MadgeTech CT-H600 Current Transformer, 200A

Model: CT-H600

MadgeTech CT-H600 Current Transformer, 200A

Model: CT-H600

Split core current transformer monitors from 1.5 to 200A with fixed setpoints at 0.15A max and no status LEDs.

Split core current transformer monitors from 1.5 to 200A with fixed setpoints at 0.15A max and no status LEDs.

Your Price $109.00 USD
Availability 2 to 3 Weeks
Quantity

MadgeTech CT-H600 Offers

Features

  • Monitors 0.15 to 200 A
  • Fixed set-points at 0.15 A maximum
  • No status LED's

MadgeTech CT-H600 Specifications

Sensor Power Induced from monitored conductor
Amperage Range 0.15 to 200 A Continuous
Status Output Ratings N.O. 1 A at 30 VAC/DC not polarity sensitive
Insulation Class 600 VAC RMS (UL), 300 VAC RMS (CE)
Setpoint Fixed at 0.15 A maximum (60 Hz)
Frequency 50/60 Hz
Temperature Range 5 to 104°F (-15 to 40°C)
Humidity Range 10 to 90% RH non-condensing
Off State Resistance Open switch represents 1+ MΩ
On State Resistance Closed switch represents <200 mΩ
Terminal Block Wire Size: 14 to 24 AWG (2.1 to 0.2 mm⊃2)
Torque: 3.5 to 4.5 in-lb (0.4 to 0.5 N-m)
Agency Approvals UL508, CE: EN61010-1
Installation Category Cat. III, pollution degree 2
Click here for complete specifications on the MadgeTech CT-H600

What's included with the MadgeTech CT-H600

  • MadgeTech CT-H600 Current Transformer, 200A

Ask a question about MadgeTech CT-H600 Current Transformer, 200A

Customer Reviews for the MadgeTech CT-H600

MadgeTech CT-H600 Offers

Features

  • Monitors 0.15 to 200 A
  • Fixed set-points at 0.15 A maximum
  • No status LED's

MadgeTech CT-H600 Specifications

Sensor Power Induced from monitored conductor
Amperage Range 0.15 to 200 A Continuous
Status Output Ratings N.O. 1 A at 30 VAC/DC not polarity sensitive
Insulation Class 600 VAC RMS (UL), 300 VAC RMS (CE)
Setpoint Fixed at 0.15 A maximum (60 Hz)
Frequency 50/60 Hz
Temperature Range 5 to 104°F (-15 to 40°C)
Humidity Range 10 to 90% RH non-condensing
Off State Resistance Open switch represents 1+ MΩ
On State Resistance Closed switch represents <200 mΩ
Terminal Block Wire Size: 14 to 24 AWG (2.1 to 0.2 mm⊃2)
Torque: 3.5 to 4.5 in-lb (0.4 to 0.5 N-m)
Agency Approvals UL508, CE: EN61010-1
Installation Category Cat. III, pollution degree 2