Megger BD-59090 MOM2 Micro-Ohmmeter, Kelvin Probes, 240A

Model: BD-59090-US | Order No: BD-59090

Megger BD-59090 MOM2 Micro-Ohmmeter, Kelvin Probes, 240A

Model: BD-59090-US | Order No: BD-59090

The lightweight, handheld unit made to deliver up to 240 Amps. Performs measurement of resistance of circuit breaker contacts, bus-bar joints, and other high-current links. This product is designed with safety, ease of use and versatility in mind.

The lightweight, handheld unit made to deliver up to 240 Amps. Performs measurement of resistance of circuit breaker contacts, bus-bar joints, and other high-current links. This product is designed with safety, ease of use and versatility in mind.

Regular Price $9915.00 USD
Availability 2 to 3 Weeks
Quantity

Features

  • Delivers up to 240 A to measure resistance of high-current links
  • DualGround technology ensures grounding of test object for safe workflow
  • Auto range from 1 microohm to 1000 milliohms
  • Ultra capacitor technology allows for high current generation
  • Stores up to 190 test results and transfers test data to PC via Bluetooth
  • Supplied with Kelvin clamps for carrying out 4-wire Kelvin test
  • Handheld and portable, weighing only 2.2 lbs (1 kg)
  • Battery powered and rechargeable
  • Complies with IEEE and IEC standards

Applications

  • Circuit breaking testing
  • Testing of bus-bar
  • Switches
  • Disconnecting devices
  • Safety ground connections
  • Welding points
  • Fuses
  • Cables

Both Sides Grounded

Within electrical power utilities, switchgear owners and service companies, there is an increased emphasis on efficiency of operations, maintenance and service levels. There is an increased emphasis on health, safety, and environmental compliance. Experience has also shown demands for shorter time periods for testing, while the switchgear is less and less available to be taken out of service.

Many utilities require safety grounds to remain in place during station outages, therefore, the MOM2 was designed with this field safety constraint in mind. DualGround means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. Minimum time shall be spent in the substation and focus shall be on the test rather than the equipment.

Instrument Front View

  • 1. Current output terminal (-)
  • 2. Current output terminal (+)
  • 3. Display
  • 4. Ground (earth) terminal
  • 5. Keys for navigation and to make settings in the display
  • 6. TEST-button
  • 7. Stand-by/Wake up (Press shortly to toggle)
  • 8. Clear log (Press and hold for 5 seconds)
  • 9. Function selector
  • 10. Connector for the voltage (–) sense lead
  • 11. Connector for the voltage sense (+) lead and the trig function
  • 12. Connector for the battery charger
  • 13. Battery charger indicator

The Kelvin probes (included in BD-59090) are used for a 4-wire Kelvin test. This is a way of measuring continuity resistances ensuring all contact and lead resistances are compensated for, allowing a much greater accuracy in measurements. Each Kelvin probe assembly has two probe tips: one tip is for the current generated; the other will measure the very small voltage present.

The Kelvin clamps (included in BD-59092) use the same principle.

Equipment and methods that supports DualGround™ testing are associated with the DualGround symbol. This symbol certifies the use of groundbreaking technology and methods that enables a safe, fast and easy work?ow with both sides grounded throughout the test.∏∏

Megger BD-59090-US Specifications

Application Field For use in high-voltage substations and industrial environments.
Relative Humidity %RH 5%-95%, non condensing
Pollution Degree 2
Shock IEC 60068-2-27
Vibration Vibration IEC 60068-2-6
Transport ISTA 2A
Battery Power Five AA (HR6) 2700 mAh NiMH cells
Recharge Time < 12 h
Battery Charger Mains Voltage 100 - 250 V AC, 50 / 60 Hz
Power Consumption 60 W
Protection Against wrong battery type, low/high temperature
Real Time Clock Battery Life =10 years
Audible Feedback Different buzzer sounds
User Presets 3
Field Calibration Yes
Encapsulation IP54
Dimensions 217 H x 92 B x 72 D mm
Weight 1.0 kg (2.2 lbs) instrument only
Click here for complete specifications on the Megger BD-59090-US

What's included with the Megger BD-59090-US

  • MOM2 Micro-Ohmmeter
  • 4 ft. (1.3 m) Red Test Cable with Kelvin Clamp
  • 10 ft. (3 m) Black Test Cable with Kelvin Clamp
  • Transport Case
  • Charger
  • Rubber Holster
  • Carrying Strap
  • Belt Clip
  • MOM2 Win Software

Ask a question about Megger BD-59090 MOM2 Micro-Ohmmeter, Kelvin Probes, 240A

Customer Reviews for the Megger BD-59090-US

Features

  • Delivers up to 240 A to measure resistance of high-current links
  • DualGround technology ensures grounding of test object for safe workflow
  • Auto range from 1 microohm to 1000 milliohms
  • Ultra capacitor technology allows for high current generation
  • Stores up to 190 test results and transfers test data to PC via Bluetooth
  • Supplied with Kelvin clamps for carrying out 4-wire Kelvin test
  • Handheld and portable, weighing only 2.2 lbs (1 kg)
  • Battery powered and rechargeable
  • Complies with IEEE and IEC standards

Applications

  • Circuit breaking testing
  • Testing of bus-bar
  • Switches
  • Disconnecting devices
  • Safety ground connections
  • Welding points
  • Fuses
  • Cables

Both Sides Grounded

Within electrical power utilities, switchgear owners and service companies, there is an increased emphasis on efficiency of operations, maintenance and service levels. There is an increased emphasis on health, safety, and environmental compliance. Experience has also shown demands for shorter time periods for testing, while the switchgear is less and less available to be taken out of service.

Many utilities require safety grounds to remain in place during station outages, therefore, the MOM2 was designed with this field safety constraint in mind. DualGround means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. Minimum time shall be spent in the substation and focus shall be on the test rather than the equipment.

Instrument Front View

  • 1. Current output terminal (-)
  • 2. Current output terminal (+)
  • 3. Display
  • 4. Ground (earth) terminal
  • 5. Keys for navigation and to make settings in the display
  • 6. TEST-button
  • 7. Stand-by/Wake up (Press shortly to toggle)
  • 8. Clear log (Press and hold for 5 seconds)
  • 9. Function selector
  • 10. Connector for the voltage (–) sense lead
  • 11. Connector for the voltage sense (+) lead and the trig function
  • 12. Connector for the battery charger
  • 13. Battery charger indicator

The Kelvin probes (included in BD-59090) are used for a 4-wire Kelvin test. This is a way of measuring continuity resistances ensuring all contact and lead resistances are compensated for, allowing a much greater accuracy in measurements. Each Kelvin probe assembly has two probe tips: one tip is for the current generated; the other will measure the very small voltage present.

The Kelvin clamps (included in BD-59092) use the same principle.

Equipment and methods that supports DualGround™ testing are associated with the DualGround symbol. This symbol certifies the use of groundbreaking technology and methods that enables a safe, fast and easy work?ow with both sides grounded throughout the test.∏∏

Megger BD-59090-US Specifications

Application Field For use in high-voltage substations and industrial environments.
Relative Humidity %RH 5%-95%, non condensing
Pollution Degree 2
Shock IEC 60068-2-27
Vibration Vibration IEC 60068-2-6
Transport ISTA 2A
Battery Power Five AA (HR6) 2700 mAh NiMH cells
Recharge Time < 12 h
Battery Charger Mains Voltage 100 - 250 V AC, 50 / 60 Hz
Power Consumption 60 W
Protection Against wrong battery type, low/high temperature
Real Time Clock Battery Life =10 years
Audible Feedback Different buzzer sounds
User Presets 3
Field Calibration Yes
Encapsulation IP54
Dimensions 217 H x 92 B x 72 D mm
Weight 1.0 kg (2.2 lbs) instrument only
Click here for complete specifications on the Megger BD-59090-US

What's included with the Megger BD-59090-US

  • MOM2 Micro-Ohmmeter
  • 4 ft. (1.3 m) Red Test Cable with Kelvin Clamp
  • 10 ft. (3 m) Black Test Cable with Kelvin Clamp
  • Transport Case
  • Charger
  • Rubber Holster
  • Carrying Strap
  • Belt Clip
  • MOM2 Win Software

Ask a question about Megger BD-59090 MOM2 Micro-Ohmmeter, Kelvin Probes, 240A

Customer Reviews for the Megger BD-59090-US

More Megger Products