Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure

Model: 4OUMR-01M | Order No: 4OUMR-1M | UPC: 078477702369

Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure

Model: 4OUMR-01M | Order No: 4OUMR-1M | UPC: 078477702369

The Leviton 4OUMR-01M outdoor series 4000 ModBus meter kit is a revenue-grade kWh electrical meter. This device combines exceptional performance and easy installation for a cost-effective energy monitoring solution.

The Leviton 4OUMR-01M outdoor series 4000 ModBus meter kit is a revenue-grade kWh electrical meter. This device combines exceptional performance and easy installation for a cost-effective energy monitoring solution.

Sale Price $1088.36 USD
Regular Price $1183.00 USD
Availability 1 to 2 Weeks
Quantity

Leviton 4OUMR-01M Offers

Features

  • Industrial temperature range: -22 to 158°F (-30 to 70°C)
  • 50/60 Hz
  • 90-600V versatility including 347V (L-N) and 600V (L-L)
  • Resettable kWh feature meets requirements for Title 24 and Seattle Energy Code Rogowski CT Options (20-5000A)
  • DIN rail mount
  • Five year warranty

Applications

Use the VerifEye Series 4000 Industrial ModBus Meter Kits in commercial, institutional, industrial and government applications for:

  • Energy monitoring for AMR/BAS/BMS/EMS systems
  • Tenant cost allocation
  • Energy conservation and cost reduction
  • Green building initiatives and government mandates
  • Measurement and verification
  • Load profiling and benchmarking

Leviton 4OUMR-01M Specifications

Measurement Accuracy
Real Power and Energy IEC 62053-22 Class 0.5S, ANSI C12.20 0.5%
Reactive Power and Energy IEC 62053-23 Class 2, 2%
Current 0.4% (+0.015% per °C deviation from 25°C) from 5% to 100% of range; 0.8% (+0.015% per °C deviation from 25°C) from 1% to 5% of range
Voltage 0.4% (+0.015% per °C deviation from 25°C) from 90VL-N to 600VACL-L
Sample Rate 2520 Samples Per Second
Data Update Rate 1 sec
Type of Measurement True RMS up to the 21st harmonic 60 Hz; One to three phase AC system
Input Voltage
Measured AC Voltage Minimum 90VL-N (156VL-L) for stated accuracy
UL Maximums: 600VL-L (347VL-N)
CE Maximum: 300VL-N
Metering Over-Range +20%
Impedance 2.5 MΩ L-N /5 MΩ L-L
Frequency Range 45 to 65 Hz
Input Current
CT Scaling Primary: Adjustable from 5 A to 32,000 A
Measurement Input Range 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range), rated for use with Class 1 voltage inputs
Impedance 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode)
Control Power
AC 5VA max.; 90V min.
UL Maximums: 600VL-L (347 VL-N )
CE Maximum: 300VL-N
DC 3 W max.; UL and CE: 125 to 300VDC
Ride Through Time 100 msec at 120VAC
Output
Alarm Contacts N.C., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C)
Real Energy Pulse Contacts N.O., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C)
RS-485 Port 2-wire, 1200 to 38400 baud, Modbus RTU
Mechanical
Weight 0.62 lb (0.28 kg)
IP Degree of Protection (IEC 60529) IP40 front display; IP20 Meter
Display Characteristics Back-lit blue LCD
Terminal Block Screw Torque 0.37 to 0.44 ft-lb (0.5 to 0.6 N·m)
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm2)
Rail T35 (35mm) DIN Rail per EN50022
Operating Conditions
Operating Temperature Range -30° to 70°C (-22° to 158°F)
Storage Temperature Range -40° to 85°C (-40° to 185°F)
Humidity Range <95% RH noncondensing
Altitude of Operation 3000 m
Compliance Information
US and Canada CAT III, Pollution Degree 2
For distribution systems up to 347VL-N /600VACL-L
CE CAT III, Pollution Degree 2
For distribution systems up to 300VL-N
Dielectric Withstand Per UL 508, EN61010
Conducted and Radiated Emissions FCC Part 15 Class B, EN55011/EN61000 Class B (Residential and Light Industrial)
Conducted and Radiated Immunity EN61000 Class A (Heavy Industrial)
US and Canada (cULus) UL508 (Open Type Device)/CSA 22.2 No. 14-05
Europe (CE) EN61010-1
Click here for complete specifications on the Leviton 4OUMR-01M

What's included with the Leviton 4OUMR-01M

  • Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure

Click on a category to view a selection of compatible accessories with the Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure.

Ask a question about Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure

Customer Reviews for the Leviton 4OUMR-01M

Leviton 4OUMR-01M Offers

Features

  • Industrial temperature range: -22 to 158°F (-30 to 70°C)
  • 50/60 Hz
  • 90-600V versatility including 347V (L-N) and 600V (L-L)
  • Resettable kWh feature meets requirements for Title 24 and Seattle Energy Code Rogowski CT Options (20-5000A)
  • DIN rail mount
  • Five year warranty

Applications

Use the VerifEye Series 4000 Industrial ModBus Meter Kits in commercial, institutional, industrial and government applications for:

  • Energy monitoring for AMR/BAS/BMS/EMS systems
  • Tenant cost allocation
  • Energy conservation and cost reduction
  • Green building initiatives and government mandates
  • Measurement and verification
  • Load profiling and benchmarking

Leviton 4OUMR-01M Specifications

Measurement Accuracy
Real Power and Energy IEC 62053-22 Class 0.5S, ANSI C12.20 0.5%
Reactive Power and Energy IEC 62053-23 Class 2, 2%
Current 0.4% (+0.015% per °C deviation from 25°C) from 5% to 100% of range; 0.8% (+0.015% per °C deviation from 25°C) from 1% to 5% of range
Voltage 0.4% (+0.015% per °C deviation from 25°C) from 90VL-N to 600VACL-L
Sample Rate 2520 Samples Per Second
Data Update Rate 1 sec
Type of Measurement True RMS up to the 21st harmonic 60 Hz; One to three phase AC system
Input Voltage
Measured AC Voltage Minimum 90VL-N (156VL-L) for stated accuracy
UL Maximums: 600VL-L (347VL-N)
CE Maximum: 300VL-N
Metering Over-Range +20%
Impedance 2.5 MΩ L-N /5 MΩ L-L
Frequency Range 45 to 65 Hz
Input Current
CT Scaling Primary: Adjustable from 5 A to 32,000 A
Measurement Input Range 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range), rated for use with Class 1 voltage inputs
Impedance 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode)
Control Power
AC 5VA max.; 90V min.
UL Maximums: 600VL-L (347 VL-N )
CE Maximum: 300VL-N
DC 3 W max.; UL and CE: 125 to 300VDC
Ride Through Time 100 msec at 120VAC
Output
Alarm Contacts N.C., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C)
Real Energy Pulse Contacts N.O., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C)
RS-485 Port 2-wire, 1200 to 38400 baud, Modbus RTU
Mechanical
Weight 0.62 lb (0.28 kg)
IP Degree of Protection (IEC 60529) IP40 front display; IP20 Meter
Display Characteristics Back-lit blue LCD
Terminal Block Screw Torque 0.37 to 0.44 ft-lb (0.5 to 0.6 N·m)
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm2)
Rail T35 (35mm) DIN Rail per EN50022
Operating Conditions
Operating Temperature Range -30° to 70°C (-22° to 158°F)
Storage Temperature Range -40° to 85°C (-40° to 185°F)
Humidity Range <95% RH noncondensing
Altitude of Operation 3000 m
Compliance Information
US and Canada CAT III, Pollution Degree 2
For distribution systems up to 347VL-N /600VACL-L
CE CAT III, Pollution Degree 2
For distribution systems up to 300VL-N
Dielectric Withstand Per UL 508, EN61010
Conducted and Radiated Emissions FCC Part 15 Class B, EN55011/EN61000 Class B (Residential and Light Industrial)
Conducted and Radiated Immunity EN61000 Class A (Heavy Industrial)
US and Canada (cULus) UL508 (Open Type Device)/CSA 22.2 No. 14-05
Europe (CE) EN61010-1
Click here for complete specifications on the Leviton 4OUMR-01M

What's included with the Leviton 4OUMR-01M

  • Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure

Click on a category to view a selection of compatible accessories with the Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure.

Ask a question about Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure

Customer Reviews for the Leviton 4OUMR-01M

More Leviton Products

Calibration Lab