Suitable for high-performance applications, this folding analog multimeter works with 46 measuring ranges of up to 600 V for direct and alternating voltages. Work with outstanding protection with this rugged multimeter that can handle mechanical stress and works in RMS values.
Suitable for high-performance applications, this folding analog multimeter works with 46 measuring ranges of up to 600 V for direct and alternating voltages. Work with outstanding protection with this rugged multimeter that can handle mechanical stress and works in RMS values.
Features
Applications
Measuring Ranges | Voltage: 100 mV, 300 mV, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V and 600 V Alternating voltage levels: -40 to 62 dB Current: 10 µA, 100 µA, 1mA, 10 mA, 100 mA, 1 A and 10 A Resistance: 1 Ω to 2 kΩ, 10 Ω to 20 kΩ, 100 Ω to 200 kΩ, 1 kΩ to 2 MΩ, 10 kΩ to 20 MΩ |
Overload Protection | 600 V≂ |
Postition | Normal use: Instrument and scale horizontal ±1° Additional influence error of maximum ±1% of the scale length if the scale is tilted between 0 and ±120° relative to horizontal |
Frequency | Additional influence error of maximum ±5% of full scale value in the following ranges: 100 mV, 3 to 600 V: 15 Hz to 1 kHz 10 μA to 10 A: 15 Hz to 1 kHz 300 mV, 1 V: 15 to 200 Hz |
Auxiliary voltage | No additional influence error. The upper limit must be set with the potentiometer for all measuring ranges in the case of resistance measurement |
Temperature | 41 to 73.4 to 95°F (5 to 23 to 35°C) Ambient: 73.4°F (23°C) ±2 K Limits: Accuracy: 41 to 95°F (5 to 35°C) Operation: 32 to 104°F (0 to 40°C) Storage: -13 to 149°F (-25 to 65°C), without batteries |
Relative Humidity | 40 to 60% |
Measured Quantity | Frequency: 45 to 65 Hz Waveshape: Sine |
Fuses | Ranges to 1 A and Ω: FF 1.6 A / 600 V, 0.23 x 1.26" (6 x 32 mm) in combination with rectifier diodes for the
10 μA to 1 A and Ω x1 to kΩ x10 ranges, switching capacity: 50 kA at 600 V~ 10 A range: FF 16 A / 600 V AC, 0.23 x 1.26" (6 x 32 mm), switching capacity: 50 kA at 600 V~ |
Common Mode Interference Voltage Damping | >120 dB, DC and 50 Hz AC |
Interference | Emission: EN 61326:2006 class B Immunity: EN 61326-1: 2006 and EN 61326-2-1: 2006 |
Battery | Voltage: 7.5 V ±0.1 V Operation: Nominal voltage: 9 V- , 9 V flat cell battery per IEC 6LR61 (6F22), alkaline manganese or NiMH rechargeable battery Service life: With alkaline manganese: approximately 1000 hours, with NiCd: approximately 200 hours, in the Ω x 1 range: ¼ of specified service life Test: Pointer must be within the battery test field |
Protection | Housing: IP 40 Connector jacks: IP 20 |
Dimensions | 5.7 x 4.6 x 1.7" (146 x 118 x 44 mm), folded closed |
Weight | Approximately 0.99 lbs (45 kg) |
Click on a category to view a selection of compatible accessories with the Gossen Metrawatt M113A METRAport 3A Folding Analog Multimeter for High Performance Applications.
Measuring Ranges | Voltage: 100 mV, 300 mV, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V and 600 V Alternating voltage levels: -40 to 62 dB Current: 10 µA, 100 µA, 1mA, 10 mA, 100 mA, 1 A and 10 A Resistance: 1 Ω to 2 kΩ, 10 Ω to 20 kΩ, 100 Ω to 200 kΩ, 1 kΩ to 2 MΩ, 10 kΩ to 20 MΩ |
Overload Protection | 600 V≂ |
Postition | Normal use: Instrument and scale horizontal ±1° Additional influence error of maximum ±1% of the scale length if the scale is tilted between 0 and ±120° relative to horizontal |
Frequency | Additional influence error of maximum ±5% of full scale value in the following ranges: 100 mV, 3 to 600 V: 15 Hz to 1 kHz 10 μA to 10 A: 15 Hz to 1 kHz 300 mV, 1 V: 15 to 200 Hz |
Auxiliary voltage | No additional influence error. The upper limit must be set with the potentiometer for all measuring ranges in the case of resistance measurement |
Temperature | 41 to 73.4 to 95°F (5 to 23 to 35°C) Ambient: 73.4°F (23°C) ±2 K Limits: Accuracy: 41 to 95°F (5 to 35°C) Operation: 32 to 104°F (0 to 40°C) Storage: -13 to 149°F (-25 to 65°C), without batteries |
Relative Humidity | 40 to 60% |
Measured Quantity | Frequency: 45 to 65 Hz Waveshape: Sine |
Fuses | Ranges to 1 A and Ω: FF 1.6 A / 600 V, 0.23 x 1.26" (6 x 32 mm) in combination with rectifier diodes for the
10 μA to 1 A and Ω x1 to kΩ x10 ranges, switching capacity: 50 kA at 600 V~ 10 A range: FF 16 A / 600 V AC, 0.23 x 1.26" (6 x 32 mm), switching capacity: 50 kA at 600 V~ |
Common Mode Interference Voltage Damping | >120 dB, DC and 50 Hz AC |
Interference | Emission: EN 61326:2006 class B Immunity: EN 61326-1: 2006 and EN 61326-2-1: 2006 |
Battery | Voltage: 7.5 V ±0.1 V Operation: Nominal voltage: 9 V- , 9 V flat cell battery per IEC 6LR61 (6F22), alkaline manganese or NiMH rechargeable battery Service life: With alkaline manganese: approximately 1000 hours, with NiCd: approximately 200 hours, in the Ω x 1 range: ¼ of specified service life Test: Pointer must be within the battery test field |
Protection | Housing: IP 40 Connector jacks: IP 20 |
Dimensions | 5.7 x 4.6 x 1.7" (146 x 118 x 44 mm), folded closed |
Weight | Approximately 0.99 lbs (45 kg) |
Click on a category to view a selection of compatible accessories with the Gossen Metrawatt M113A METRAport 3A Folding Analog Multimeter for High Performance Applications.