Get on-site and real-time oxygen and COe analysis with this high-temperature monitor and continuous combustion optimization at industrial boilers. In addition, this monitor features a ceramic tube and ejector, which is ideal for applications with high temperatures up to approximately 3092°F (1700°C).
Get on-site and real-time oxygen and COe analysis with this high-temperature monitor and continuous combustion optimization at industrial boilers. In addition, this monitor features a ceramic tube and ejector, which is ideal for applications with high temperatures up to approximately 3092°F (1700°C).
Make the combustion process more cost-effective, and get the data to show your organization cares about the environment with this in-situ O2 and COe monitor.
Features
Applications
Oxygen (O2) | Measuring range: 0 to 25 volume % absolute Resolution: 0.01% Accuracy: ±0.2% or ±5% of reading* *Whichever is larger |
Combustibles (COe) | Measuring range: 0 to 1000 ppm Resolution: 1 ppm Accuracy: ±50 ppm or ±10% of reading* *Whichever is larger |
Flange | DN65 PN6 flange, Ø6.3" (160 mm) Temperature: 158 to 302°F (70 to 150°C) (condensation moisture must be avoided) |
Probe Tube | 12" to 6.5' (300 mm to 2 m) Ø2.36" (60 mm) |
Response Time/T90 | <10 seconds |
Warm-Up Time | Minimum 30 minutes |
Outputs | Analog: 2x current loop 4 to 20 mA, with galvanic isolation linearized for both 0 to 25% O2 and 0 to 1000 ppm COe (user-definable settings in 0.5% steps are possible) Digital: RS 485 (with Modbus protocol, without galvanic isolation) |
Inlets | Calibration: With test gas fitting for 6/4 mm tube calibration gas supplied manually or automatically via pneumatic unit PU 420 Back-purge: Minimum 6 to 8 bar compressed air with quick connector for 8 mm tube |
Transmitter | Electronics: With local microprocessor, display, and 4 push-buttons Enclosure: Die-cast aluminum |
Ambient Temperature of Electronics | -4 to 140°F (-20 to 60°C) |
Protection Class | IP65 |
Power Supply | 100 to 240 V AC, maximum 100 W |
Dimensions | 6.3 x 6.3 x 2.36" (160 x 160 x 60 mm) and 7.87" (200 mm) probe tube, Ø1.97" (50 mm) |
Weight | Approximately 7.7 lbs (3.5 kg) without probe and flange |
Oxygen (O2) | Measuring range: 0 to 25 volume % absolute Resolution: 0.01% Accuracy: ±0.2% or ±5% of reading* *Whichever is larger |
Combustibles (COe) | Measuring range: 0 to 1000 ppm Resolution: 1 ppm Accuracy: ±50 ppm or ±10% of reading* *Whichever is larger |
Flange | DN65 PN6 flange, Ø6.3" (160 mm) Temperature: 158 to 302°F (70 to 150°C) (condensation moisture must be avoided) |
Probe Tube | 12" to 6.5' (300 mm to 2 m) Ø2.36" (60 mm) |
Response Time/T90 | <10 seconds |
Warm-Up Time | Minimum 30 minutes |
Outputs | Analog: 2x current loop 4 to 20 mA, with galvanic isolation linearized for both 0 to 25% O2 and 0 to 1000 ppm COe (user-definable settings in 0.5% steps are possible) Digital: RS 485 (with Modbus protocol, without galvanic isolation) |
Inlets | Calibration: With test gas fitting for 6/4 mm tube calibration gas supplied manually or automatically via pneumatic unit PU 420 Back-purge: Minimum 6 to 8 bar compressed air with quick connector for 8 mm tube |
Transmitter | Electronics: With local microprocessor, display, and 4 push-buttons Enclosure: Die-cast aluminum |
Ambient Temperature of Electronics | -4 to 140°F (-20 to 60°C) |
Protection Class | IP65 |
Power Supply | 100 to 240 V AC, maximum 100 W |
Dimensions | 6.3 x 6.3 x 2.36" (160 x 160 x 60 mm) and 7.87" (200 mm) probe tube, Ø1.97" (50 mm) |
Weight | Approximately 7.7 lbs (3.5 kg) without probe and flange |