Class-leading charge current, noise rejection, and software filters make this one of the most advanced DC insulation resistance testers to date. In addition, with a 10 kV resistance range and instrument productivity as the primary focus, this tester uses an intuitive user interface to ensure simple and easy operation.
Class-leading charge current, noise rejection, and software filters make this one of the most advanced DC insulation resistance testers to date. In addition, with a 10 kV resistance range and instrument productivity as the primary focus, this tester uses an intuitive user interface to ensure simple and easy operation.
Safety of operation is built in, 5 kV and 10 kV models are safety rated to CAT IV 600 V up to 3000 m, and the 15 kV S1-1568 is rated at CAT IV 1000 V up to 4000 m. Original equipment manufacturers and repairers will welcome the remote control feature allowing them to automate resistance testing on the factory floor, as will technicians in substations wanting to operate from a more convenient, safe distance. The S1-Series has a dual case design with a tough outer case to protect the tester from knocks and drops and a fire-retardant inner case. The case IP rating prevents moisture and dust ingress when storing or carrying the instrument.
The lids have clip-on lead pouches ensuring that leads remain with the instrument at all times. Case lids are removable for improved access to the terminals. Five preset voltage ranges are provided in insulation test mode, plus a user-settable lock voltage range. Preconfigured diagnostic tests include Polarisation Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Stepped Voltage (SV), and Ramp test. Advanced memory storage includes time/date stamping of results, logging of data, and recall of results to screen. A fully isolated USB interface or onboard Bluetooth® interface is used for the safe transfer of data to Megger’s asset management software; PowerDB Pro, Advanced, or Lite packages.
Features
PI Prediction Function (PIp)
The Polarisation Index test can be time consuming, with a 10 minute test (30 minutes on 3 phase) and with multiple items to test, any time saved is a bonus. PIp does just that. The PI predictor function uses the first part of the IR curve to predict the rest at 5 minutes into the test. The PIp can start as early as 3 minutes into the test and will stop when it is confident in the prediction.
Test leads supplied
The S1568, S11068 and the S11568 are all supplied with test leads that are compliant with the requirements of IEC61010-031:2008.
These leads are designed based on Megger's extensive knowledge of insulation testing using the latest technology. The leads are in compliance with IEC61010-31:2008, which requires a fully insulated clip design.
Medium insulated test clip 3 M x 3 leadset – 5 kV and 10 kV
These test leads are supplied as standard on S1568 and the S11068.
Large insulated test clip 3 M X 3 leadset
These test leads are supplied as standard on S11068 and S11568 models (different leadset dependant on model). These clips are designed for clamping on to larger diameter test pieces.
10 kV lead set Cable
15 kV lead set Cable
Designed for everyday use
Test leads are a key component of any precision instrument and safety, long life, and the ability to provide reliable connections to a variety of test pieces found in everyday applications are of the utmost importance. Megger design test leads for both safety and practical operation.
Locking HV insulated plugs/non-removable test clips
All Megger 5 kV, 10 kV and 15 kV insulation testing test leads are fitted with unique locking HV plugs and non-removable test clips.
Practical insulation design
Moving jaw fingers maintain the clips touch-proof safety when the slip is closed, but flex back to allow the metal teeth of the clip to contact test piece unimpeded when in use.
Applications
AC Voltage (Auto Ranging) | 90 to 264 Vrms, 50/60 Hz, 100 A |
Test Voltage | 250 V, 500 V, 1000 V, 2500 V, 5000 V, 10,000 V, 15,000 V, V max |
Lock Test Voltage | 40 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps |
Test Voltage Accuracy | 4%, 0%, 10 V nominal voltage at 1 GO load (32 to 86°F, 0 to 30°C) |
Resistance Range | 10 k to 15 TO at 5 kV, 10 k to 35 TO at 10 kV, 10 k to 35 TO at 15 kV |
Guard Terminal Performance | Guards out parallel leakage resistance down to 250 kΩ with a maximum additional resistance error of 1% with a 100 MΩ load |
Display Range | Analogue: 100 kΩ to 10 TΩ Digital: 10 kΩ to 35 TΩ |
Short Circuit/Charge Current | 6 mA |
Insulation Test Alarm | 100 kΩ to 10 GΩ |
Capacitor Charge (on Battery) | On battery: <2.5 μF to 5 kV <5 μF to 10 kV <6.3 μF to 15 kV With AC: <1.5 μF to 5 kV <2.7 μF to 10 kV <4 μF to 15 kV |
Capacitor Discharge | <250 ms/μF discharge from 10 kV to 50 V |
Capacitance Range | With test voltage set above 500V: 10 nF to 25 μF |
Capacitance Measurement Accuracy | 10 nF to 10 μF: ±10%; ±5 nF |
Current Range | 0.1 nA to 6 mA |
Current Accuracy | ±5% ±0.2 nA at all voltages (68°F, 20°C) |
Interference | 8 mA from 2560 V to 10 kV |
Software 4 Filter Settings | 10, 30, 100, 200 s |
Voltmeter | Range: 30 V to 660 V AC or DC, 45 to 65 Hz Accuracy: ±3%, ±3V |
Timer Range | Up to 99 minutes 59 seconds, 15 second minimum setting |
Memory Capacity | 11 hours logging at 5 sec intervals |
Test Modes | IR, IR(t), DAR, PI, SV, DD, ramp test |
Interface | USB type B (device), Bluetooth® Class 2 |
Maximum Altitude | 3000 m |
Environmental Conditions | Operating temperature: -4 to 122°F (-20 to 50°C) Storage temperature: -13 to 149°F (-25 to 65°C) Humidity: 90% RH non-condensing at 104°F (40°C) |
IP Rating | IP65 (lid closed), IP40 (lid open) |
Safety | Meets the requirements of IEC 61010-1, CATIV 600 V to 3000 m |
EMC | Meets the requirements of IEC61326-1 |
Real Time Output | (V, I, R) readings at a rate of 1 Hz |
Remote Control | Remote control via USB cable only (requires RC dongle to be in position) |
30 Minute Quick Charge | 1 hour operation at 5 kV with a 100 MO load |
Auto Power Off | Instrument turns off after a few minutes if non-use to conserve battery life |
Battery | Charge time: 2.5 hours deep discharge, 2 hours normal discharge Rating: 11.1 V, 5.2 Ah meets IEC 62133: 2003 Lifetime: 4.5 hours (typical) continuous testing at 10 KV with a 100 MO load |
Dimensions | 11.22 x 7.1 x 12.4" (285 x 181 x 315 mm) |
Weight | 9.9 lbs (4.5 kg) |
Click on a category to view a selection of compatible accessories with the Megger S1 Series Insulation Resistance Tester, 10 kV.
AC Voltage (Auto Ranging) | 90 to 264 Vrms, 50/60 Hz, 100 A |
Test Voltage | 250 V, 500 V, 1000 V, 2500 V, 5000 V, 10,000 V, 15,000 V, V max |
Lock Test Voltage | 40 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps |
Test Voltage Accuracy | 4%, 0%, 10 V nominal voltage at 1 GO load (32 to 86°F, 0 to 30°C) |
Resistance Range | 10 k to 15 TO at 5 kV, 10 k to 35 TO at 10 kV, 10 k to 35 TO at 15 kV |
Guard Terminal Performance | Guards out parallel leakage resistance down to 250 kΩ with a maximum additional resistance error of 1% with a 100 MΩ load |
Display Range | Analogue: 100 kΩ to 10 TΩ Digital: 10 kΩ to 35 TΩ |
Short Circuit/Charge Current | 6 mA |
Insulation Test Alarm | 100 kΩ to 10 GΩ |
Capacitor Charge (on Battery) | On battery: <2.5 μF to 5 kV <5 μF to 10 kV <6.3 μF to 15 kV With AC: <1.5 μF to 5 kV <2.7 μF to 10 kV <4 μF to 15 kV |
Capacitor Discharge | <250 ms/μF discharge from 10 kV to 50 V |
Capacitance Range | With test voltage set above 500V: 10 nF to 25 μF |
Capacitance Measurement Accuracy | 10 nF to 10 μF: ±10%; ±5 nF |
Current Range | 0.1 nA to 6 mA |
Current Accuracy | ±5% ±0.2 nA at all voltages (68°F, 20°C) |
Interference | 8 mA from 2560 V to 10 kV |
Software 4 Filter Settings | 10, 30, 100, 200 s |
Voltmeter | Range: 30 V to 660 V AC or DC, 45 to 65 Hz Accuracy: ±3%, ±3V |
Timer Range | Up to 99 minutes 59 seconds, 15 second minimum setting |
Memory Capacity | 11 hours logging at 5 sec intervals |
Test Modes | IR, IR(t), DAR, PI, SV, DD, ramp test |
Interface | USB type B (device), Bluetooth® Class 2 |
Maximum Altitude | 3000 m |
Environmental Conditions | Operating temperature: -4 to 122°F (-20 to 50°C) Storage temperature: -13 to 149°F (-25 to 65°C) Humidity: 90% RH non-condensing at 104°F (40°C) |
IP Rating | IP65 (lid closed), IP40 (lid open) |
Safety | Meets the requirements of IEC 61010-1, CATIV 600 V to 3000 m |
EMC | Meets the requirements of IEC61326-1 |
Real Time Output | (V, I, R) readings at a rate of 1 Hz |
Remote Control | Remote control via USB cable only (requires RC dongle to be in position) |
30 Minute Quick Charge | 1 hour operation at 5 kV with a 100 MO load |
Auto Power Off | Instrument turns off after a few minutes if non-use to conserve battery life |
Battery | Charge time: 2.5 hours deep discharge, 2 hours normal discharge Rating: 11.1 V, 5.2 Ah meets IEC 62133: 2003 Lifetime: 4.5 hours (typical) continuous testing at 10 KV with a 100 MO load |
Dimensions | 11.22 x 7.1 x 12.4" (285 x 181 x 315 mm) |
Weight | 9.9 lbs (4.5 kg) |