Onset HOBO KIT-D-U20-01 Water Level Data Logger Deluxe Kit, 30'

Model: KIT-D-U20-01

Onset HOBO KIT-D-U20-01 Water Level Data Logger Deluxe Kit, 30'

Model: KIT-D-U20-01

Ideal for monitoring water levels, fully compensated for barometric pressure, temperature, and water density; in wells, streams, lakes and freshwater wetlands.

Ideal for monitoring water levels, fully compensated for barometric pressure, temperature, and water density; in wells, streams, lakes and freshwater wetlands.

Your Price $1560.00 USD
Availability 2 to 3 Weeks
Quantity

Onset HOBO KIT-D-U20-01 Offers

Features

  • Lightning protection - no long signal wires, and electronics are shielded in stainless steel housing (see the Water Level logger sensor location drawing)
  • HOBOware Pro software provides easy conversion to accurate water level reading, fully compensated for barometric pressure (see demo) temperature, and water density
  • Multiple-rate sampling (see demo) allows faster sampling at critical times such as when pumping starts or stops
  • Ideal for use in wells, streams, lakes, wetlands and tidal areas
  • No-vent-tube design for easy reliable deployment
  • Durable ceramic pressure sensor

Applications

  • Water Quality Monitoring
  • Coastal Ecology
  • Hydrology Studies
  • Agricultural Research

Onset HOBO KIT-D-U20-01 Specifications

Pressure Sensor
Operation Range 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
Factory Calibrated Range 69 to 207 kPa (10 to 30 psia), 0 to 40°C (32 to 104°F)
Burst Pressure 310 kPa (45 psia) or 18 m (60 ft) depth
Water Level Accuracy Typical Error - 0.05% FS, 0.5 cm (0.015 ft) water
Maximum Error - 0.1% FS, 1.0 cm (0.03 ft) water
Raw Pressure Accuracy 0.3% FS, 0.62 kPa (0.09 psi) maximum error
Resolution <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
Pressure Response Time 90% < 1 second
Temperature Sensor
Operation Range -20 to 50°C (-4 to 122°F)
Accuracy 0.37°C at 20°C (0.67°F at 68°F), See Plot A
Resolution 0.1°C at 20°C (0.18°F at 68°F) (10-bit)
Response Time (90%) 3.5 Minutes in water (typical)
Stability (Drift) 0.1°C (0.18°F) Per Year
Logger
Real-Time Clock ± 1 Minute per month 0 to 50°C (32 to 122°F)
Battery 2/3 AA, 3.6 Volt Lithium, Factory-Replaceable
Battery life (Typical Use) 5 Years with 1 minute or greater logging interval
Memory (Non-Volatile) 64K Bytes Memory (Approx. 21,700 Pressure and Temperature Samples)
Dimensions 2.46 cm (0.97") Diameter, 15 cm (5.9") Length; Mounting Hole 6.3 mm (0.25") Diameter
Weight Approximately 210 g (7.4 oz)
Wetted Materials 316 Stainless Steel, Viton O-Rings, Acetyl Cap, Ceramic Sensor
Shock/Drop Logger is sensitive to shocks. Handle with care and avoid any impact. Always use proper packaging when shipping the logger.
Logging Interval Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours. Refer to HOBOware software manual.
Launch Modes Immediate Start and Delayed Start
Offload Modes Offload While Logging; Stop and Offload
Battery Indication Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile.

What's included with the Onset HOBO KIT-D-U20-01

  • U20-001-01 HOBO Data Logger (30' Range)
  • U20-001-04 HOBO Data Logger (13' Range) for Barometric Pressure
  • U-DTW-1 HOBO Waterproof Shuttle with Coupler
  • U20-CASE-1 Carrying Case
  • BHW-PRO-CD HOBOware Pro Software

Click on a category to view a selection of compatible accessories with the Onset HOBO KIT-D-U20-01 Water Level Data Logger Deluxe Kit, 30'.

Onset HOBO CABLE-1-50 Stainless Steel Cable, 50' CABLE-1-50
A 50-foot length of 1/16-inch diameter teflon-coated stainless steel cable, coiled and bound.




Onset HOBO CABLE-1-300 Stainless Steel Cable, 300' CABLE-1-300
A 300-foot length of 1/16-inch diameter teflon-coated stainless steel cable, coiled and bound.




Onset HOBO CABLE-1-CRIMP Crimp Sleeve for CABLE-1-XX, 12-pack CABLE-1-CRIMP
An envelope of twelve 3/8-inch long stainless steel crimp sleeves for use with 1/16" teflon-coated stainless steel cable.




Onset HOBO HOUSING-U2X Protective Mounting Enclosure HOUSING-U2X
A protective enclosure for mounting U24 conductivity and U20 water level data loggers. The U2X housing is designed to allow a data logger to be mounted in harsh environments while not restricting the flow of media around the device.




Ask a question about Onset HOBO KIT-D-U20-01 Water Level Data Logger Deluxe Kit, 30'

Customer Reviews for the Onset HOBO KIT-D-U20-01

Onset HOBO KIT-D-U20-01 Offers

Features

  • Lightning protection - no long signal wires, and electronics are shielded in stainless steel housing (see the Water Level logger sensor location drawing)
  • HOBOware Pro software provides easy conversion to accurate water level reading, fully compensated for barometric pressure (see demo) temperature, and water density
  • Multiple-rate sampling (see demo) allows faster sampling at critical times such as when pumping starts or stops
  • Ideal for use in wells, streams, lakes, wetlands and tidal areas
  • No-vent-tube design for easy reliable deployment
  • Durable ceramic pressure sensor

Applications

  • Water Quality Monitoring
  • Coastal Ecology
  • Hydrology Studies
  • Agricultural Research

Onset HOBO KIT-D-U20-01 Specifications

Pressure Sensor
Operation Range 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
Factory Calibrated Range 69 to 207 kPa (10 to 30 psia), 0 to 40°C (32 to 104°F)
Burst Pressure 310 kPa (45 psia) or 18 m (60 ft) depth
Water Level Accuracy Typical Error - 0.05% FS, 0.5 cm (0.015 ft) water
Maximum Error - 0.1% FS, 1.0 cm (0.03 ft) water
Raw Pressure Accuracy 0.3% FS, 0.62 kPa (0.09 psi) maximum error
Resolution <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
Pressure Response Time 90% < 1 second
Temperature Sensor
Operation Range -20 to 50°C (-4 to 122°F)
Accuracy 0.37°C at 20°C (0.67°F at 68°F), See Plot A
Resolution 0.1°C at 20°C (0.18°F at 68°F) (10-bit)
Response Time (90%) 3.5 Minutes in water (typical)
Stability (Drift) 0.1°C (0.18°F) Per Year
Logger
Real-Time Clock ± 1 Minute per month 0 to 50°C (32 to 122°F)
Battery 2/3 AA, 3.6 Volt Lithium, Factory-Replaceable
Battery life (Typical Use) 5 Years with 1 minute or greater logging interval
Memory (Non-Volatile) 64K Bytes Memory (Approx. 21,700 Pressure and Temperature Samples)
Dimensions 2.46 cm (0.97") Diameter, 15 cm (5.9") Length; Mounting Hole 6.3 mm (0.25") Diameter
Weight Approximately 210 g (7.4 oz)
Wetted Materials 316 Stainless Steel, Viton O-Rings, Acetyl Cap, Ceramic Sensor
Shock/Drop Logger is sensitive to shocks. Handle with care and avoid any impact. Always use proper packaging when shipping the logger.
Logging Interval Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours. Refer to HOBOware software manual.
Launch Modes Immediate Start and Delayed Start
Offload Modes Offload While Logging; Stop and Offload
Battery Indication Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile.

What's included with the Onset HOBO KIT-D-U20-01

  • U20-001-01 HOBO Data Logger (30' Range)
  • U20-001-04 HOBO Data Logger (13' Range) for Barometric Pressure
  • U-DTW-1 HOBO Waterproof Shuttle with Coupler
  • U20-CASE-1 Carrying Case
  • BHW-PRO-CD HOBOware Pro Software

Click on a category to view a selection of compatible accessories with the Onset HOBO KIT-D-U20-01 Water Level Data Logger Deluxe Kit, 30'.

Onset HOBO CABLE-1-50 Stainless Steel Cable, 50' CABLE-1-50
A 50-foot length of 1/16-inch diameter teflon-coated stainless steel cable, coiled and bound.




Onset HOBO CABLE-1-300 Stainless Steel Cable, 300' CABLE-1-300
A 300-foot length of 1/16-inch diameter teflon-coated stainless steel cable, coiled and bound.




Onset HOBO CABLE-1-CRIMP Crimp Sleeve for CABLE-1-XX, 12-pack CABLE-1-CRIMP
An envelope of twelve 3/8-inch long stainless steel crimp sleeves for use with 1/16" teflon-coated stainless steel cable.




Onset HOBO HOUSING-U2X Protective Mounting Enclosure HOUSING-U2X
A protective enclosure for mounting U24 conductivity and U20 water level data loggers. The U2X housing is designed to allow a data logger to be mounted in harsh environments while not restricting the flow of media around the device.




Ask a question about Onset HOBO KIT-D-U20-01 Water Level Data Logger Deluxe Kit, 30'

Customer Reviews for the Onset HOBO KIT-D-U20-01

More Onset HOBO Products

Calibration Lab