GRAPHTEC GL840-M Midi Data Logger, 20 channel, multi-input type

Model: GL840-M

GRAPHTEC GL840-M Midi Data Logger, 20 channel, multi-input type

Model: GL840-M

Suitable for temperature measurement with multiple channels, this multi-input type midi data logger features a 7" (177.8 mm) easy-to-read wide color LCD with a 20-channel configuration that is expandable up to 200 channels. In addition, this data logger accommodates a variety of measurements with many functions.

Suitable for temperature measurement with multiple channels, this multi-input type midi data logger features a 7" (177.8 mm) easy-to-read wide color LCD with a 20-channel configuration that is expandable up to 200 channels. In addition, this data logger accommodates a variety of measurements with many functions.

Your Price $2395.00 USD
Availability 11 to 12 Weeks
Quantity

GRAPHTEC GL840-M Offers

Work with reliable and long-term measurements with this data logger that supports large-size SD cards. In addition, this data logger has a flexible input system to suit many applications, smartphone and remote access monitoring, and a maximum sampling interval of up to 10 ms.

Features

  • Multi-channel type
  • Large easy-to-read 7" (177.8 mm) wide color LCD: Carries a clear 7" (177.8 mm) wide TFT color LCD screen (WVGA: 800 x 480 dots) for this data logger, and 4.3" (109.22 mm) wide LCD screen monitoring data are displayed in waveform or digital form option and parameter settings can be displayed on the screen.
  • Expandable up to 200 channels: Standard configuration has 20 analog input channels and it is expandable to 200 channels by adding the optional 20 channel extension terminal base unit B-566 (sold separately) and input terminal unit B-564 (sold separately)
  • Wireless LAN capability, remote monitoring and datalogging
  • Flexible input system for wide array of applications, RTD, T/C
  • Ability to access additional (GL100) sensors and adapters
  • Extended memory capacity using SD memory card
  • Smartphone, remote access monitoring
  • All channel isolated/analog signal input port
  • Logic/pulse signal input port
  • USB2.0
  • Ethernet (10BASE-T/100BASE-TX)
  • SD card slot for SDHC memory card
  • Support digital sensors: Digital sensors and input terminal/adapters for the GL100 connects to this data logger directly
  • Easy operation with control button
  • Three types of input systems enable measurement of various signals: Along with the basic analog signal, logic/pulse, and digital sensors can be all connected to monitor a variety of measurements
  • Control settings
  • Maximum sampling interval of up to 10 ms: Provides faster sampling rates for voltage measurements and you are able to achieve up to 10 ms sampling speed when limiting the number of channels in use.
  • Alarm output function: Based on set conditions for each channels, alarm signals can be placed using the four channel alarm output ports (*Input/output cable B-513 option {sold seperately} is required to connect the alarm output ports to external buzzer/light mechanism)
  • Navigation feature: Simple to use navigation screen allows setting operation for measurement and wireless LAN adapter (sold separately)
  • Ring capture function: The most recent data is saved when the memory is configured in ring memory mode (Number of capturing data is 1000 to 2,000,000 points)
  • Relay capture function: Data is continuously saved to multiple files up to 2 GB without losing any data until capturing is stopped when the memory is configured in the relay mode
  • Hot-swapping the SD memory card: SD card can be replaced during data capturing when the sampling interval is 100 ms or slower
  • USB drive mode: USB drive mode function enables data to be transferred to the PC from this data logger by drag and drop feature

Input

  • Adoption of a pluggable M3 screw type input terminal facilitates wiring
  • 20 channel measurements are supported by the standard terminal, and 200 channel measurements are supported by the extension terminal base
  • When using the GS series and terminal/adapter, the acceleration, AC current, CO2, and illuminance/ultraviolet measurements are also possible
  • Because that standard terminal has a whole CH isolated, the different standard signals can be measured at the same time

Display and operation

  • With this data loggers high-resolution 7" (177.8 mm) TFT color liquid crystal display, you can confirm the waveforms of measured data and each channel's settings at a glance
  • Easy operation is achieved through a straightforward menu structure and key allocation which resembles mobile phones

Data capture

  • Data is directly saved to the large SD memory card (Standard accessory: 4 GB)
  • Their two mounting slots for the SD memory card and long-term measurement can be performed while backing up the data (*When the optional wireless LAN unit {sold separately} is installed, the SD memory card cannot be inserted into the SD CARD2 slot)
  • Because disk image can be used for the SD memory card , multiple data can be saved
  • The new ring memory capture function maintains latest data even after capturing for a long term (You need to set how long you want to keep data)
  • For voltage, temperature and humidity measurements, data can be captured at sampling rates of up to 10 msec per channel by using fewer measuring channels (Temperature measurement can be done at sampling rates of 100 msec and higher)
  • This data logger is equipped with the relay recording function, and 2 GB or more data can be saved by switching the to the other file without data missing (When the capacity of one file reaches 2 GB, the file is switched)

Data control and processing

  • The application software provided lets you set conditions and monitor data on a PC
  • The USB drive mode function enables the SD memory card to be recognized as an external drive by the PC (Connect this data logger to the PC and turn on the data logger power while holding down the {START} key)
  • The WEB server function enables control and monitoring from a remote location without using dedicated software
  • The FTP client function enables backup of measurement data to the FTP server
  • The NTP client function enables synchronization of the time with the NTP server
  • When optional wireless LAN unit is installed (sold separately), the data capture can be performed remotely by controlling the GL100-WL

Networking features

  • Web and FTP server function: This data logger can be controlled externally via a network on the WEB browser, which also supports monitoring and transfer of signals and captured data
  • FTP client function: Captured data is periodically transferred to the FTP server for backup
  • NTP client function: The clock on this data logger is periodically synchronized with the NPT server (This data logger needs to be connected to a LAN environment using the available Ethernet/WLAN ports)

The GL series carries two SD memory card slots for storage device. The SDHC type SD memory card is supported up to 32 GB. 4 GB SD memory card comes as a standard accessory installed in the first slot.

Accommodates a wide variety of measurements

Multifunction analog input ports: Contains a highly isolated input mechanism which ensures that signals are not corrupted by noise from other channels. This data loggers inputs are suitable for combined measurements from voltage, temperature, humidity, logic, and pulse signals.
Four channels if logic/pulse inputs: Supports four-channel logic or pulse signal inputs. Pulse mode allows cumulative, instant, or rotational values for industrial measurements capability with speed and flow.

Applications

  • Agriculture
  • Greenhouse and hydroponics
  • Construction and civil engineering
  • Machinery manufacturing
  • Automotive
  • Aerospace
  • Utilities/gas and electric
  • Electrical appliance and office equipment
  • Food processing

High performance software with useful functions for the PC

Supports GL840, GL240, GL100

Up to 10 units of GL840, GL240 and GL100 can be connected to one PC simultaneously. Up to 1000 channels are supported.

Various measurement screen

Display data in Y-T waveform, digital monitoring, statistical calculation result. The direct-Excel function enables captured data to be written directly to an Excel file.

File operation

Data capture in multiple files can be merged into a single file. Using the combine function, data can be imported as a new channel overlaying on top of each other. The bind function connects the data in a time axis. When using the relay capture mode, the bind feature will append multiple files together into one large, continuous file.

Useful functions

Scheduling function: Create a schedule for your monitoring to start and stop at selected time, and set an automatic measurement schedule.
Group function: Multiple units can be managed, such as controlling start or stop simultaneously. Data captured by each unit is saved in a single file.

Data format conversion

Converts the GBD (Graphtec Binary Data) format to CSV format. The file size is reduced using the compression function saving a value at particular time point of a specified interval. Or, it will save the average, maximum, or minimum values from the specified time intervals as the highlighted values.

High quality performance and measurement software with useful functions for the PC and smart device environment

For PC

  • Software for the PC is included as a standard accessory
  • Monitor and save captured data remotely
  • Control this data logger
  • Scheduling function
  • Group function
  • Data format conversion
  • File operation and more!

For smart device (GL-connect)

Apps for the smart devices are available on the Android OS and iOS platforms. Download them free from the individual stores.

Monitoring captured data: Real time captured data can be displayed as digital values in real time on the smart devices apps. The saved data on this data loggers main body can also be displayed in waveform display format (Captured data will not be saved on the smart device).

Set and control simple functions: Dedicated control features allow remote start and stop, setting the sampling interval, and setting the alarm conditions.

Control the settings remotely: Web server functions for this data logger allows remote control and monitoring using this application.

GRAPHTEC GL840-M Specifications

Number of Analog Input Channels: 20 channels in standard configuration, expandable up to 200 channels
Terminals: Up to 10 terminals (20 channels/terminals), standard configuration: 1
Type of Analog Input Terminal Multi-input type
Port for Digital Sensor 1 port for the sensor/input terminal/adapter of the GL100
External Input/Output*1 Input*2: Trigger or sampling (1 channel), logic/pulse (4 channels)
Output*3: Alarm (4 channels)
*1Input/output cable for GL (option B-513 is required to connect the signal.
*2Input signal:
Voltage range: Up to 24 V (common ground)
Signal type: Voltage, open collector, contact (relay)
Threshold: Approximately + 2.5 V (Hysteresis: Approximately 0.5 V (2.5 to 3 V)

*3Output signal: Open collector (pull-up to 5 V by 10 kΩ resistor)
Maximum rating of the output transistor
Voltage: Maximum 30 V
Current: Maximum 0.5 A
Collector dissipation: Maximum 0.2 W
Sampling Interval 10 ms to 1 hour (10 to 50 ms: voltage only)*4, external signal
*4Minimum interval varies by number of channels used.
Time Scale of Waveform Display 1 second to 24 hour/division
Trigger, Alarm Function Trigger action: Start or stop capturing data by the trigger

Repeat action: Off, On (auto rearmed)

Trigger source:
Start: Off, Measured signal, Alarm, External, Clock, Week or Time
Stop: Off, Measured signal, Alarm, External, Clock, Week or Time

Condition setting:
Combination: OR or AND
Analog signal: Rising (High), Falling (Low), Window-in, Window-out
Logic signal: Pattern (combination of each input signal in high or low)
Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out

Alarm output: Outputs a signal when alarm condition occurs in the input signal*5
*5Output port can be specified in each input channel.
Pulse Input Function Rotation count (RPM): Counts the number of pulses per sampling interval and converts to rpm (rotations per minutes), number of pulses for one rotation may be set to 50, 500, 5000, 50k, 500k, 5M, 50M, 500M rpm/F.S (rpm./full scale)
Accumulating count: Accumulates the number of pulses from the start of measurement 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/full scale)
Instant count: Counts the number of pulses per sampling interval 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/full scale)
Calculation Function Between channels: Addition, subtraction, multiplication, and division for analog input
Statistical: Select two calculations from average, peak, maximum, minimum, RMS
Search Function Search form analog signal levels, values of logic or pulse or alarm point in captured data
Interface to PC Ethernet (10 BASE-T/100 BASE-TX), USB (Hi-speed), WLAN (using B-686 option)
Storage Device Media: SD memory card (support SDHC, up to 32 GB), supports 2 slots*6
Saved contents: Captured data, setting conditions, screen copy
*64 B SD memory card is installed to slot 1 as standard accessory.
Capturing Mode Mode: Normal, Ring, Relay
Ring: Saves most recent data (Number of capturing data: 1000 to 2,000,000 points)*7
Relay: Saves data to multiple files without losing data until data capturing is stopped
*7Size of the capture data will be limited to 1/3 of available memory
Replay Data Replays captured data that was saved in the GL840 (in GB or CVS format)
Scaling (Engineering Unit) Function Measured value can be converted to specified engineering unit
Analog voltage: Converts using two reference points (gain, offset)
Temperature: Converts using two reference points (gain)
Pulse count: Converts using two reference points (gain)
Action During Data Capture Displaying past data (using dual display mode {Current + past data})
Hot-swapping the SD memory card
Saving data in between cursors
Display Size: 7" (177.8 mm) TFT color LCD (WVGA: 800 x 480 dots)
Language: English, French, German, Chinese, Korean, Russian, Spanish, Japanese
Information*8: Waveform in Y-T with digital values, waveform only, digital value, digital values and statistics values
*8Display mode is switched every time the dedicated key is pressed. In magnified digital value mode, the displayed channel number can be specified. In the waveform display mode, the changing of the time scale will be effective from the point of the next displayed data
Operating Environment 32 to 113°F (0 to 45°C), 5 to 85% RH (non condensed), when operating with battery pack 32 to 104°F (0 to 40°), charging battery 59 to 95°F (15 to 35°C)
Power Source AC adapter: 100 to 240 V AC, 50/60 Hz (1 pc of adapter is attached as standard accessory)
DC power: 8.5 to 24 V DC (DC drive cable {option B-514 } is required)
Battery pack: Mountable two battery packs (battery pack {option B-569}: 7.2 V DC, 2900 mAh)
Power Consumption*9 Maximum 38 VA
*9Rating under maximum power consumption using the AC adapter, with LCD display on, and battery pack(s) being charged.
External Dimensions (W x D x H in mm, Excluding Projections) Approximately 9.4 x 6.22 x 2.06" (240 x 158 x 52.5 mm)
Weight*10 Approximately 2.2 lbs (1010 g)
*10Excludes AC adapter and battery pack
Click here for complete specifications on the GRAPHTEC GL840-M

What's included with the GRAPHTEC GL840-M

  • Midi Data Logger
  • Ferrite Core
  • SD Memory Card
  • AC Cable/AC Adapter
  • CD-ROM
  • Quick Start Guide
  • Three-Year Standard Warranty

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL840-M Midi Data Logger, 20 channel, multi-input type.

GRAPHTEC ACADP-20 AC Adapter for the GL220/240/820/840/980/2000 with AC power cable (CE) ACADP-20
Compatible with the GL220, GL240, GL820, GL840, GL980, and GL2000, this AC adapter features a CE-rated AC power cable.




GRAPHTEC B-588 Protective Rubber Holder for the GL840 series B-578
Compatible with the GL840 series, this protective rubber holder is an accessory.




GRAPHTEC B-570 Bracket for DIN Rail for the GL840/GL2000/GL980 B-570
Compatible with the GL840, GL2000, and GL980, this bracket for DIN rail is an accessory.




GRAPHTEC B-540 DIN Rail Bracket for the GLT400/B-566/GL840 B-540
Compatible with the GL840, GLT400, and B-566, this DIN rail bracket is an accessory.




GRAPHTEC B-569 Lithium-ion Battery Pack for the GL840 series and GL240, 7.2 V/2900 mAh B-569
Compatible with the GL840 series and GL240, this lithium-ion battery pack features 7.2 V/2900 mAh.




GRAPHTEC B-568 Wireless LAN Unit for the GL840/GL240/GLT400 B-568
Compatible with the GL840 series, GL240, and GLT400, this wireless LAN unit is a wireless communication option.




GRAPHTEC B-567-20 Extension Cable for the GL840 series, 6.56' B-567-20
Compatible with the GL840 series, this 6.56' (2 m) extension cable is an accessory.




GRAPHTEC B-567-05 Extension Cable for the GL840 series, 19.68" B-567-05
Compatible with the GL840, this 19.68" (50 cm) extension cable is an accessory.




GRAPHTEC B-566 Extension Terminal Base Unit for the GL840 series B-566
Compatible with the GL840 series, this extension terminal base unit allows you to add additional terminals up to 200 channels or 10 terminal blocks. In addition, the original terminal from the main body connects with this terminal base unit.




GRAPHTEC B-564SL Screwless Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564SL
Compatible with the GL840-M and GLT400, this multi-input type screwless terminal block features 20 channels.




GRAPHTEC B-564 Screw Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564
Compatible with the GL840-M and GLT400, this multi-input type screw terminal block features 20 channels.




GRAPHTEC B-514 DC Power Cable for the GL series, 6.56' B-514
Compatible with the GL series 900, 840, 820, 240, and 220, this 6.56' (2 m) power cable is an accessory.




GRAPHTEC DP-581H Thermal Printer for the GL980/GL2000/GL840/GL240 DP-581H
Compatible with the GL980, GL2000, GL840, and GL240, this thermal printer allows you to instantly print out data.




Ask a question about GRAPHTEC GL840-M Midi Data Logger, 20 channel, multi-input type

Customer Reviews for the GRAPHTEC GL840-M

GRAPHTEC GL840-M Offers

Work with reliable and long-term measurements with this data logger that supports large-size SD cards. In addition, this data logger has a flexible input system to suit many applications, smartphone and remote access monitoring, and a maximum sampling interval of up to 10 ms.

Features

  • Multi-channel type
  • Large easy-to-read 7" (177.8 mm) wide color LCD: Carries a clear 7" (177.8 mm) wide TFT color LCD screen (WVGA: 800 x 480 dots) for this data logger, and 4.3" (109.22 mm) wide LCD screen monitoring data are displayed in waveform or digital form option and parameter settings can be displayed on the screen.
  • Expandable up to 200 channels: Standard configuration has 20 analog input channels and it is expandable to 200 channels by adding the optional 20 channel extension terminal base unit B-566 (sold separately) and input terminal unit B-564 (sold separately)
  • Wireless LAN capability, remote monitoring and datalogging
  • Flexible input system for wide array of applications, RTD, T/C
  • Ability to access additional (GL100) sensors and adapters
  • Extended memory capacity using SD memory card
  • Smartphone, remote access monitoring
  • All channel isolated/analog signal input port
  • Logic/pulse signal input port
  • USB2.0
  • Ethernet (10BASE-T/100BASE-TX)
  • SD card slot for SDHC memory card
  • Support digital sensors: Digital sensors and input terminal/adapters for the GL100 connects to this data logger directly
  • Easy operation with control button
  • Three types of input systems enable measurement of various signals: Along with the basic analog signal, logic/pulse, and digital sensors can be all connected to monitor a variety of measurements
  • Control settings
  • Maximum sampling interval of up to 10 ms: Provides faster sampling rates for voltage measurements and you are able to achieve up to 10 ms sampling speed when limiting the number of channels in use.
  • Alarm output function: Based on set conditions for each channels, alarm signals can be placed using the four channel alarm output ports (*Input/output cable B-513 option {sold seperately} is required to connect the alarm output ports to external buzzer/light mechanism)
  • Navigation feature: Simple to use navigation screen allows setting operation for measurement and wireless LAN adapter (sold separately)
  • Ring capture function: The most recent data is saved when the memory is configured in ring memory mode (Number of capturing data is 1000 to 2,000,000 points)
  • Relay capture function: Data is continuously saved to multiple files up to 2 GB without losing any data until capturing is stopped when the memory is configured in the relay mode
  • Hot-swapping the SD memory card: SD card can be replaced during data capturing when the sampling interval is 100 ms or slower
  • USB drive mode: USB drive mode function enables data to be transferred to the PC from this data logger by drag and drop feature

Input

  • Adoption of a pluggable M3 screw type input terminal facilitates wiring
  • 20 channel measurements are supported by the standard terminal, and 200 channel measurements are supported by the extension terminal base
  • When using the GS series and terminal/adapter, the acceleration, AC current, CO2, and illuminance/ultraviolet measurements are also possible
  • Because that standard terminal has a whole CH isolated, the different standard signals can be measured at the same time

Display and operation

  • With this data loggers high-resolution 7" (177.8 mm) TFT color liquid crystal display, you can confirm the waveforms of measured data and each channel's settings at a glance
  • Easy operation is achieved through a straightforward menu structure and key allocation which resembles mobile phones

Data capture

  • Data is directly saved to the large SD memory card (Standard accessory: 4 GB)
  • Their two mounting slots for the SD memory card and long-term measurement can be performed while backing up the data (*When the optional wireless LAN unit {sold separately} is installed, the SD memory card cannot be inserted into the SD CARD2 slot)
  • Because disk image can be used for the SD memory card , multiple data can be saved
  • The new ring memory capture function maintains latest data even after capturing for a long term (You need to set how long you want to keep data)
  • For voltage, temperature and humidity measurements, data can be captured at sampling rates of up to 10 msec per channel by using fewer measuring channels (Temperature measurement can be done at sampling rates of 100 msec and higher)
  • This data logger is equipped with the relay recording function, and 2 GB or more data can be saved by switching the to the other file without data missing (When the capacity of one file reaches 2 GB, the file is switched)

Data control and processing

  • The application software provided lets you set conditions and monitor data on a PC
  • The USB drive mode function enables the SD memory card to be recognized as an external drive by the PC (Connect this data logger to the PC and turn on the data logger power while holding down the {START} key)
  • The WEB server function enables control and monitoring from a remote location without using dedicated software
  • The FTP client function enables backup of measurement data to the FTP server
  • The NTP client function enables synchronization of the time with the NTP server
  • When optional wireless LAN unit is installed (sold separately), the data capture can be performed remotely by controlling the GL100-WL

Networking features

  • Web and FTP server function: This data logger can be controlled externally via a network on the WEB browser, which also supports monitoring and transfer of signals and captured data
  • FTP client function: Captured data is periodically transferred to the FTP server for backup
  • NTP client function: The clock on this data logger is periodically synchronized with the NPT server (This data logger needs to be connected to a LAN environment using the available Ethernet/WLAN ports)

The GL series carries two SD memory card slots for storage device. The SDHC type SD memory card is supported up to 32 GB. 4 GB SD memory card comes as a standard accessory installed in the first slot.

Accommodates a wide variety of measurements

Multifunction analog input ports: Contains a highly isolated input mechanism which ensures that signals are not corrupted by noise from other channels. This data loggers inputs are suitable for combined measurements from voltage, temperature, humidity, logic, and pulse signals.
Four channels if logic/pulse inputs: Supports four-channel logic or pulse signal inputs. Pulse mode allows cumulative, instant, or rotational values for industrial measurements capability with speed and flow.

Applications

  • Agriculture
  • Greenhouse and hydroponics
  • Construction and civil engineering
  • Machinery manufacturing
  • Automotive
  • Aerospace
  • Utilities/gas and electric
  • Electrical appliance and office equipment
  • Food processing

High performance software with useful functions for the PC

Supports GL840, GL240, GL100

Up to 10 units of GL840, GL240 and GL100 can be connected to one PC simultaneously. Up to 1000 channels are supported.

Various measurement screen

Display data in Y-T waveform, digital monitoring, statistical calculation result. The direct-Excel function enables captured data to be written directly to an Excel file.

File operation

Data capture in multiple files can be merged into a single file. Using the combine function, data can be imported as a new channel overlaying on top of each other. The bind function connects the data in a time axis. When using the relay capture mode, the bind feature will append multiple files together into one large, continuous file.

Useful functions

Scheduling function: Create a schedule for your monitoring to start and stop at selected time, and set an automatic measurement schedule.
Group function: Multiple units can be managed, such as controlling start or stop simultaneously. Data captured by each unit is saved in a single file.

Data format conversion

Converts the GBD (Graphtec Binary Data) format to CSV format. The file size is reduced using the compression function saving a value at particular time point of a specified interval. Or, it will save the average, maximum, or minimum values from the specified time intervals as the highlighted values.

High quality performance and measurement software with useful functions for the PC and smart device environment

For PC

  • Software for the PC is included as a standard accessory
  • Monitor and save captured data remotely
  • Control this data logger
  • Scheduling function
  • Group function
  • Data format conversion
  • File operation and more!

For smart device (GL-connect)

Apps for the smart devices are available on the Android OS and iOS platforms. Download them free from the individual stores.

Monitoring captured data: Real time captured data can be displayed as digital values in real time on the smart devices apps. The saved data on this data loggers main body can also be displayed in waveform display format (Captured data will not be saved on the smart device).

Set and control simple functions: Dedicated control features allow remote start and stop, setting the sampling interval, and setting the alarm conditions.

Control the settings remotely: Web server functions for this data logger allows remote control and monitoring using this application.

GRAPHTEC GL840-M Specifications

Number of Analog Input Channels: 20 channels in standard configuration, expandable up to 200 channels
Terminals: Up to 10 terminals (20 channels/terminals), standard configuration: 1
Type of Analog Input Terminal Multi-input type
Port for Digital Sensor 1 port for the sensor/input terminal/adapter of the GL100
External Input/Output*1 Input*2: Trigger or sampling (1 channel), logic/pulse (4 channels)
Output*3: Alarm (4 channels)
*1Input/output cable for GL (option B-513 is required to connect the signal.
*2Input signal:
Voltage range: Up to 24 V (common ground)
Signal type: Voltage, open collector, contact (relay)
Threshold: Approximately + 2.5 V (Hysteresis: Approximately 0.5 V (2.5 to 3 V)

*3Output signal: Open collector (pull-up to 5 V by 10 kΩ resistor)
Maximum rating of the output transistor
Voltage: Maximum 30 V
Current: Maximum 0.5 A
Collector dissipation: Maximum 0.2 W
Sampling Interval 10 ms to 1 hour (10 to 50 ms: voltage only)*4, external signal
*4Minimum interval varies by number of channels used.
Time Scale of Waveform Display 1 second to 24 hour/division
Trigger, Alarm Function Trigger action: Start or stop capturing data by the trigger

Repeat action: Off, On (auto rearmed)

Trigger source:
Start: Off, Measured signal, Alarm, External, Clock, Week or Time
Stop: Off, Measured signal, Alarm, External, Clock, Week or Time

Condition setting:
Combination: OR or AND
Analog signal: Rising (High), Falling (Low), Window-in, Window-out
Logic signal: Pattern (combination of each input signal in high or low)
Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out

Alarm output: Outputs a signal when alarm condition occurs in the input signal*5
*5Output port can be specified in each input channel.
Pulse Input Function Rotation count (RPM): Counts the number of pulses per sampling interval and converts to rpm (rotations per minutes), number of pulses for one rotation may be set to 50, 500, 5000, 50k, 500k, 5M, 50M, 500M rpm/F.S (rpm./full scale)
Accumulating count: Accumulates the number of pulses from the start of measurement 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/full scale)
Instant count: Counts the number of pulses per sampling interval 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/full scale)
Calculation Function Between channels: Addition, subtraction, multiplication, and division for analog input
Statistical: Select two calculations from average, peak, maximum, minimum, RMS
Search Function Search form analog signal levels, values of logic or pulse or alarm point in captured data
Interface to PC Ethernet (10 BASE-T/100 BASE-TX), USB (Hi-speed), WLAN (using B-686 option)
Storage Device Media: SD memory card (support SDHC, up to 32 GB), supports 2 slots*6
Saved contents: Captured data, setting conditions, screen copy
*64 B SD memory card is installed to slot 1 as standard accessory.
Capturing Mode Mode: Normal, Ring, Relay
Ring: Saves most recent data (Number of capturing data: 1000 to 2,000,000 points)*7
Relay: Saves data to multiple files without losing data until data capturing is stopped
*7Size of the capture data will be limited to 1/3 of available memory
Replay Data Replays captured data that was saved in the GL840 (in GB or CVS format)
Scaling (Engineering Unit) Function Measured value can be converted to specified engineering unit
Analog voltage: Converts using two reference points (gain, offset)
Temperature: Converts using two reference points (gain)
Pulse count: Converts using two reference points (gain)
Action During Data Capture Displaying past data (using dual display mode {Current + past data})
Hot-swapping the SD memory card
Saving data in between cursors
Display Size: 7" (177.8 mm) TFT color LCD (WVGA: 800 x 480 dots)
Language: English, French, German, Chinese, Korean, Russian, Spanish, Japanese
Information*8: Waveform in Y-T with digital values, waveform only, digital value, digital values and statistics values
*8Display mode is switched every time the dedicated key is pressed. In magnified digital value mode, the displayed channel number can be specified. In the waveform display mode, the changing of the time scale will be effective from the point of the next displayed data
Operating Environment 32 to 113°F (0 to 45°C), 5 to 85% RH (non condensed), when operating with battery pack 32 to 104°F (0 to 40°), charging battery 59 to 95°F (15 to 35°C)
Power Source AC adapter: 100 to 240 V AC, 50/60 Hz (1 pc of adapter is attached as standard accessory)
DC power: 8.5 to 24 V DC (DC drive cable {option B-514 } is required)
Battery pack: Mountable two battery packs (battery pack {option B-569}: 7.2 V DC, 2900 mAh)
Power Consumption*9 Maximum 38 VA
*9Rating under maximum power consumption using the AC adapter, with LCD display on, and battery pack(s) being charged.
External Dimensions (W x D x H in mm, Excluding Projections) Approximately 9.4 x 6.22 x 2.06" (240 x 158 x 52.5 mm)
Weight*10 Approximately 2.2 lbs (1010 g)
*10Excludes AC adapter and battery pack
Click here for complete specifications on the GRAPHTEC GL840-M

What's included with the GRAPHTEC GL840-M

  • Midi Data Logger
  • Ferrite Core
  • SD Memory Card
  • AC Cable/AC Adapter
  • CD-ROM
  • Quick Start Guide
  • Three-Year Standard Warranty

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL840-M Midi Data Logger, 20 channel, multi-input type.

GRAPHTEC ACADP-20 AC Adapter for the GL220/240/820/840/980/2000 with AC power cable (CE) ACADP-20
Compatible with the GL220, GL240, GL820, GL840, GL980, and GL2000, this AC adapter features a CE-rated AC power cable.




GRAPHTEC B-588 Protective Rubber Holder for the GL840 series B-578
Compatible with the GL840 series, this protective rubber holder is an accessory.




GRAPHTEC B-570 Bracket for DIN Rail for the GL840/GL2000/GL980 B-570
Compatible with the GL840, GL2000, and GL980, this bracket for DIN rail is an accessory.




GRAPHTEC B-540 DIN Rail Bracket for the GLT400/B-566/GL840 B-540
Compatible with the GL840, GLT400, and B-566, this DIN rail bracket is an accessory.




GRAPHTEC B-569 Lithium-ion Battery Pack for the GL840 series and GL240, 7.2 V/2900 mAh B-569
Compatible with the GL840 series and GL240, this lithium-ion battery pack features 7.2 V/2900 mAh.




GRAPHTEC B-568 Wireless LAN Unit for the GL840/GL240/GLT400 B-568
Compatible with the GL840 series, GL240, and GLT400, this wireless LAN unit is a wireless communication option.




GRAPHTEC B-567-20 Extension Cable for the GL840 series, 6.56' B-567-20
Compatible with the GL840 series, this 6.56' (2 m) extension cable is an accessory.




GRAPHTEC B-567-05 Extension Cable for the GL840 series, 19.68" B-567-05
Compatible with the GL840, this 19.68" (50 cm) extension cable is an accessory.




GRAPHTEC B-566 Extension Terminal Base Unit for the GL840 series B-566
Compatible with the GL840 series, this extension terminal base unit allows you to add additional terminals up to 200 channels or 10 terminal blocks. In addition, the original terminal from the main body connects with this terminal base unit.




GRAPHTEC B-564SL Screwless Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564SL
Compatible with the GL840-M and GLT400, this multi-input type screwless terminal block features 20 channels.




GRAPHTEC B-564 Screw Input Terminal Block for the GL840-M and GLT400, 20 channels, multi-input type B-564
Compatible with the GL840-M and GLT400, this multi-input type screw terminal block features 20 channels.




GRAPHTEC B-514 DC Power Cable for the GL series, 6.56' B-514
Compatible with the GL series 900, 840, 820, 240, and 220, this 6.56' (2 m) power cable is an accessory.




GRAPHTEC DP-581H Thermal Printer for the GL980/GL2000/GL840/GL240 DP-581H
Compatible with the GL980, GL2000, GL840, and GL240, this thermal printer allows you to instantly print out data.




Ask a question about GRAPHTEC GL840-M Midi Data Logger, 20 channel, multi-input type

Customer Reviews for the GRAPHTEC GL840-M

More GRAPHTEC Products

Calibration Lab