Work with an all-in-one depyrogenation solution with this data logging system data high-temperature enclosure, which includes a HiTemp140-M12 high-temperature data logger and a depyrogenation M12 probe. In addition, this system can withstand and measure temperatures up to 752°F (400°C).
Work with an all-in-one depyrogenation solution with this data logging system data high-temperature enclosure, which includes a HiTemp140-M12 high-temperature data logger and a depyrogenation M12 probe. In addition, this system can withstand and measure temperatures up to 752°F (400°C).
This system is capable of withstanding and measuring temperatures up to 400°C, allowing it to record throughout the entire sterilization process. The HiTemp140-M12 data logger features the popular rugged steel body design of the HiTemp140 data logger series with the flexibility to utilize dozens of RTD probe options with M12 connection compatibility.
The MadgeTech software allows for fast and easy data logger configuration. Simply insert the data logger into the IFC400 or IFC406 docking station (sold separately), choose either immediate or delay start and the desired reading rate. Insert the data logger onto the ThermoVault Max enclosure and screw the cap back on securely. The device is ready to be deployed.
Features
Applications
Temperature Sensor | 36 inch Glass Braided RTD depyrogenation probe |
Temperature Resolution | 0.0001 Ω, 0.01 °C (0.02 °F) |
Temperature Accuracy | ±1.2 °C (-200 °C to +400 °C) |
Memory | 43,690 readings |
Reading Rate | 4 readings per second up to 1 reading every 24 hours |
Required Interface Package | IFC400 or IFC406 |
Baud Rate | 125,000 |
Typical Battery Life | 1 year typical (1 minute reading rate at +25°C/+77°F) |
Barrier Material | 316 Stainless Steel, PTFE, Silicone |
Barrier Dimensions | 1.75 in OD x 9.6 in L (44.45 mm OD x 243.8 mm L) |
Barrier Dimensions | This device is not IP rated and is for use in dry applications only |
Approvals | CE |
Temperature Sensor | 36 inch Glass Braided RTD depyrogenation probe |
Temperature Resolution | 0.0001 Ω, 0.01 °C (0.02 °F) |
Temperature Accuracy | ±1.2 °C (-200 °C to +400 °C) |
Memory | 43,690 readings |
Reading Rate | 4 readings per second up to 1 reading every 24 hours |
Required Interface Package | IFC400 or IFC406 |
Baud Rate | 125,000 |
Typical Battery Life | 1 year typical (1 minute reading rate at +25°C/+77°F) |
Barrier Material | 316 Stainless Steel, PTFE, Silicone |
Barrier Dimensions | 1.75 in OD x 9.6 in L (44.45 mm OD x 243.8 mm L) |
Barrier Dimensions | This device is not IP rated and is for use in dry applications only |
Approvals | CE |