Fluke Norma 6003 Portable Power Analyzer, 3-channel

Model: NORMA 6003 | UPC: 095969918718

Fluke Norma 6003 Portable Power Analyzer, 3-channel

Model: NORMA 6003 | UPC: 095969918718

Gives you the freedom to make high accuracy power measurements, this battery-powered analyzer is designed for portability and allows you to make measurements directly at the load, in nearly any environment. Includes three measurement channels, where each consists of a voltage and current input, which is ideal for three-phase power measurements.

Gives you the freedom to make high accuracy power measurements, this battery-powered analyzer is designed for portability and allows you to make measurements directly at the load, in nearly any environment. Includes three measurement channels, where each consists of a voltage and current input, which is ideal for three-phase power measurements.

Your Price $16764.99 USD
Availability 11 to 12 Weeks
Quantity

Fluke NORMA 6003 Offers

Accurate enough for the lab, built for the field

Designed for portability, the lightweight, battery-powered analyzer eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.

Combined with wide-band frequency response, it makes it easier than ever to make measurements on hard to access systems such as inverter drive systems, DC-AC and AC-DC power conversion systems, and electric motors without removing them from service. Making these measurements in the field simplifies the troubleshooting, and performance measurement processes without sacrificing uptime, giving you more accurate test results, that will enable you to discover whether your loads are operating as effectively and efficiently as they should be.

Features

  • Key measurements: Voltage, current, active power, reactive power, apparent power, power factor, and harmonics with associated values
  • High accuracy and wide bandwidth - 0.1% measurement accuracy and 500 kHz bandwidth
  • Highly portable and easily installed in tight spaces - only 3.78" (9.6 cm) thick
  • Operate continuously for up to 10 hours without an external power supply using the 5000 mAh Li-ion internal battery
  • Measure safely - safety rated for CAT III 1000V, CAT IV 600 V environments
  • Measure three phase power and DC output power at the same time with three channels, with voltage and current inputs on each channel
  • 0.1% accuracy, 500 kHz bandwidth, 200 ks/s sample rate so you can rely on the power conversion system measurements you take no matter what distortion may be present
  • USB and RS485 interface and open communication protocol for easy system integration and software platform flexibility
  • Combine two analyzers to enable simultaneous measurement of multiple circuits for even more troubleshooting capability - configurable to 6 or 8 channels using dual analyzer synchronization
  • View critical data in the field on the main display - Meter, Waveform, Harmonics up to the 100th, Vector and Trend
  • Ensure high common-mode rejection and allow flexible configurations according to measurement requirements using the electrically isolated channels
  • User adjustable measurement rate from 100 ms to 1 s with continuous logging via 32GB of onboard storage
  • Easy in-field set up using the integrated front panel or a remote PC connection (USB or RS485)
  • Online measuring, data download and analysis with included PC software (Fluke Power Analyzer Software)
  • Full remote control of the connected instrument using Fluke Power Analyzer Software and a local USB or long-distance RS485 connection

Applications

  • R&D and third party labs
  • Renewable energy/clean tech
  • Manufacturing

Fluke NORMA 6003 Specifications

Key Specifications
Inputs 3 Voltage + 3 Current
Sample Rate 200 ks/s
Measurement Update Rate 100 ms, 200 ms, 500 ms, 1s
Dual Analyzer Synchronization Mode Able to extend to 6, 7 or 8 channels (using multiple instruments)
Data Trend Storage Rate As per display rate
Main Function Meter, Scope, Harmonic, Phasor, Trend
Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency
Electrical
Range 10, 100, 1000 V
Crest Factor CF ≤2
Maximum Voltage 10% overload
Input Impedance 2 MΩ/10 pF (typical)
Temperature Coefficient 0.05 (Spec)/k
Bandwidth 1000 V range: 500 kHz
100 V range: 200 kHz
10 V range:100 kHz
CMRR 120 dB at 50/60 Hz
Accuracy (% Reading + % Range)
Range - 1000 V DC: 0.1 + 0.1
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 0.5
Range - 100 V DC: 0.1 + 0.1
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 0.5
Range - 10 V DC: 0.1 + 0.2
AC (10 Hz to 1 kHz): 0.1 + 0.2
AC (10 kHz): 5 + 0.5
Current Crest factor: CF ≤2
Temperature coefficient: 0.05 x (Spec)/k
Overload capacity: 10% overload
CMRR: 120 dB at 50/60 Hz
Shunt (Current Input) Measuring range: 0.1, 1, 10 A
Input impedance: 0.025 Ω (typical)
Bandwidth: 10 A - 500 kHz; 1 A - 200 kHz; 0.1 A - 100 kHz
BNC (Voltage Input) Range: 0.1, 1, 10 V
Input impedance: 100 kΩ/100 pF (typical)
Bandwidth: 10 V - 500 kHz; 1 V - 200 kHz; 0.1 V - 100 kHz
Range - 10 A DC: 0.1 + 0.2
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 1
Range - 1 A DC: 0.1 + 0.5
AC (10 Hz to 1 kHz): 0.1 + 0.2
AC (10 kHz): 5 + 1
Range - 0.1 A DC: 0.1 + 2
AC (10 Hz to 1 kHz): 0.1 + 1
AC (10 kHz): 5 + 1
Range - 10 V DC: 0.1 + 0.1
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 1
Range - 1 V DC: 0.1 + 0.2
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 1
Range - 0.1 V DC: 0.1 + 1
AC (10 Hz to 1 kHz): 0.1 + 0.5
AC (10 kHz): 5 + 1
General Specifications
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C)
Operating Humidity Non-condensing (<50°F [10°C])
≤90% RH (at 50 to 86°F [10 to 30°C])
≤75% RH (at 86 to 104°F [30 to 40°C])
≤45% RH (at 104 to 122°F [40 to 50°C])
Altitude Operating: 6561.68' (2000 m)
Storage: 39,370.1' (12,000 m)
Display 5.7", TFT LCD, 640 x 480
Battery BP 291, 10.8 V/5000 mAh, 54Wh IEC 62133, UN38.3
Operating time: 10 Hours (on battery)
Communication Interface USB/RS485
Storage Capacity 32GB
PC Software Fluke Power Analyzer software
Ingress Protection IP 50 (Terminals mated) according to IEC 60529
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
EMC IEC 61326-1: Industrial
IEC 61326-2-2
Dimensions 11.73 x 8.46 x 3.78" (298 x 215 x 96 mm)
Weight 7.7 lbs (3.5 kg)
Click here for complete specifications on the Fluke NORMA 6003

What's included with the Fluke NORMA 6003

  • Power Analyzer
  • Test Leads:
    • 3 x Red
    • 3 x Black
    • 6 x Blue
  • Alligator Clips:
    • 3 x Red
    • 3 x Black
    • 6 x Blue
  • USB (Mini B) Cable
  • RS-485/Synchrony Adapter
  • Soft Carrying Case
  • Power Supply Adapter
  • Power Cord
  • USB Flash Drive for PC SW and User Manual

Webinar: Electrical Power Testing


It’s no secret that power quality can have a big impact on productivity and safety in the workplace. That’s why there’s been a rapid increase in the demand for electrical power measurement equipment recently. With that in mind, having an effective frontline troubleshooting and reliability tactic should be a priority. Keeping track of the power quality in your facility plays an important part in avoiding costs related to poor power quality management like productivity costs, reduced efficiency, higher energy bills, and capital equipment degradation and failure.

Webinar: Introduction to Portable Precision Power Analyzers with Fluke


This wideband precision analyzer is accurate enough for the lab, yet it's built for the field. Offering you more freedom than ever before to make high accuracy power measurements wherever you need to. Whether in the lab or in the field. Designed for portability and eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.

Click on a category to view a selection of compatible accessories with the Fluke Norma 6003 Portable Power Analyzer, 3-channel.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke 80i-2010s AC/DC Current Clamp, 2000 A 80i-2010s
An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also safety rated for CAT III 1000 V, CAT IV 600 V environments.




Fluke 80i-2010s/3PK AC/DC Current Clamp, 2000 A, 3-pack 80i-2010s/3PK
An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also safety rated for CAT III 1000 V, CAT IV 600 V environments.




Fluke U1500S High Voltage Differential Probe, 1500 V U1500S
Built for accuracy and portability, this sensor allows for safe connections to DC bus bars up to 1.5 kV as well as instrument voltage inputs. With a measurement range of 1500 V and an accuracy of 0.1%, the voltage can be scaled in the instrument to provide results in real units.




Ask a question about Fluke Norma 6003 Portable Power Analyzer, 3-channel

Customer Reviews for the Fluke NORMA 6003

Fluke NORMA 6003 Offers

Accurate enough for the lab, built for the field

Designed for portability, the lightweight, battery-powered analyzer eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.

Combined with wide-band frequency response, it makes it easier than ever to make measurements on hard to access systems such as inverter drive systems, DC-AC and AC-DC power conversion systems, and electric motors without removing them from service. Making these measurements in the field simplifies the troubleshooting, and performance measurement processes without sacrificing uptime, giving you more accurate test results, that will enable you to discover whether your loads are operating as effectively and efficiently as they should be.

Features

  • Key measurements: Voltage, current, active power, reactive power, apparent power, power factor, and harmonics with associated values
  • High accuracy and wide bandwidth - 0.1% measurement accuracy and 500 kHz bandwidth
  • Highly portable and easily installed in tight spaces - only 3.78" (9.6 cm) thick
  • Operate continuously for up to 10 hours without an external power supply using the 5000 mAh Li-ion internal battery
  • Measure safely - safety rated for CAT III 1000V, CAT IV 600 V environments
  • Measure three phase power and DC output power at the same time with three channels, with voltage and current inputs on each channel
  • 0.1% accuracy, 500 kHz bandwidth, 200 ks/s sample rate so you can rely on the power conversion system measurements you take no matter what distortion may be present
  • USB and RS485 interface and open communication protocol for easy system integration and software platform flexibility
  • Combine two analyzers to enable simultaneous measurement of multiple circuits for even more troubleshooting capability - configurable to 6 or 8 channels using dual analyzer synchronization
  • View critical data in the field on the main display - Meter, Waveform, Harmonics up to the 100th, Vector and Trend
  • Ensure high common-mode rejection and allow flexible configurations according to measurement requirements using the electrically isolated channels
  • User adjustable measurement rate from 100 ms to 1 s with continuous logging via 32GB of onboard storage
  • Easy in-field set up using the integrated front panel or a remote PC connection (USB or RS485)
  • Online measuring, data download and analysis with included PC software (Fluke Power Analyzer Software)
  • Full remote control of the connected instrument using Fluke Power Analyzer Software and a local USB or long-distance RS485 connection

Applications

  • R&D and third party labs
  • Renewable energy/clean tech
  • Manufacturing

Fluke NORMA 6003 Specifications

Key Specifications
Inputs 3 Voltage + 3 Current
Sample Rate 200 ks/s
Measurement Update Rate 100 ms, 200 ms, 500 ms, 1s
Dual Analyzer Synchronization Mode Able to extend to 6, 7 or 8 channels (using multiple instruments)
Data Trend Storage Rate As per display rate
Main Function Meter, Scope, Harmonic, Phasor, Trend
Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency
Electrical
Range 10, 100, 1000 V
Crest Factor CF ≤2
Maximum Voltage 10% overload
Input Impedance 2 MΩ/10 pF (typical)
Temperature Coefficient 0.05 (Spec)/k
Bandwidth 1000 V range: 500 kHz
100 V range: 200 kHz
10 V range:100 kHz
CMRR 120 dB at 50/60 Hz
Accuracy (% Reading + % Range)
Range - 1000 V DC: 0.1 + 0.1
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 0.5
Range - 100 V DC: 0.1 + 0.1
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 0.5
Range - 10 V DC: 0.1 + 0.2
AC (10 Hz to 1 kHz): 0.1 + 0.2
AC (10 kHz): 5 + 0.5
Current Crest factor: CF ≤2
Temperature coefficient: 0.05 x (Spec)/k
Overload capacity: 10% overload
CMRR: 120 dB at 50/60 Hz
Shunt (Current Input) Measuring range: 0.1, 1, 10 A
Input impedance: 0.025 Ω (typical)
Bandwidth: 10 A - 500 kHz; 1 A - 200 kHz; 0.1 A - 100 kHz
BNC (Voltage Input) Range: 0.1, 1, 10 V
Input impedance: 100 kΩ/100 pF (typical)
Bandwidth: 10 V - 500 kHz; 1 V - 200 kHz; 0.1 V - 100 kHz
Range - 10 A DC: 0.1 + 0.2
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 1
Range - 1 A DC: 0.1 + 0.5
AC (10 Hz to 1 kHz): 0.1 + 0.2
AC (10 kHz): 5 + 1
Range - 0.1 A DC: 0.1 + 2
AC (10 Hz to 1 kHz): 0.1 + 1
AC (10 kHz): 5 + 1
Range - 10 V DC: 0.1 + 0.1
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 1
Range - 1 V DC: 0.1 + 0.2
AC (10 Hz to 1 kHz): 0.1 + 0.1
AC (10 kHz): 5 + 1
Range - 0.1 V DC: 0.1 + 1
AC (10 Hz to 1 kHz): 0.1 + 0.5
AC (10 kHz): 5 + 1
General Specifications
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C)
Operating Humidity Non-condensing (<50°F [10°C])
≤90% RH (at 50 to 86°F [10 to 30°C])
≤75% RH (at 86 to 104°F [30 to 40°C])
≤45% RH (at 104 to 122°F [40 to 50°C])
Altitude Operating: 6561.68' (2000 m)
Storage: 39,370.1' (12,000 m)
Display 5.7", TFT LCD, 640 x 480
Battery BP 291, 10.8 V/5000 mAh, 54Wh IEC 62133, UN38.3
Operating time: 10 Hours (on battery)
Communication Interface USB/RS485
Storage Capacity 32GB
PC Software Fluke Power Analyzer software
Ingress Protection IP 50 (Terminals mated) according to IEC 60529
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
EMC IEC 61326-1: Industrial
IEC 61326-2-2
Dimensions 11.73 x 8.46 x 3.78" (298 x 215 x 96 mm)
Weight 7.7 lbs (3.5 kg)
Click here for complete specifications on the Fluke NORMA 6003

What's included with the Fluke NORMA 6003

  • Power Analyzer
  • Test Leads:
    • 3 x Red
    • 3 x Black
    • 6 x Blue
  • Alligator Clips:
    • 3 x Red
    • 3 x Black
    • 6 x Blue
  • USB (Mini B) Cable
  • RS-485/Synchrony Adapter
  • Soft Carrying Case
  • Power Supply Adapter
  • Power Cord
  • USB Flash Drive for PC SW and User Manual

Webinar: Electrical Power Testing


It’s no secret that power quality can have a big impact on productivity and safety in the workplace. That’s why there’s been a rapid increase in the demand for electrical power measurement equipment recently. With that in mind, having an effective frontline troubleshooting and reliability tactic should be a priority. Keeping track of the power quality in your facility plays an important part in avoiding costs related to poor power quality management like productivity costs, reduced efficiency, higher energy bills, and capital equipment degradation and failure.

Webinar: Introduction to Portable Precision Power Analyzers with Fluke


This wideband precision analyzer is accurate enough for the lab, yet it's built for the field. Offering you more freedom than ever before to make high accuracy power measurements wherever you need to. Whether in the lab or in the field. Designed for portability and eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.

Click on a category to view a selection of compatible accessories with the Fluke Norma 6003 Portable Power Analyzer, 3-channel.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke 80i-2010s AC/DC Current Clamp, 2000 A 80i-2010s
An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also safety rated for CAT III 1000 V, CAT IV 600 V environments.




Fluke 80i-2010s/3PK AC/DC Current Clamp, 2000 A, 3-pack 80i-2010s/3PK
An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also safety rated for CAT III 1000 V, CAT IV 600 V environments.




Fluke U1500S High Voltage Differential Probe, 1500 V U1500S
Built for accuracy and portability, this sensor allows for safe connections to DC bus bars up to 1.5 kV as well as instrument voltage inputs. With a measurement range of 1500 V and an accuracy of 0.1%, the voltage can be scaled in the instrument to provide results in real units.




Ask a question about Fluke Norma 6003 Portable Power Analyzer, 3-channel

Customer Reviews for the Fluke NORMA 6003

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab