Ideal for non-metallic surfaces, this two-wire infrared thermometer features a single-piece sensor with electronics in the sensing head and measures a range of -22 to 1832°F (-30 to 1000°C). In addition, this thermometer features CF optics and an optical parameter of 0.16" at 7.87" (4 mm at 200 mm).
Ideal for non-metallic surfaces, this two-wire infrared thermometer features a single-piece sensor with electronics in the sensing head and measures a range of -22 to 1832°F (-30 to 1000°C). In addition, this thermometer features CF optics and an optical parameter of 0.16" at 7.87" (4 mm at 200 mm).
Features
Applications
Temperature Range (Scalable Via Software) | -22 to 1832°F (-30 to 1000°C) |
Spectral Range | 8 to 14 µm |
Optical Resolution (90% Energy) | 50:1 |
CF Optics | 0.16" at 7.87" (4 mm at 200 mm) |
System Accuracy at Ambient Temperature 73 ±9°F (23 ±5°C) | ±1% or 1.8°F (1°C)* *1)Whichever is greater |
Repeatability at Ambient Temperature 73 ±9°F (23 ±5°C) | ±0.5% or 0.9°F (0.5°C) |
Temperature Resolution | 0.1 K |
Response Time (90% Signal) | 150 ms |
Emissivity/Gain (Adjustable Via Sensor or Software) | 0.1 to 1.1 |
IR Window Correction (Adjustable Via Software) | 0.1 to 1 |
Signal Processing (Parameter Adjustable Via Software) | Peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software | optris® Compact Connect |
Output | Analog: 4 to 20 mA Loop resistance: Maximum 1000 Ω* Alarm: 0 to 30 V/500 mA (open collector) Digital: Uni-/bidirectional, 9.6 kBaud, 0/3 V Pegel, USB optional *2)In dependence on supply voltage |
Current Draw (Laser) | 45 mA at 5 V 20 mA at 12 V 12 mA at 24 V |
Environmental Rating | IP 65 (NEMA-4) front mountable at vacuum processes (up to 103 mbar) |
Temperature | Ambient: -4 to 158°F (122°F with laser on), -20 to 70°C (50°C with laser on) Storage: -40 to 185°F (-40 to 85°C) |
Relative Humidity | 10 to 95%, non condensing |
Vibration | IEC 68-2-6: 3 G, 11 to 200 Hz, any axis |
Shock | IEC 68-2-27: 50 G, 11 ms, any axis |
Power Supply | 5 to 30 V DC |
Dimensions | 0.39 x ø2.17" (100 x ø55 mm) Cable length: 9.8' (3 m) |
Weight | 21.2 oz (600 g) |
Temperature Range (Scalable Via Software) | -22 to 1832°F (-30 to 1000°C) |
Spectral Range | 8 to 14 µm |
Optical Resolution (90% Energy) | 50:1 |
CF Optics | 0.16" at 7.87" (4 mm at 200 mm) |
System Accuracy at Ambient Temperature 73 ±9°F (23 ±5°C) | ±1% or 1.8°F (1°C)* *1)Whichever is greater |
Repeatability at Ambient Temperature 73 ±9°F (23 ±5°C) | ±0.5% or 0.9°F (0.5°C) |
Temperature Resolution | 0.1 K |
Response Time (90% Signal) | 150 ms |
Emissivity/Gain (Adjustable Via Sensor or Software) | 0.1 to 1.1 |
IR Window Correction (Adjustable Via Software) | 0.1 to 1 |
Signal Processing (Parameter Adjustable Via Software) | Peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software | optris® Compact Connect |
Output | Analog: 4 to 20 mA Loop resistance: Maximum 1000 Ω* Alarm: 0 to 30 V/500 mA (open collector) Digital: Uni-/bidirectional, 9.6 kBaud, 0/3 V Pegel, USB optional *2)In dependence on supply voltage |
Current Draw (Laser) | 45 mA at 5 V 20 mA at 12 V 12 mA at 24 V |
Environmental Rating | IP 65 (NEMA-4) front mountable at vacuum processes (up to 103 mbar) |
Temperature | Ambient: -4 to 158°F (122°F with laser on), -20 to 70°C (50°C with laser on) Storage: -40 to 185°F (-40 to 85°C) |
Relative Humidity | 10 to 95%, non condensing |
Vibration | IEC 68-2-6: 3 G, 11 to 200 Hz, any axis |
Shock | IEC 68-2-27: 50 G, 11 ms, any axis |
Power Supply | 5 to 30 V DC |
Dimensions | 0.39 x ø2.17" (100 x ø55 mm) Cable length: 9.8' (3 m) |
Weight | 21.2 oz (600 g) |