Ideal for emission monitoring of combustion and industrial processes, this analyzer set measures oxygen, carbon monoxide, differential pressure, and temperature and calculates carbon dioxide based on other measurements. In addition, this kit includes a probe with a sampling line, a probe tube, and a carrying case.
Ideal for emission monitoring of combustion and industrial processes, this analyzer set measures oxygen, carbon monoxide, differential pressure, and temperature and calculates carbon dioxide based on other measurements. In addition, this kit includes a probe with a sampling line, a probe tube, and a carrying case.
Cost-effective and user-friendly, this combustion/emission analyzer features a high-resolution display for providing more information with detailed graphics. Additionally, this analyzer features an illuminated condensate trap and water-stop and WLAN network connectivity.
Features
Applications
Oxygen (Long Life) | Measuring range: 0 to 21% Resolution: 0.1% Accuracy: ±0.2 volume % abs |
Carbon Monoxide (H2 Compensated) | Measuring range: 0 to 10,000/20,000 ppm Resolution: 1 ppm Accuracy: ±10 ppm or 5% reading <4000 ppm, 10% reading >4000 ppm |
Temperature | Stack: Measuring range: 32 to 1472°F (0 to 800°C) with stainless steel Resolution: 1°F (-17.22°C) Accuracy: ±4 to <392°F (-15.55 to <200°C), 1% reading >392°F (200°C) Flue gas: Measuring range: 32 to 2012°F (0 to 1100°C) with inconel Resolution: 1°F (-17.22°C) Accuracy: ±4 to <392°F (-15.55 to <200°C), 1% reading >392°F (200°C) Primary/ambient air: Measuring range: 32 to 212°F (0 to 100°C) Resolution: 1°F (-17.22°C) Accuracy: ± 2°F (-16.66°C) Differential: Measuring range: Up to 2012°F (0 to 1100°C) Resolution: 1°F (-17.22°C) Accuracy: ±4 to <392°F (-15.55 to <200°C), 1% reading >392°F (200°C) |
Stack Draft | Measuring range: ±40 in H2O (100 hPa) Resolution: 1 Pa Accuracy: ±0.02 in H2O or 1% reading |
Differential Pressure | Measuring range: ±80 in H2O (200 hPa) Resolution: 1 Pa Accuracy: ±0.02 in H2O or 1% reading |
Gas Flow Velocity Measurement | Measuring range: 3 to 100 m/s (using pitot tube) Resolution: 0.1 m/s |
Calculated Values | Carbon dioxide: 0 to CO2 maximum Efficiency: 0 to 120% Excess air: 0 to 99.9 Heat losses qA: 0 to 99.9% Air ratio (lambda): 1 to 9.99 CO/CO2 ratio: 0 to 10 |
Maximum Suction Range Gas Pump/Typical Gas Flow | 150 hPa/50 l/h |
Internal Memory | 32,000 data sets |
Data Transmission/Interfaces | USB, Bluetooth, WLAN/USB, Bluetooth, WLAN, IRDA, SD card |
Display | 4" (10.16 cm) color display |
Ambient Conditions | 95% relative humidity, non-condensing |
Protection Class | IP30 |
Probe | Industrial probe with 9' (2.74 m) sampling line and 12" (30.48 cm) exchangeable probe tube |
Power | Internal battery pack: Li-Ion, 20 hours operation time Grid power supply: 100 to 240 V, 5 V DC, 1200 mA |
Dimensions | 4.3 x 8.8 x 2.04" (244 x 113 x 54 mm) |
Weight | 1.65 lbs (750 g) |
Click on a category to view a selection of compatible accessories with the MRU Ampro Plus Analyzer Kit, O2/CO.
Oxygen (Long Life) | Measuring range: 0 to 21% Resolution: 0.1% Accuracy: ±0.2 volume % abs |
Carbon Monoxide (H2 Compensated) | Measuring range: 0 to 10,000/20,000 ppm Resolution: 1 ppm Accuracy: ±10 ppm or 5% reading <4000 ppm, 10% reading >4000 ppm |
Temperature | Stack: Measuring range: 32 to 1472°F (0 to 800°C) with stainless steel Resolution: 1°F (-17.22°C) Accuracy: ±4 to <392°F (-15.55 to <200°C), 1% reading >392°F (200°C) Flue gas: Measuring range: 32 to 2012°F (0 to 1100°C) with inconel Resolution: 1°F (-17.22°C) Accuracy: ±4 to <392°F (-15.55 to <200°C), 1% reading >392°F (200°C) Primary/ambient air: Measuring range: 32 to 212°F (0 to 100°C) Resolution: 1°F (-17.22°C) Accuracy: ± 2°F (-16.66°C) Differential: Measuring range: Up to 2012°F (0 to 1100°C) Resolution: 1°F (-17.22°C) Accuracy: ±4 to <392°F (-15.55 to <200°C), 1% reading >392°F (200°C) |
Stack Draft | Measuring range: ±40 in H2O (100 hPa) Resolution: 1 Pa Accuracy: ±0.02 in H2O or 1% reading |
Differential Pressure | Measuring range: ±80 in H2O (200 hPa) Resolution: 1 Pa Accuracy: ±0.02 in H2O or 1% reading |
Gas Flow Velocity Measurement | Measuring range: 3 to 100 m/s (using pitot tube) Resolution: 0.1 m/s |
Calculated Values | Carbon dioxide: 0 to CO2 maximum Efficiency: 0 to 120% Excess air: 0 to 99.9 Heat losses qA: 0 to 99.9% Air ratio (lambda): 1 to 9.99 CO/CO2 ratio: 0 to 10 |
Maximum Suction Range Gas Pump/Typical Gas Flow | 150 hPa/50 l/h |
Internal Memory | 32,000 data sets |
Data Transmission/Interfaces | USB, Bluetooth, WLAN/USB, Bluetooth, WLAN, IRDA, SD card |
Display | 4" (10.16 cm) color display |
Ambient Conditions | 95% relative humidity, non-condensing |
Protection Class | IP30 |
Probe | Industrial probe with 9' (2.74 m) sampling line and 12" (30.48 cm) exchangeable probe tube |
Power | Internal battery pack: Li-Ion, 20 hours operation time Grid power supply: 100 to 240 V, 5 V DC, 1200 mA |
Dimensions | 4.3 x 8.8 x 2.04" (244 x 113 x 54 mm) |
Weight | 1.65 lbs (750 g) |
Click on a category to view a selection of compatible accessories with the MRU Ampro Plus Analyzer Kit, O2/CO.