Ideal for non-metallic surfaces, this infrared thermometer features a two-piece sensor with a separate electronic box, programming keys, and a display. In addition, this thermometer measures a range of -58 to 1787°F (-50 to 975°C) and features a selectable focus of 0.11" at 7.87" (2.75 mm at 200 mm).
Ideal for non-metallic surfaces, this infrared thermometer features a two-piece sensor with a separate electronic box, programming keys, and a display. In addition, this thermometer measures a range of -58 to 1787°F (-50 to 975°C) and features a selectable focus of 0.11" at 7.87" (2.75 mm at 200 mm).
Features
Applications
Measurment Range | -58 to 1787°F (-50 to 975°C) |
Selectable Focus* *4)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C) |
0.11" at 7.87" (2.75 mm at 200 mm) |
Spectral Range | 8 to 14 µm |
Optical Resolution (90% Energy) | 75:1 |
System Accuracy at Ambient Temperature 73 ±9°F (23 ±5°C) | ±1% or ±1.8°F (±1% or ±1°C)* *1)Whichever is greater and at object temperatures >32°F (0°C), ε = 1 |
Repeatability at Ambient Temperature 73 ±9°F (23 ±5°C) | ±0.5% or ±0.9°F (±0.5% or ±0.5°C)* *2)Whichever is greater and at object temperatures >32°F (0°C), ε = 1 |
Response Time (90% signal)* *5)With dynamic adaption at low signal levels |
120 ms |
Emissivity/Gain | 0.1 to 1.1 |
IR Window Correction | 0.1 to 1 |
Signal Processing | Peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software | optris® Compact Connect |
Inputs | Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) |
Output | Analog: Channel 1: 0/4 to 20 mA, 0 to 5/10 V, thermocouple J, K, Channel 2: sensing head temperature (-40 to 185°F [-40 to 85°C) as 0 to 5 V or 0 to 10 V), alarm output Alarm: 24 V / 50 mA (open collector) Digital: USB, RS232, RS485, CAN, Profibus DP Impedances: mA maximum 500 Ω (with 5 to 36 V DC) mV minimum 100 kΩ load impedance, thermocouple 20 Ω |
Current Draw (Laser) | Maximum 160 mA |
Laser 635 nm | 1 mW, ON/OFF via electronic box or software |
Environmental Rating | IP 65 (NEMA-4) |
Temperature | Ambient*: -4 to 185°F (-20 to 85°C), 122°F (50°C) with laser ON Storage: Sensing head: -4 to 257°F (-40 to 125°C) Electronics: -40 to 185°F (-40 to 85°C) *3)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C) |
Relative Humidity | 10 to 95%, non condensing |
Vibration | IEC 68-2-6: 3 G, 11 to 200 Hz, any axis |
Shock | IEC 68-2-27: 50 G, 11 ms, any axis |
Power Supply | 8 to 36 V DC |
Dimensions | Sensing head: 0.39 x ø2.17" (100 x ø55 mm) Electronics: 4.8 x 2.76 x 1.18" (122 x 70 x 30 mm) Cable length: 9.8 ft (3 m) |
Weight | Sensing head: 21.2 oz (600 g) Electronics: 14.8 oz (420 g) |
Measurment Range | -58 to 1787°F (-50 to 975°C) |
Selectable Focus* *4)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C) |
0.11" at 7.87" (2.75 mm at 200 mm) |
Spectral Range | 8 to 14 µm |
Optical Resolution (90% Energy) | 75:1 |
System Accuracy at Ambient Temperature 73 ±9°F (23 ±5°C) | ±1% or ±1.8°F (±1% or ±1°C)* *1)Whichever is greater and at object temperatures >32°F (0°C), ε = 1 |
Repeatability at Ambient Temperature 73 ±9°F (23 ±5°C) | ±0.5% or ±0.9°F (±0.5% or ±0.5°C)* *2)Whichever is greater and at object temperatures >32°F (0°C), ε = 1 |
Response Time (90% signal)* *5)With dynamic adaption at low signal levels |
120 ms |
Emissivity/Gain | 0.1 to 1.1 |
IR Window Correction | 0.1 to 1 |
Signal Processing | Peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software | optris® Compact Connect |
Inputs | Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) |
Output | Analog: Channel 1: 0/4 to 20 mA, 0 to 5/10 V, thermocouple J, K, Channel 2: sensing head temperature (-40 to 185°F [-40 to 85°C) as 0 to 5 V or 0 to 10 V), alarm output Alarm: 24 V / 50 mA (open collector) Digital: USB, RS232, RS485, CAN, Profibus DP Impedances: mA maximum 500 Ω (with 5 to 36 V DC) mV minimum 100 kΩ load impedance, thermocouple 20 Ω |
Current Draw (Laser) | Maximum 160 mA |
Laser 635 nm | 1 mW, ON/OFF via electronic box or software |
Environmental Rating | IP 65 (NEMA-4) |
Temperature | Ambient*: -4 to 185°F (-20 to 85°C), 122°F (50°C) with laser ON Storage: Sensing head: -4 to 257°F (-40 to 125°C) Electronics: -40 to 185°F (-40 to 85°C) *3)The functioning of the LCD display may be limited in ambient temperatures below 32°F (0°C) |
Relative Humidity | 10 to 95%, non condensing |
Vibration | IEC 68-2-6: 3 G, 11 to 200 Hz, any axis |
Shock | IEC 68-2-27: 50 G, 11 ms, any axis |
Power Supply | 8 to 36 V DC |
Dimensions | Sensing head: 0.39 x ø2.17" (100 x ø55 mm) Electronics: 4.8 x 2.76 x 1.18" (122 x 70 x 30 mm) Cable length: 9.8 ft (3 m) |
Weight | Sensing head: 21.2 oz (600 g) Electronics: 14.8 oz (420 g) |