and at object temperatures >32°F (0°C), ε = 1
Response Time (90% signal)*
*5)With dynamic adaption at low signal levels
120 ms
Emissivity/Gain 0.1 to 1.1
IR Window Correction 0.1 to 1
Signal Processing Peak hold, valley hold, average; extended hold function with threshold and hysteresis
Software optris® Compact Connect
Inputs Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions)
Output Analog: Channel 1: 0/4 to 20 mA, 0 to 5/10 V, thermocouple J, K, Channel 2: sensing head temperature (-40 to 185°F [-40 to 85°C) as 0 to 5 V or 0 to 10 V), alarm output
Alarm: 24 V / 50 mA (open collector)
Digital: USB, RS232, RS485, CAN, Profibus DP
Impedances: mA maximum 500 Ω (with 5 to 36 V DC) mV minimum 100 kΩ load impedance, thermocouple 20 Ω
Current Draw (Laser) Maximum 160 mA
Laser 635 nm 1 mW, ON/OFF via electronic box or software
Environmental Rating IP 65 (NEMA-4)
Temperature Ambient*: -4 to 185°F (-20 to 85°C), 122°F (50°C) with laser ON

Storage:
Sensing head: -4 to 257°F (-40 to 125°C)
Electronics: -40 to 185°F (-40 to 85°C)
*3)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C)
Relative Humidity 10 to 95%, non condensing
Vibration IEC 68-2-6: 3 G, 11 to 200 Hz, any axis
Shock IEC 68-2-27: 50 G, 11 ms, any axis
Power Supply 8 to 36 V DC
Dimensions Sensing head: 0.39 x ø2.17" (100 x ø55 mm)
Electronics: 4.8 x 2.76 x 1.18" (122 x 70 x 30 mm)
Cable length: 9.8 ft (3 m)
Weight Sensing head: 21.2 oz (600 g)
Electronics: 14.8 oz (420 g)
Click here for complete specifications on the Optris OPTCTLLTSF

What's included with the Optris OPTCTLLTSF

  • Infrared Thermometer
  • Sensing Head with Connection Cable and Electronic Box
  • Mounting Nut and Mounting Bracket
  • Manual
  • Two-Year Warranty

Ask a question about Optris CT Laser LT Infrared Thermometer, -58 to 1787°F, 0.63" at 47.2"

Customer Reviews for the Optris OPTCTLLTSF

Optris OPTCTLLTSF Offers

Features

  • Low and high temperature measurements of smallest spots
  • Double laser aiming marks real spot location and spot size at any distance
  • Optics 75:1 with selectable focus
  • Usable up to 185°F (85°C) ambient temperature without cooling and automatic laser switch off at 122°F (50°C)
  • Selectable analog outputs 0/4 to 20 mA, 0 to 5/10 V, thermocouple type K or J

Applications

  • Non-metallic surfaces

Optris OPTCTLLTSF Specifications

Measurment Range -58 to 1787°F (-50 to 975°C)
Selectable Focus*
*4)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C)
0.63" at 47.2" (16 mm at 1200 mm)
Spectral Range 8 to 14 µm
Optical Resolution (90% Energy) 75:1
System Accuracy at Ambient Temperature 73 ±9°F (23 ±5°C) ±1% or ±1.8°F (±1% or ±1°C)*
*1)Whichever is greater and at object temperatures >32°F (0°C), ε = 1
Repeatability at Ambient Temperature 73 ±9°F (23 ±5°C) ±0.5% or ±0.9°F (±0.5% or ±0.5°C)*
*2)Whichever is greater and at object temperatures >32°F (0°C), ε = 1
Response Time (90% signal)*
*5)With dynamic adaption at low signal levels
120 ms
Emissivity/Gain 0.1 to 1.1
IR Window Correction 0.1 to 1
Signal Processing Peak hold, valley hold, average; extended hold function with threshold and hysteresis
Software optris® Compact Connect
Inputs Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions)
Output Analog: Channel 1: 0/4 to 20 mA, 0 to 5/10 V, thermocouple J, K, Channel 2: sensing head temperature (-40 to 185°F [-40 to 85°C) as 0 to 5 V or 0 to 10 V), alarm output
Alarm: 24 V / 50 mA (open collector)
Digital: USB, RS232, RS485, CAN, Profibus DP
Impedances: mA maximum 500 Ω (with 5 to 36 V DC) mV minimum 100 kΩ load impedance, thermocouple 20 Ω
Current Draw (Laser) Maximum 160 mA
Laser 635 nm 1 mW, ON/OFF via electronic box or software
Environmental Rating IP 65 (NEMA-4)
Temperature Ambient*: -4 to 185°F (-20 to 85°C), 122°F (50°C) with laser ON

Storage:
Sensing head: -4 to 257°F (-40 to 125°C)
Electronics: -40 to 185°F (-40 to 85°C)
*3)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C)
Relative Humidity 10 to 95%, non condensing
Vibration IEC 68-2-6: 3 G, 11 to 200 Hz, any axis
Shock IEC 68-2-27: 50 G, 11 ms, any axis
Power Supply 8 to 36 V DC
Dimensions Sensing head: 0.39 x ø2.17" (100 x ø55 mm)
Electronics: 4.8 x 2.76 x 1.18" (122 x 70 x 30 mm)
Cable length: 9.8 ft (3 m)
Weight Sensing head: 21.2 oz (600 g)
Electronics: 14.8 oz (420 g)
Click here for complete specifications on the Optris OPTCTLLTSF

What's included with the Optris OPTCTLLTSF

  • Infrared Thermometer
  • Sensing Head with Connection Cable and Electronic Box
  • Mounting Nut and Mounting Bracket
  • Manual
  • Two-Year Warranty

Ask a question about Optris CT Laser LT Infrared Thermometer, -58 to 1787°F, 0.63" at 47.2"