Megger MIT400 Series 1000V Insulation Testers

Megger MIT400 Series 1000V Insulation Testers

Model Selection

Megger MIT415/2 500V Insulation Tester
MIT415/2 $1,110.00 USD Availability:
11 to 12 Weeks

Model Selection

Analog/Digital Insulation Tester - 250V/500V/1000V insulation + 600V Cat IV.

Analog/Digital Insulation Tester - 250V/500V/1000V insulation + 600V Cat IV.

Megger MIT415/2 500V Insulation Tester
MIT415/2 $1,110.00 USD Availability:
11 to 12 Weeks

Megger MIT400 Insulation Resistance and Continuity Tester

The Megger MIT400 Series insulation and continuity testers has been designed for electrical testing by power utilities, industrials, telecommunication companies, commercial/domestic electricians and anyone with unique test voltage requirements. The wide range of features also makes the MIT400 Series ideal for maintenance technicians and engineers.

They replace the well-established BM400 insulation tester range, giving greater functionality with simplified operation, greater application range and increased safety.


Insulation Voltage Range

MIT400 - 250 V, 500 V and 1000 V


Applications

Industrial and Power Electrical Installation Testing

These models include all the features required for electricians, technicians and engineers working in a range of industries. Available features are selected to make testing easy and fast in a range of situations. Typical applications include:

  • Building/Campus electrical maintenance
  • Large and small scale electrical installations
  • Periodic electrical systems inspection and testing
  • Cable testing

What's Included

  • Set of silicone test leads - Flexible and long lasting, these leads prevent errors from test lead leakage on high resistance type of insulation testing. They also provide increased accuracy above 10 GΩ.
  • Rugged instrument rubber boot with built-in stand- Protects the instrument from dings and drops and provides an easier, better grip of the instrument.
  • High-impact polypropylene carry case - Further protects the instrument and provides space for the leads, switch probe, etc.
  • Owner information CD.
  • Three year product warranty.
  • Free calibration certificate

Instrument Safety

The MIT400 Series instruments are designed to meet all of the requirements of IEC1010-2 and EN61557 and meets the safety requirements for use on CAT IV 600 V.

  • Any live circuit detection inhibits any insulation testing on circuits above 50 V (75 volts on Telecom models)
  • Any live circuit detection and test inhibit on continuity measurements
  • Default display of live circuit voltage on all ranges
  • Detection and inhibit features function even if the protections fuse has failed

Also, fast detection circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases.

Key Features

  • CAT IV 600 V rating - provides greater safety when testing at higher voltage levels
  • Adjustable insulation test voltages - provides 250 V to 1000 V or 50 V to 1000 V.
  • Dual digital display readout - allows display of complimentary test information simultaneously (for example: MΩ plus test voltage or MΩ plus leakage current)
  • Digital and analog arc display - includes not only the digital readout but also Megger's patented analog arc to replicate the response of a moving coil display
  • Exceptional measurement range from 20 GΩ to 200 GΩ - highest insulation test range available on the market, providing a superior range of measurement applications.
  • Choice of 20 mA or 200 mA continuity testing - allows user to select lower continuity range thus increasing battery life considerably
  • Continuity auto-test capability - enables real two-handed operation without the need to press the test button
  • Adjustable continuity limit alarm - allows pass/fail limits to be sent to speed testing
  • Automatically perform PI and DAR tests - user is able to quickly perform two important diagnostic tests. . . Polarization Index (PI) and Dielectric Absorption Ratio (DAR)
  • True RMS voltage measurement - allows accurate voltage measurement on noisy lines
  • Auto ranging voltage measurement - automatically adjusts range from millivolts to 600 V AC or DC, eliminating the need to keep changing ranging
  • Live circuit warning - automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited
  • Auto fuse warning - warns of fuse failure automatically. No need to test the fuse manually.
  • Buzzer select button - enable or disable buzzer as required with resistance also displayed on the screen.
  • Stylish tapered design and center button placement - easy to use with either hand

Specifications (MIT400-EN)

*All quoted accuracies are at +20° C.
Insulation Nominal test voltages 250 V, 500 V, 1000 V
Insulation resistance range 20 GΩ
Range Full Scale Accuracy 1000 volts ±3% ±2 digits ±0.2% per GΩ 500 volts ±3% ±2 digits ±0.4% per GΩ 250 volts ±3% ±2 digits ±0.8% per GΩ
Analog range 1 GΩ full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on load 1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max.
EN61557 Operating range 0.10 M½ to 1.00 GΩ
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Polarization Index (PI) 10 min/1 minute ratio
Dielectric Absorption Ratio (DAR) 60 sec/30 sec ratio
Notes (1) All ranges measure from 0.00 M½ upwards. (2) Above specifications only apply when high quality silicone leadsare being used.
Continuity
Measurement 0.01 ½ to 99.9 ½ (0 to 100 ½ on analog scale)
Accuracy ±3% ±2 digits (0 to 100 Ω)
Open circuit voltage 5 V ±1 V
Test current 200 mA (–0 mA +20 mA) (0.01 ½ to 9.99 Ω) 20mA (±1 mA ) (10.0 ½ to 99.9 Ω)
Zero offset at probe tips 0.10Ω typical
Lead resistance zeroing Up to 9.00 Ω
Buzzer Variable limit 1Ω, 2Ω, 5Ω,10Ω, 20Ω
Resistance
Measurement 0.01 kΩ to 1000 kΩ (0 to 1 MΩ on analog scale)
Accuracy ±3% ±2 digits Open circuit voltage 5 V ±1 V Short circuit current 20 µA ± 5 µA
Voltage range 0 to 600 V d.c. ±2% ±2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits 0 to 1000 V on Analog scale Unspecified input level 0 - 10 mV (40 to 400 Hz) For non-sinusoidal waveforms additional specification apply: ±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter Operates at >25 V a.c. or d.c. on any range except OFF
Frequency 40 - 450 Hz (40 Hz - 99.9 Hz) ±0.5% ±1 digit (100 Hz to450 Hz)
Result storage
Capacity >1000 test results
Download Bluetooth wireless
Bluetooth Class Class II
Range up to 10 m
Power
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Dimensions
Instrument 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument and case 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Instrument and case 1.75kg (3.86 lb)
Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C. In accordance with IEC 61326 including amendment No.1
Temperature effects
Temperature coefficient <0.1&Omega per °C up to 1 G&Omega
Environmental
Operating range -10 to +55° C
Operating humidity 90% RH at 40° C max.
Storage temperature range -25 to +70° C
Calibration Temperature +20° C
Maximum altitude 2000 m
Dust and water protection IP54 Protected against dust and splashing water

What's included with the Megger MIT400-EN

  • Megger MIT400 Series 1000V Insulation Testers
Industrial and Power Applications Telecommunications Applications Special
Insulation Voltage range MIT400 MIT410 MIT420 MIT430 MIT480 MIT481 MIT485 MIT40X
10-100 V variable (2 GΩ - 20 GΩ)
50 V
100 V
250 V
500 V
1000 V
Insulation range 20 GΩ 100 GΩ 200 GΩ 200 GΩ 100 GΩ 200 GΩ 200 GΩ 2-20 GΩ
Leakage current display
INS test voltage display
Continuity Measurement
0.01 to 100 Ω
Variable current limit. 200 mA/20 mA
Fast buzzer- selectable threshold
k Ω range to 999 k Ω
Other functions and features
Live circuit warning at 50 V
Live circuit warning at 75 V
Default voltmeter
TRMS measurement to 600 V
Frequency Hz - 40 to 400 Hz
Capacitance (0.1 nf to 10 µF)
mV/transducer (0.1 to 19.99 V)
Backlight
Battery condition display
Insulation Timed - PI - DAR Tests
Test button plus lock button
Limit alarm pass band on INS
Auto power down
Result storage
Bluetooth downloading
Included Accessories
Red/black silicone lead set with clips
Protective rubber boot with built-in stand
Remote switch probe
Calibration certificate with product
Batteries
3 Year Warranty

Click on a category to view a selection of compatible accessories with the Megger MIT400 Series 1000V Insulation Testers.

Megger 1014-293 Replacement Lead Set for MIT200/300/400 Series 1014-293
Replacement Test Lead Set (Red, Black) with Crocodile Clips for Series MIT200, MIT300 and MIT400.




Ask a question about Megger MIT400 Series 1000V Insulation Testers

Customer Reviews for the Megger MIT400-EN

Megger MIT400 Insulation Resistance and Continuity Tester

The Megger MIT400 Series insulation and continuity testers has been designed for electrical testing by power utilities, industrials, telecommunication companies, commercial/domestic electricians and anyone with unique test voltage requirements. The wide range of features also makes the MIT400 Series ideal for maintenance technicians and engineers.

They replace the well-established BM400 insulation tester range, giving greater functionality with simplified operation, greater application range and increased safety.


Insulation Voltage Range

MIT400 - 250 V, 500 V and 1000 V


Applications

Industrial and Power Electrical Installation Testing

These models include all the features required for electricians, technicians and engineers working in a range of industries. Available features are selected to make testing easy and fast in a range of situations. Typical applications include:

  • Building/Campus electrical maintenance
  • Large and small scale electrical installations
  • Periodic electrical systems inspection and testing
  • Cable testing

What's Included

  • Set of silicone test leads - Flexible and long lasting, these leads prevent errors from test lead leakage on high resistance type of insulation testing. They also provide increased accuracy above 10 GΩ.
  • Rugged instrument rubber boot with built-in stand- Protects the instrument from dings and drops and provides an easier, better grip of the instrument.
  • High-impact polypropylene carry case - Further protects the instrument and provides space for the leads, switch probe, etc.
  • Owner information CD.
  • Three year product warranty.
  • Free calibration certificate

Instrument Safety

The MIT400 Series instruments are designed to meet all of the requirements of IEC1010-2 and EN61557 and meets the safety requirements for use on CAT IV 600 V.

  • Any live circuit detection inhibits any insulation testing on circuits above 50 V (75 volts on Telecom models)
  • Any live circuit detection and test inhibit on continuity measurements
  • Default display of live circuit voltage on all ranges
  • Detection and inhibit features function even if the protections fuse has failed

Also, fast detection circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases.

Key Features

  • CAT IV 600 V rating - provides greater safety when testing at higher voltage levels
  • Adjustable insulation test voltages - provides 250 V to 1000 V or 50 V to 1000 V.
  • Dual digital display readout - allows display of complimentary test information simultaneously (for example: MΩ plus test voltage or MΩ plus leakage current)
  • Digital and analog arc display - includes not only the digital readout but also Megger's patented analog arc to replicate the response of a moving coil display
  • Exceptional measurement range from 20 GΩ to 200 GΩ - highest insulation test range available on the market, providing a superior range of measurement applications.
  • Choice of 20 mA or 200 mA continuity testing - allows user to select lower continuity range thus increasing battery life considerably
  • Continuity auto-test capability - enables real two-handed operation without the need to press the test button
  • Adjustable continuity limit alarm - allows pass/fail limits to be sent to speed testing
  • Automatically perform PI and DAR tests - user is able to quickly perform two important diagnostic tests. . . Polarization Index (PI) and Dielectric Absorption Ratio (DAR)
  • True RMS voltage measurement - allows accurate voltage measurement on noisy lines
  • Auto ranging voltage measurement - automatically adjusts range from millivolts to 600 V AC or DC, eliminating the need to keep changing ranging
  • Live circuit warning - automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited
  • Auto fuse warning - warns of fuse failure automatically. No need to test the fuse manually.
  • Buzzer select button - enable or disable buzzer as required with resistance also displayed on the screen.
  • Stylish tapered design and center button placement - easy to use with either hand

Specifications (MIT400-EN)

*All quoted accuracies are at +20° C.
Insulation Nominal test voltages 250 V, 500 V, 1000 V
Insulation resistance range 20 GΩ
Range Full Scale Accuracy 1000 volts ±3% ±2 digits ±0.2% per GΩ 500 volts ±3% ±2 digits ±0.4% per GΩ 250 volts ±3% ±2 digits ±0.8% per GΩ
Analog range 1 GΩ full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on load 1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max.
EN61557 Operating range 0.10 M½ to 1.00 GΩ
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Polarization Index (PI) 10 min/1 minute ratio
Dielectric Absorption Ratio (DAR) 60 sec/30 sec ratio
Notes (1) All ranges measure from 0.00 M½ upwards. (2) Above specifications only apply when high quality silicone leadsare being used.
Continuity
Measurement 0.01 ½ to 99.9 ½ (0 to 100 ½ on analog scale)
Accuracy ±3% ±2 digits (0 to 100 Ω)
Open circuit voltage 5 V ±1 V
Test current 200 mA (–0 mA +20 mA) (0.01 ½ to 9.99 Ω) 20mA (±1 mA ) (10.0 ½ to 99.9 Ω)
Zero offset at probe tips 0.10Ω typical
Lead resistance zeroing Up to 9.00 Ω
Buzzer Variable limit 1Ω, 2Ω, 5Ω,10Ω, 20Ω
Resistance
Measurement 0.01 kΩ to 1000 kΩ (0 to 1 MΩ on analog scale)
Accuracy ±3% ±2 digits Open circuit voltage 5 V ±1 V Short circuit current 20 µA ± 5 µA
Voltage range 0 to 600 V d.c. ±2% ±2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits 0 to 1000 V on Analog scale Unspecified input level 0 - 10 mV (40 to 400 Hz) For non-sinusoidal waveforms additional specification apply: ±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter Operates at >25 V a.c. or d.c. on any range except OFF
Frequency 40 - 450 Hz (40 Hz - 99.9 Hz) ±0.5% ±1 digit (100 Hz to450 Hz)
Result storage
Capacity >1000 test results
Download Bluetooth wireless
Bluetooth Class Class II
Range up to 10 m
Power
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Dimensions
Instrument 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument and case 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Instrument and case 1.75kg (3.86 lb)
Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C. In accordance with IEC 61326 including amendment No.1
Temperature effects
Temperature coefficient <0.1&Omega per °C up to 1 G&Omega
Environmental
Operating range -10 to +55° C
Operating humidity 90% RH at 40° C max.
Storage temperature range -25 to +70° C
Calibration Temperature +20° C
Maximum altitude 2000 m
Dust and water protection IP54 Protected against dust and splashing water

What's included with the Megger MIT400-EN

  • Megger MIT400 Series 1000V Insulation Testers
Industrial and Power Applications Telecommunications Applications Special
Insulation Voltage range MIT400 MIT410 MIT420 MIT430 MIT480 MIT481 MIT485 MIT40X
10-100 V variable (2 GΩ - 20 GΩ)
50 V
100 V
250 V
500 V
1000 V
Insulation range 20 GΩ 100 GΩ 200 GΩ 200 GΩ 100 GΩ 200 GΩ 200 GΩ 2-20 GΩ
Leakage current display
INS test voltage display
Continuity Measurement
0.01 to 100 Ω
Variable current limit. 200 mA/20 mA
Fast buzzer- selectable threshold
k Ω range to 999 k Ω
Other functions and features
Live circuit warning at 50 V
Live circuit warning at 75 V
Default voltmeter
TRMS measurement to 600 V
Frequency Hz - 40 to 400 Hz
Capacitance (0.1 nf to 10 µF)
mV/transducer (0.1 to 19.99 V)
Backlight
Battery condition display
Insulation Timed - PI - DAR Tests
Test button plus lock button
Limit alarm pass band on INS
Auto power down
Result storage
Bluetooth downloading
Included Accessories
Red/black silicone lead set with clips
Protective rubber boot with built-in stand
Remote switch probe
Calibration certificate with product
Batteries
3 Year Warranty

Click on a category to view a selection of compatible accessories with the Megger MIT400 Series 1000V Insulation Testers.

Megger 1014-293 Replacement Lead Set for MIT200/300/400 Series 1014-293
Replacement Test Lead Set (Red, Black) with Crocodile Clips for Series MIT200, MIT300 and MIT400.




Ask a question about Megger MIT400 Series 1000V Insulation Testers

Customer Reviews for the Megger MIT400-EN

More Megger Products

Calibration Lab