Fluke Networks DSX2-8000QOI 2GHZ DSX Quad OTDR OLTS INSPC

Model: DSX2-8000QOI | UPC: 754082143710

Fluke Networks DSX2-8000QOI 2GHZ DSX Quad OTDR OLTS INSPC

Model: DSX2-8000QOI | UPC: 754082143710

The DSX-8000QOI INT CableAnalyzer with Quad OLTS, Quad OTDR and fiber inspection accelerates every step of the copper certification process. This is the non-wireless version and is available for countries where the WiFi adapter is not certified or for customers who do not wish to receive the WiFi adapter.

The DSX-8000QOI INT CableAnalyzer with Quad OLTS, Quad OTDR and fiber inspection accelerates every step of the copper certification process. This is the non-wireless version and is available for countries where the WiFi adapter is not certified or for customers who do not wish to receive the WiFi adapter.

Sale Price $38922.44 USD
Regular Price $40970.99 USD
Availability 3 to 4 Weeks
Quantity

Fluke Networks DSX2-8000QOI Offers

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provide accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements and the difference between being profitable or not can be just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy (making jobs easier to manage), and getting to system acceptance faster. It's not just for the expert technicians and project managers, individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Features

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  • ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Fluke Networks DSX2-8000QOI Specifications

Copper Certifications
Category 6A / Class EA Test Time 8 Seconds
Category 8 / Class I/II Test Time 15 Seconds
HDTDX/HDTDR Diagnostic Test Times ~3 Seconds
Internal Memory ~5,000 Cat 8 with plots
~12,000 Cat 6A with plots
Level V Accuracy 1 GHz
2G Accuracy 2 GHz
Resistance Unbalance Measurement Yes
Shield Integrity Check Yes
TCL Measurement Yes
ELTCTL Measurement Yes
CDNEXT Measurement Yes
CMRL Measurement Yes
Built in Alien XTalk Module Yes
Channel Adapter 2 GHz Range
Permanent Link Adapter 2 GHz Range
Environmental
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -22°F to 140°F (-30°C to 60°C)
Operating Relative Humidity (% RH Without Condensation) 0% to 90%, 32°F to 95°F (0°C to 35°C)
0% to 70%, 95°F to 113°F (35°C to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating Altitude 13,123 ft (4,000 m)
10,500 ft (3,200 m) with AC Adapter
EMC EN 61326-1
General Specifications
Autotest Time Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds
Support Test Parameters Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End
Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main Unit and Remote Lithium ion battery pack, 7.2 V
Typical Battery Life 8 hours
Charge time Tester off: 4 hours to charge from 10 % capacity to 90 % capacity
Languages Supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Click here for complete specifications on the Fluke Networks DSX2-8000QOI

What's included with the Fluke Networks DSX2-8000QOI

  • Versiv Mainframe & Remote
  • 2 x DSX-8000 CableAnalyzer Modules
  • OptiFiber Quad OTDR Module
  • Set of Cat 8/Class I Permanent Link Adapters
  • Set of Cat 8/Class 1 Channel Adapters
  • 2 x Headsets
  • 2 x Hand Straps
  • 2 x Shoulder Straps
  • Hard sided Carry Case
  • USB Interface Cable
  • Versiv Open Source Software CD
  • 2 x AC Chargers
  • 2 x Universal Couplers
  • 2 x AxTalk Terminators
  • 2 x Quick Clean Cleaners (1.25/2.50 mm)
  • SC/SC Simplex adapters
  • 2 x SC/LC Multimode Launch Cables—50 µm
  • 2 x SC/LC Singlemode Launch Cable—9 µm
  • USB Fiber Inspection Video Probe with 4 Tips
  • 2 x LC/LC Simplex Adapter
  • SC/LC EF-Compliant MM TRC Kit 50 µm
  • SC/LC SM TRC Kit
  • TRC Carrying Case
  • Statement of Calibration
  • Getting Started Guides

Click on a category to view a selection of compatible accessories with the Fluke Networks DSX2-8000QOI 2GHZ DSX Quad OTDR OLTS INSPC.

Fluke Networks DSX-8000-ADD 2GHZ DSX CableAnalyzer Modules Add on Kit DSX-8000-ADD
Modules add on kit for the DSX-8000 CableAnalyzer series.




Fluke Networks DSX-8000-OFP-Q-ADD 2GHZ DSX and Quad OTDR Modules Add on Kit DSX-8000-OFP-Q-ADD
DSX and Quad OTDR modules add on Kit for the DSX-8000 CableAnalyzer series.




Fluke Networks DSX-8000-MOD 2GHZ DSX Module Replacement, 1 Unit DSX-8000-MOD
Replacement module for the DSX-8000 CableAnalyzer series.




Fluke Networks DSX-REFCAL2G 2GHZ Set Reference CAL Artifact DSX-REFCAL2G
Set-Ref module for the DSX-8000 CableAnalyzer series.




Ask a question about Fluke Networks DSX2-8000QOI 2GHZ DSX Quad OTDR OLTS INSPC

Customer Reviews for the Fluke Networks DSX2-8000QOI

Fluke Networks DSX2-8000QOI Offers

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provide accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements and the difference between being profitable or not can be just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy (making jobs easier to manage), and getting to system acceptance faster. It's not just for the expert technicians and project managers, individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Features

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  • ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Fluke Networks DSX2-8000QOI Specifications

Copper Certifications
Category 6A / Class EA Test Time 8 Seconds
Category 8 / Class I/II Test Time 15 Seconds
HDTDX/HDTDR Diagnostic Test Times ~3 Seconds
Internal Memory ~5,000 Cat 8 with plots
~12,000 Cat 6A with plots
Level V Accuracy 1 GHz
2G Accuracy 2 GHz
Resistance Unbalance Measurement Yes
Shield Integrity Check Yes
TCL Measurement Yes
ELTCTL Measurement Yes
CDNEXT Measurement Yes
CMRL Measurement Yes
Built in Alien XTalk Module Yes
Channel Adapter 2 GHz Range
Permanent Link Adapter 2 GHz Range
Environmental
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -22°F to 140°F (-30°C to 60°C)
Operating Relative Humidity (% RH Without Condensation) 0% to 90%, 32°F to 95°F (0°C to 35°C)
0% to 70%, 95°F to 113°F (35°C to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating Altitude 13,123 ft (4,000 m)
10,500 ft (3,200 m) with AC Adapter
EMC EN 61326-1
General Specifications
Autotest Time Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds
Support Test Parameters Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End
Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main Unit and Remote Lithium ion battery pack, 7.2 V
Typical Battery Life 8 hours
Charge time Tester off: 4 hours to charge from 10 % capacity to 90 % capacity
Languages Supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Click here for complete specifications on the Fluke Networks DSX2-8000QOI

What's included with the Fluke Networks DSX2-8000QOI

  • Versiv Mainframe & Remote
  • 2 x DSX-8000 CableAnalyzer Modules
  • OptiFiber Quad OTDR Module
  • Set of Cat 8/Class I Permanent Link Adapters
  • Set of Cat 8/Class 1 Channel Adapters
  • 2 x Headsets
  • 2 x Hand Straps
  • 2 x Shoulder Straps
  • Hard sided Carry Case
  • USB Interface Cable
  • Versiv Open Source Software CD
  • 2 x AC Chargers
  • 2 x Universal Couplers
  • 2 x AxTalk Terminators
  • 2 x Quick Clean Cleaners (1.25/2.50 mm)
  • SC/SC Simplex adapters
  • 2 x SC/LC Multimode Launch Cables—50 µm
  • 2 x SC/LC Singlemode Launch Cable—9 µm
  • USB Fiber Inspection Video Probe with 4 Tips
  • 2 x LC/LC Simplex Adapter
  • SC/LC EF-Compliant MM TRC Kit 50 µm
  • SC/LC SM TRC Kit
  • TRC Carrying Case
  • Statement of Calibration
  • Getting Started Guides

Click on a category to view a selection of compatible accessories with the Fluke Networks DSX2-8000QOI 2GHZ DSX Quad OTDR OLTS INSPC.

Fluke Networks DSX-8000-ADD 2GHZ DSX CableAnalyzer Modules Add on Kit DSX-8000-ADD
Modules add on kit for the DSX-8000 CableAnalyzer series.




Fluke Networks DSX-8000-OFP-Q-ADD 2GHZ DSX and Quad OTDR Modules Add on Kit DSX-8000-OFP-Q-ADD
DSX and Quad OTDR modules add on Kit for the DSX-8000 CableAnalyzer series.




Fluke Networks DSX-8000-MOD 2GHZ DSX Module Replacement, 1 Unit DSX-8000-MOD
Replacement module for the DSX-8000 CableAnalyzer series.




Fluke Networks DSX-REFCAL2G 2GHZ Set Reference CAL Artifact DSX-REFCAL2G
Set-Ref module for the DSX-8000 CableAnalyzer series.




Ask a question about Fluke Networks DSX2-8000QOI 2GHZ DSX Quad OTDR OLTS INSPC

Customer Reviews for the Fluke Networks DSX2-8000QOI

More Fluke Networks Products

Calibration Lab