Hioki IM3533 LCR Meter

Model: IM3533

Hioki IM3533 LCR Meter

Model: IM3533

The LCR meter offers turn ratio, mutual inductance, and inductance difference measurements of transformers and coils. It is integrated with an internal DC bias to facilitate HDMI compliance testing. It is also useful in production lines as well as in the research and development of transformers and coils.

The LCR meter offers turn ratio, mutual inductance, and inductance difference measurements of transformers and coils. It is integrated with an internal DC bias to facilitate HDMI compliance testing. It is also useful in production lines as well as in the research and development of transformers and coils.

Your Price $4345.00 USD
Availability 2 to 3 Weeks
Quantity

Hioki IM3533 LCR Meter

Features

  • A single device can perform measurements at high speed undermultiple conditions.(C-D + ESR measurement and L + DCR measurement)
  • Optimal measurement conditions can be set automatically accordingto the test sample so switching between setups is a snap.
  • DCR temperature compensation (DCR temperature compensationfunction).
  • All the measurements necessary to evaluate transformers (such asturn ratio and mutual inductance) in a single device.
  • Compact size with a depth of approximately 168 mm (6.61 in)leaves ample room for other equipment.

Hioki IM3533 Specifications

Measurement Modes LCR (Measurement with single condition), Transformer testing (N, M, ΔL), Continuous testing(Continuous measurement under saved conditions) (LCR mode)
Measurement Parameters Z, Y, Θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), N, M, ΔL, T
Measurement Range 100 mΩ to 100 MΩ, 10 ranges (All parameters defined in terms of Z.)
Displayable Range Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :± (0.00000 [unit] to 9.99999G [unit]) Real value display for Z and Y only
Θ:± (0.000° to 180.000°)
D:± (0.00000 to 9.99999)
Q:± (0.00 to 99999.9), Δ%:± (0.0000% to 999.999%)
T: -10.0°C to 99.9°C
Basic Accuracy Z :±0.05% rdg.
Θ:±0.03°
Measurement Frequency 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz)
Measurement Signal Level [Normal mode] V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
[Low impedance high accuracy mode] V mode, CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
CC mode: 10 μA to 100 mArms, 10 μArms steps
Output Impedance Normal mode: 100 Ω
Low impedance high accuracy mode: 25 Ω
Display 5.7" touch-screen color TFT, display can be set to ON/OFF
Measurement Time 2 ms (1 kHz, FAST, display OFF, representative value)
Functions DC bias measurement, DC resistance temperature compensation (converted reference temperature display), Comparator, BIN measurement (classify function), Panel loading/saving, Memory function
Interfaces EXT I/O (Handler), USB communication (high-speed), USB memory
Optional: Choose 1 from RS-232C, GP-IB, or LAN
Power Supply 100 to 240 V AC, 50/60 Hz, 50 VA max
Dimensions 12.99 x 4.69 x 6.61" (330 x 119 x 168 mm)
Weight 109.3 oz (3.1 kg)
Click here for complete specifications on the Hioki IM3533

What's included with the Hioki IM3533

  • LCR Meter
  • Power cord
  • CD-R
  • Instruction manual

Ask a question about Hioki IM3533 LCR Meter

Customer Reviews for the Hioki IM3533

Hioki IM3533 LCR Meter

Features

  • A single device can perform measurements at high speed undermultiple conditions.(C-D + ESR measurement and L + DCR measurement)
  • Optimal measurement conditions can be set automatically accordingto the test sample so switching between setups is a snap.
  • DCR temperature compensation (DCR temperature compensationfunction).
  • All the measurements necessary to evaluate transformers (such asturn ratio and mutual inductance) in a single device.
  • Compact size with a depth of approximately 168 mm (6.61 in)leaves ample room for other equipment.

Hioki IM3533 Specifications

Measurement Modes LCR (Measurement with single condition), Transformer testing (N, M, ΔL), Continuous testing(Continuous measurement under saved conditions) (LCR mode)
Measurement Parameters Z, Y, Θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), N, M, ΔL, T
Measurement Range 100 mΩ to 100 MΩ, 10 ranges (All parameters defined in terms of Z.)
Displayable Range Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :± (0.00000 [unit] to 9.99999G [unit]) Real value display for Z and Y only
Θ:± (0.000° to 180.000°)
D:± (0.00000 to 9.99999)
Q:± (0.00 to 99999.9), Δ%:± (0.0000% to 999.999%)
T: -10.0°C to 99.9°C
Basic Accuracy Z :±0.05% rdg.
Θ:±0.03°
Measurement Frequency 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz)
Measurement Signal Level [Normal mode] V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
[Low impedance high accuracy mode] V mode, CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
CC mode: 10 μA to 100 mArms, 10 μArms steps
Output Impedance Normal mode: 100 Ω
Low impedance high accuracy mode: 25 Ω
Display 5.7" touch-screen color TFT, display can be set to ON/OFF
Measurement Time 2 ms (1 kHz, FAST, display OFF, representative value)
Functions DC bias measurement, DC resistance temperature compensation (converted reference temperature display), Comparator, BIN measurement (classify function), Panel loading/saving, Memory function
Interfaces EXT I/O (Handler), USB communication (high-speed), USB memory
Optional: Choose 1 from RS-232C, GP-IB, or LAN
Power Supply 100 to 240 V AC, 50/60 Hz, 50 VA max
Dimensions 12.99 x 4.69 x 6.61" (330 x 119 x 168 mm)
Weight 109.3 oz (3.1 kg)
Click here for complete specifications on the Hioki IM3533

What's included with the Hioki IM3533

  • LCR Meter
  • Power cord
  • CD-R
  • Instruction manual

Ask a question about Hioki IM3533 LCR Meter