The Leviton 4OUMR-01M outdoor series 4000 ModBus meter kit is a revenue-grade kWh electrical meter. This device combines exceptional performance and easy installation for a cost-effective energy monitoring solution.
The Leviton 4OUMR-01M outdoor series 4000 ModBus meter kit is a revenue-grade kWh electrical meter. This device combines exceptional performance and easy installation for a cost-effective energy monitoring solution.
Features
Applications
Use the VerifEye Series 4000 Industrial ModBus Meter Kits in commercial, institutional, industrial and government applications for:
Measurement Accuracy | |
Real Power and Energy | IEC 62053-22 Class 0.5S, ANSI C12.20 0.5% |
Reactive Power and Energy | IEC 62053-23 Class 2, 2% |
Current | 0.4% (+0.015% per °C deviation from 25°C) from 5% to 100% of range; 0.8% (+0.015% per °C deviation from 25°C) from 1% to 5% of range |
Voltage | 0.4% (+0.015% per °C deviation from 25°C) from 90VL-N to 600VACL-L |
Sample Rate | 2520 Samples Per Second |
Data Update Rate | 1 sec |
Type of Measurement | True RMS up to the 21st harmonic 60 Hz; One to three phase AC system |
Input Voltage | |
Measured AC Voltage | Minimum 90VL-N (156VL-L) for stated accuracy UL Maximums: 600VL-L (347VL-N) CE Maximum: 300VL-N |
Metering Over-Range | +20% |
Impedance | 2.5 MΩ L-N /5 MΩ L-L |
Frequency Range | 45 to 65 Hz |
Input Current | |
CT Scaling | Primary: Adjustable from 5 A to 32,000 A |
Measurement Input Range | 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range), rated for use with Class 1 voltage inputs |
Impedance | 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode) |
Control Power | |
AC | 5VA max.; 90V min. UL Maximums: 600VL-L (347 VL-N ) CE Maximum: 300VL-N |
DC | 3 W max.; UL and CE: 125 to 300VDC |
Ride Through Time | 100 msec at 120VAC |
Output | |
Alarm Contacts | N.C., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
Real Energy Pulse Contacts | N.O., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
RS-485 Port | 2-wire, 1200 to 38400 baud, Modbus RTU |
Mechanical | |
Weight | 0.62 lb (0.28 kg) |
IP Degree of Protection (IEC 60529) | IP40 front display; IP20 Meter |
Display Characteristics | Back-lit blue LCD |
Terminal Block Screw Torque | 0.37 to 0.44 ft-lb (0.5 to 0.6 N·m) |
Terminal Block Wire Size | 24 to 14 AWG (0.2 to 2.1 mm2) |
Rail | T35 (35mm) DIN Rail per EN50022 |
Operating Conditions | |
Operating Temperature Range | -30° to 70°C (-22° to 158°F) |
Storage Temperature Range | -40° to 85°C (-40° to 185°F) |
Humidity Range | <95% RH noncondensing |
Altitude of Operation | 3000 m |
Compliance Information | |
US and Canada | CAT III, Pollution Degree 2 For distribution systems up to 347VL-N /600VACL-L |
CE | CAT III, Pollution Degree 2 For distribution systems up to 300VL-N |
Dielectric Withstand | Per UL 508, EN61010 |
Conducted and Radiated Emissions | FCC Part 15 Class B, EN55011/EN61000 Class B (Residential and Light Industrial) |
Conducted and Radiated Immunity | EN61000 Class A (Heavy Industrial) |
US and Canada (cULus) | UL508 (Open Type Device)/CSA 22.2 No. 14-05 |
Europe (CE) | EN61010-1 |
Click on a category to view a selection of compatible accessories with the Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure.
Measurement Accuracy | |
Real Power and Energy | IEC 62053-22 Class 0.5S, ANSI C12.20 0.5% |
Reactive Power and Energy | IEC 62053-23 Class 2, 2% |
Current | 0.4% (+0.015% per °C deviation from 25°C) from 5% to 100% of range; 0.8% (+0.015% per °C deviation from 25°C) from 1% to 5% of range |
Voltage | 0.4% (+0.015% per °C deviation from 25°C) from 90VL-N to 600VACL-L |
Sample Rate | 2520 Samples Per Second |
Data Update Rate | 1 sec |
Type of Measurement | True RMS up to the 21st harmonic 60 Hz; One to three phase AC system |
Input Voltage | |
Measured AC Voltage | Minimum 90VL-N (156VL-L) for stated accuracy UL Maximums: 600VL-L (347VL-N) CE Maximum: 300VL-N |
Metering Over-Range | +20% |
Impedance | 2.5 MΩ L-N /5 MΩ L-L |
Frequency Range | 45 to 65 Hz |
Input Current | |
CT Scaling | Primary: Adjustable from 5 A to 32,000 A |
Measurement Input Range | 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range), rated for use with Class 1 voltage inputs |
Impedance | 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode) |
Control Power | |
AC | 5VA max.; 90V min. UL Maximums: 600VL-L (347 VL-N ) CE Maximum: 300VL-N |
DC | 3 W max.; UL and CE: 125 to 300VDC |
Ride Through Time | 100 msec at 120VAC |
Output | |
Alarm Contacts | N.C., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
Real Energy Pulse Contacts | N.O., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
RS-485 Port | 2-wire, 1200 to 38400 baud, Modbus RTU |
Mechanical | |
Weight | 0.62 lb (0.28 kg) |
IP Degree of Protection (IEC 60529) | IP40 front display; IP20 Meter |
Display Characteristics | Back-lit blue LCD |
Terminal Block Screw Torque | 0.37 to 0.44 ft-lb (0.5 to 0.6 N·m) |
Terminal Block Wire Size | 24 to 14 AWG (0.2 to 2.1 mm2) |
Rail | T35 (35mm) DIN Rail per EN50022 |
Operating Conditions | |
Operating Temperature Range | -30° to 70°C (-22° to 158°F) |
Storage Temperature Range | -40° to 85°C (-40° to 185°F) |
Humidity Range | <95% RH noncondensing |
Altitude of Operation | 3000 m |
Compliance Information | |
US and Canada | CAT III, Pollution Degree 2 For distribution systems up to 347VL-N /600VACL-L |
CE | CAT III, Pollution Degree 2 For distribution systems up to 300VL-N |
Dielectric Withstand | Per UL 508, EN61010 |
Conducted and Radiated Emissions | FCC Part 15 Class B, EN55011/EN61000 Class B (Residential and Light Industrial) |
Conducted and Radiated Immunity | EN61000 Class A (Heavy Industrial) |
US and Canada (cULus) | UL508 (Open Type Device)/CSA 22.2 No. 14-05 |
Europe (CE) | EN61010-1 |
Click on a category to view a selection of compatible accessories with the Leviton 4OUMR-01M Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits 100A Split Core CTs Included in NEMA 4X Enclosure.