OAKTON PH 560 Alpha pH/ORP Controller

Model: PH 560 | Order No: WD-56717-32

OAKTON PH 560 Alpha pH/ORP Controller

Model: PH 560 | Order No: WD-56717-32

An economical way to measure pH and temperature values. The controller can be used for applications such as water treatment and monitoring, galvanic-decontamination, chemical processing, food processing, clean or wastewater control and neutralization processes.

An economical way to measure pH and temperature values. The controller can be used for applications such as water treatment and monitoring, galvanic-decontamination, chemical processing, food processing, clean or wastewater control and neutralization processes.

Sale Price $454.74 USD
Regular Price $572.00 USD
Availability 5 Days
Quantity

OAKTON PH 560 Offers

Features

  • Push-button keypad for calibration and setup
  • Built-in non-volatile memory to ensure that calibration and other information are not erased if power supply fails
  • Menu-driven program that simplifies setup
  • 1 or 2 point calibration with selectable USA or NIST standard pH buffer set
  • Automatic temperature compensation (ATC)
  • Manual temperature compensation setting without the ATC probe, with independent setting for calibration and process temperature
  • High resolution ADC for precise measurement
  • Large dual display LCD for easy reading with clear multiple annunciators, operational mode indicators and error indicators
  • Two switching contacts as set-point relays
  • Limit (on/off) control mode
  • Separately adjustable high and low set-point hysteresis (dead bands) to prevent chattering of relays around the set points
  • 0 to 2000 seconds time delay adjustment on all relays – minimizes false alarms
  • Backlight LCD display

Applications

  • Laboratory
  • Water Treatment and Controlling
  • Galvanic-Decontamination
  • Chemical Processing
  • Food Processing
  • Clean or Wastewater Control
  • Neutralization Processes

OAKTON PH 560 Specifications

pH
Measuring Range 0.00 to 14.00 pH
Resolution 0.01 pH
Accuracy ±0.01 pH
mV
Measuring Range -1000 to 1000 mV
Resolution 1 mV
Accuracy ±1 mV
Temperature
Measuring Range -10.0 to 125.0°C (14.0 to 257°F)
Resolution 0.1°C (0.1°F)
Resolution is 0.1°F up to 199.9°F and 1°F for 200°F and above
Relative Accuracy ±0.5°C (±1.0°F)
Compensation Automatic or Manual

What's included with the OAKTON PH 560

  • PH 560 Alpha pH Controller
  • 110 VAC to 9 VDC Power Adapter

Click on a category to view a selection of compatible accessories with the OAKTON PH 560 Alpha pH/ORP Controller.

OAKTON WD-35634-47 Replacement ORP 50 Sensor WD-35634-47
For use with the ORPTestr 50.




OAKTON WD-35801-21 In-Line Submersible ORP Electrode with Bulb Guard, DJSC WD-35801-21
Submersible electrodes are permanently encapsulated in a 3ft pipe making it perfect for tank installations. The ABS plastic body can withstand temperatures of up to 80°C.




OAKTON WD-35805-27 ORP Electrode, Gold Disk, DJSE WD-35805-27
For use with any meter that has a BNC connector.




Ask a question about OAKTON PH 560 Alpha pH/ORP Controller

Customer Reviews for the OAKTON PH 560

OAKTON PH 560 Offers

Features

  • Push-button keypad for calibration and setup
  • Built-in non-volatile memory to ensure that calibration and other information are not erased if power supply fails
  • Menu-driven program that simplifies setup
  • 1 or 2 point calibration with selectable USA or NIST standard pH buffer set
  • Automatic temperature compensation (ATC)
  • Manual temperature compensation setting without the ATC probe, with independent setting for calibration and process temperature
  • High resolution ADC for precise measurement
  • Large dual display LCD for easy reading with clear multiple annunciators, operational mode indicators and error indicators
  • Two switching contacts as set-point relays
  • Limit (on/off) control mode
  • Separately adjustable high and low set-point hysteresis (dead bands) to prevent chattering of relays around the set points
  • 0 to 2000 seconds time delay adjustment on all relays – minimizes false alarms
  • Backlight LCD display

Applications

  • Laboratory
  • Water Treatment and Controlling
  • Galvanic-Decontamination
  • Chemical Processing
  • Food Processing
  • Clean or Wastewater Control
  • Neutralization Processes

OAKTON PH 560 Specifications

pH
Measuring Range 0.00 to 14.00 pH
Resolution 0.01 pH
Accuracy ±0.01 pH
mV
Measuring Range -1000 to 1000 mV
Resolution 1 mV
Accuracy ±1 mV
Temperature
Measuring Range -10.0 to 125.0°C (14.0 to 257°F)
Resolution 0.1°C (0.1°F)
Resolution is 0.1°F up to 199.9°F and 1°F for 200°F and above
Relative Accuracy ±0.5°C (±1.0°F)
Compensation Automatic or Manual

What's included with the OAKTON PH 560

  • PH 560 Alpha pH Controller
  • 110 VAC to 9 VDC Power Adapter

Click on a category to view a selection of compatible accessories with the OAKTON PH 560 Alpha pH/ORP Controller.

OAKTON WD-35634-47 Replacement ORP 50 Sensor WD-35634-47
For use with the ORPTestr 50.




OAKTON WD-35801-21 In-Line Submersible ORP Electrode with Bulb Guard, DJSC WD-35801-21
Submersible electrodes are permanently encapsulated in a 3ft pipe making it perfect for tank installations. The ABS plastic body can withstand temperatures of up to 80°C.




OAKTON WD-35805-27 ORP Electrode, Gold Disk, DJSE WD-35805-27
For use with any meter that has a BNC connector.




Ask a question about OAKTON PH 560 Alpha pH/ORP Controller

Customer Reviews for the OAKTON PH 560

More OAKTON Products

Calibration Lab