Hioki PQ3198/600 Power Quality Analyzer Kit, 600 A

Model: PQ3198/600 KIT | Order No: PQ3198/600

Hioki PQ3198/600 Power Quality Analyzer Kit, 600 A

Model: PQ3198/600 KIT | Order No: PQ3198/600

The 600 A analyzer kit monitors and records power supply anomalies and assesses power supply problems such as voltage drops, flicker, harmonics, and other electrical issues. It features the ability to drive current sensors straight from the PQA and enhanced recording capabilities.

The 600 A analyzer kit monitors and records power supply anomalies and assesses power supply problems such as voltage drops, flicker, harmonics, and other electrical issues. It features the ability to drive current sensors straight from the PQA and enhanced recording capabilities.

Your Price $9119.00 USD
Availability 2 to 3 Weeks
Quantity

Hioki PQ3198/600 KIT Offers

Features

  • A simple inverter measurement
  • Class A compliance under international standards
  • Basic voltage measurement accuracy of ±0.1%
  • High-voltage, wideband performance
  • Two-circuit measurement
  • 400 Hz line measurement
  • GPS time synchronization
  • Extensive array of event measurement parameters

Applications

  • Investigate power supply anomalies
  • Verify the quality of power from solar power systems
  • Verify the quality of power supplied by EV rapid chargers

Hioki PQ3198/600 KIT Specifications

Voltage Ranges Voltage measurement: 600.00 V rms
Transient measurement 6.0000 kV peak
Current Ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use)
Power Ranges 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic Accuracy Voltage: ±0.1% of nominal voltage
Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurement Items 1. Transient voltage : 2 MHz sampling
2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
Current (1/2) RMS: half-cycle calculation
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz
9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz
10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency
12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders
14. Harmonic voltage-current phase angle: 1th to 50 th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order
17. K Factor (multiplication factor)
18. IEC Flicker, Δ V10 Flicker
Record Repeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
Intefaces SD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication)
Display 6.5-inch TFT color LCD (640 × 480 dots)
Power Supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack Z1003 (Continuous use: 180 minutes, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions 11.81 x 8.31 x 2.68" (300 x 211 x 68 mm)
Weight 91.7 oz (2.6 kg)(including battery pack z1003)
Click here for complete specifications on the Hioki PQ3198/600 KIT

What's included with the Hioki PQ3198/600 KIT

  • Power Quality Analyzer
  • Voltage Cord (L1000)
  • AC Adapter, 100 V - 240 VAC (Z1002)
  • Battery Pack, 7.2 V, Ni-MH (Z1003)
  • 4 x AC Current Sensors, 600 A - CT7136
  • 4 x Patch Cords (Black) - L1021-02
  • 4 x Magnetic Adapters (Red) - 9804-01
  • 4 x Magnetic Adapters (Black) - 9804-02
  • SD Memory Card (8 GB)
  • Hard Case

Ask a question about Hioki PQ3198/600 Power Quality Analyzer Kit, 600 A

Customer Reviews for the Hioki PQ3198/600 KIT

Hioki PQ3198/600 KIT Offers

Features

  • A simple inverter measurement
  • Class A compliance under international standards
  • Basic voltage measurement accuracy of ±0.1%
  • High-voltage, wideband performance
  • Two-circuit measurement
  • 400 Hz line measurement
  • GPS time synchronization
  • Extensive array of event measurement parameters

Applications

  • Investigate power supply anomalies
  • Verify the quality of power from solar power systems
  • Verify the quality of power supplied by EV rapid chargers

Hioki PQ3198/600 KIT Specifications

Voltage Ranges Voltage measurement: 600.00 V rms
Transient measurement 6.0000 kV peak
Current Ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use)
Power Ranges 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic Accuracy Voltage: ±0.1% of nominal voltage
Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurement Items 1. Transient voltage : 2 MHz sampling
2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
Current (1/2) RMS: half-cycle calculation
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz
9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz
10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency
12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders
14. Harmonic voltage-current phase angle: 1th to 50 th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order
17. K Factor (multiplication factor)
18. IEC Flicker, Δ V10 Flicker
Record Repeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
Intefaces SD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication)
Display 6.5-inch TFT color LCD (640 × 480 dots)
Power Supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack Z1003 (Continuous use: 180 minutes, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions 11.81 x 8.31 x 2.68" (300 x 211 x 68 mm)
Weight 91.7 oz (2.6 kg)(including battery pack z1003)
Click here for complete specifications on the Hioki PQ3198/600 KIT

What's included with the Hioki PQ3198/600 KIT

  • Power Quality Analyzer
  • Voltage Cord (L1000)
  • AC Adapter, 100 V - 240 VAC (Z1002)
  • Battery Pack, 7.2 V, Ni-MH (Z1003)
  • 4 x AC Current Sensors, 600 A - CT7136
  • 4 x Patch Cords (Black) - L1021-02
  • 4 x Magnetic Adapters (Red) - 9804-01
  • 4 x Magnetic Adapters (Black) - 9804-02
  • SD Memory Card (8 GB)
  • Hard Case

Ask a question about Hioki PQ3198/600 Power Quality Analyzer Kit, 600 A

Customer Reviews for the Hioki PQ3198/600 KIT

More Hioki Products

Calibration Lab