Fluke Networks CFP2-100-M-NW CertiFiber® Pro OLTS V2 Kit, multimode

Model: CFP2-100-M-NW | UPC: 754082144755

Fluke Networks CFP2-100-M-NW CertiFiber® Pro OLTS V2 Kit, multimode

Model: CFP2-100-M-NW | UPC: 754082144755

Improves every step of the fiber certification process by simplifying the set-up and speeding up test time and troubleshooting. Features the ProjX™ for managing every job efficiently and a Pass/Fail analysis to industry standards or custom test limits. This kit includes a mainframe, 2 x CertiFiber Pro modules, and accessories.

Improves every step of the fiber certification process by simplifying the set-up and speeding up test time and troubleshooting. Features the ProjX™ for managing every job efficiently and a Pass/Fail analysis to industry standards or custom test limits. This kit includes a mainframe, 2 x CertiFiber Pro modules, and accessories.

Sale Price $9616.84 USD
Regular Price $10122.99 USD
Availability 2 to 3 Weeks
Quantity

Fluke Networks CFP2-100-M-NW Offers

CertiFiber Pro Optical Loss Test Kit offers a complete solution for certifying, troubleshooting, and documenting fiber optic network cabling. In addition, these fully-featured set of testers are designed to accelerate every step of the fiber certification process.

Enabling the CertiFiber Pro Optical Loss Test Set to be future-ready, the Versiv platform pairs with the OptiFiber Pro module, providing merged Tier 1 (Basic)/Tier 2 (Extended) testing and reporting. Moreover, copper certification, Wi-Fi analysis, and Ethernet troubleshooting modules are available. Analyze test results and generate professional test reports using LinkWare Management Software.

Features

  • Optical loss test set with fastest time to certify - two fibers at two wavelengths in under three seconds
  • Encircled Flux compliant as required by ANSI/TIA and ISO/IEC
  • ProjX™ management system ensures all jobs are completed correctly and efficiently
  • Optical loss test set provides automatic Pass/Fail analysis to industry standards or custom test limits
  • Double ended Pass/Fail certification of fiber optic connector endfaces
  • Graphical indication of problem areas on fiber endfaces due to contamination, pits, chips and scratches
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Taptive™ user interface provides simple, animated guidance to eliminate incorrect reference setup and "negative loss" errors
  • Optical loss test set with built in Visual Fault Locator
  • Analyze test results and create professional test reports using LinkWare™ Management Software
  • Compatible with LinkWare™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software

Applications

  • Telecommunications and datacom network testing
  • Enterprise network certification
  • Quality control in network installations
  • Troubleshooting and repair
  • Data center maintenance

Fluke Networks CFP2-100-M-NW Specifications

Power Meter
Input Connector Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type InGaAs
Wavelengths 850, 1300, 1310, 1550 nm
Power Measurement Range: 0 to -65 dBm (850 nm), 0 to -70 dBm (all other wavelengths)
Uncertainty: <±5% ±32 pW
Measurement Linearity <±0.1 dB
Integrated Wi-Fi Meets IEEE 802.11 a/b/g/n; dual band (2.4 and 5 GHz)
Loss/Length
Testing Speeds (excludes referencing times) Smart Remote mode: <3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: <2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Fiber Types Tested 50/125 μm or 62.5/125 μm
Source Type and Wavelengths Source: LED
850 ±30 nm, 1300 ±20 nm
Measurement Maximum length: 39,370' (12,000 m)
Length accuracy: ±4.92' (1.5 m) plus ±1% of length
Output Power Nominal: ≥-24 dBm with EF-TRC
Stability: ±0.05 dB over 8 hours ±0.03 dB over 15 minutes
Visual Fault Locator (VFL)
Output Power >-5 dBm | <0 dBm | SMF-28 singlemode fiber | continuous wave | SC/UPC connector
Operating Wavelength 650 nm nominal
Output Modes Continuous wave
Pulsed mode (2 to 3 Hz blink frequency)
Connector Adapter 2.5 mm universal
Laser Safety Class II CDRH
Over operating temperature range
General Specifications
Environmental Conditions Operating temperature: 14 to 113°F (-10 to 45°C)
Storage temperature: 14 to 140°F (-10 to 60°C)
Operating relative humidity (% RH without condensation): 0 to 90%, 32 to 95°F (0 to 35°C) | 0 to 70%, 95 to 113°F (35 to 45°C)
Vibration Random, 2 g, 5 to 500 Hz
Shock 3.28' (1 m) drop test with and without module and adapters
Altitude Operating: 13,123' (4000 m)
Storage: 39,370' (12,000 m)
Pollution Degree 2
Safety CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2
EMC EN 61326–1
Click here for complete specifications on the Fluke Networks CFP2-100-M-NW

What's included with the Fluke Networks CFP2-100-M-NW

  • Versiv Mainframe and Remote
  • 2 x Multimode OLTS Modules
  • Statement of Calibration
  • SC/LC MM TRC Kit
  • 2 x LC/LC Adaptors
  • 2 x Hand Straps
  • 2 x Shoulder Straps
  • TRC Carrying Case
  • Carrying Case
  • 2 x Chargers
  • USB Cable

Ask a question about Fluke Networks CFP2-100-M-NW CertiFiber® Pro OLTS V2 Kit, multimode

Customer Reviews for the Fluke Networks CFP2-100-M-NW

Fluke Networks CFP2-100-M-NW Offers

CertiFiber Pro Optical Loss Test Kit offers a complete solution for certifying, troubleshooting, and documenting fiber optic network cabling. In addition, these fully-featured set of testers are designed to accelerate every step of the fiber certification process.

Enabling the CertiFiber Pro Optical Loss Test Set to be future-ready, the Versiv platform pairs with the OptiFiber Pro module, providing merged Tier 1 (Basic)/Tier 2 (Extended) testing and reporting. Moreover, copper certification, Wi-Fi analysis, and Ethernet troubleshooting modules are available. Analyze test results and generate professional test reports using LinkWare Management Software.

Features

  • Optical loss test set with fastest time to certify - two fibers at two wavelengths in under three seconds
  • Encircled Flux compliant as required by ANSI/TIA and ISO/IEC
  • ProjX™ management system ensures all jobs are completed correctly and efficiently
  • Optical loss test set provides automatic Pass/Fail analysis to industry standards or custom test limits
  • Double ended Pass/Fail certification of fiber optic connector endfaces
  • Graphical indication of problem areas on fiber endfaces due to contamination, pits, chips and scratches
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Taptive™ user interface provides simple, animated guidance to eliminate incorrect reference setup and "negative loss" errors
  • Optical loss test set with built in Visual Fault Locator
  • Analyze test results and create professional test reports using LinkWare™ Management Software
  • Compatible with LinkWare™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software

Applications

  • Telecommunications and datacom network testing
  • Enterprise network certification
  • Quality control in network installations
  • Troubleshooting and repair
  • Data center maintenance

Fluke Networks CFP2-100-M-NW Specifications

Power Meter
Input Connector Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type InGaAs
Wavelengths 850, 1300, 1310, 1550 nm
Power Measurement Range: 0 to -65 dBm (850 nm), 0 to -70 dBm (all other wavelengths)
Uncertainty: <±5% ±32 pW
Measurement Linearity <±0.1 dB
Integrated Wi-Fi Meets IEEE 802.11 a/b/g/n; dual band (2.4 and 5 GHz)
Loss/Length
Testing Speeds (excludes referencing times) Smart Remote mode: <3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: <2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Fiber Types Tested 50/125 μm or 62.5/125 μm
Source Type and Wavelengths Source: LED
850 ±30 nm, 1300 ±20 nm
Measurement Maximum length: 39,370' (12,000 m)
Length accuracy: ±4.92' (1.5 m) plus ±1% of length
Output Power Nominal: ≥-24 dBm with EF-TRC
Stability: ±0.05 dB over 8 hours ±0.03 dB over 15 minutes
Visual Fault Locator (VFL)
Output Power >-5 dBm | <0 dBm | SMF-28 singlemode fiber | continuous wave | SC/UPC connector
Operating Wavelength 650 nm nominal
Output Modes Continuous wave
Pulsed mode (2 to 3 Hz blink frequency)
Connector Adapter 2.5 mm universal
Laser Safety Class II CDRH
Over operating temperature range
General Specifications
Environmental Conditions Operating temperature: 14 to 113°F (-10 to 45°C)
Storage temperature: 14 to 140°F (-10 to 60°C)
Operating relative humidity (% RH without condensation): 0 to 90%, 32 to 95°F (0 to 35°C) | 0 to 70%, 95 to 113°F (35 to 45°C)
Vibration Random, 2 g, 5 to 500 Hz
Shock 3.28' (1 m) drop test with and without module and adapters
Altitude Operating: 13,123' (4000 m)
Storage: 39,370' (12,000 m)
Pollution Degree 2
Safety CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2
EMC EN 61326–1
Click here for complete specifications on the Fluke Networks CFP2-100-M-NW

What's included with the Fluke Networks CFP2-100-M-NW

  • Versiv Mainframe and Remote
  • 2 x Multimode OLTS Modules
  • Statement of Calibration
  • SC/LC MM TRC Kit
  • 2 x LC/LC Adaptors
  • 2 x Hand Straps
  • 2 x Shoulder Straps
  • TRC Carrying Case
  • Carrying Case
  • 2 x Chargers
  • USB Cable

Ask a question about Fluke Networks CFP2-100-M-NW CertiFiber® Pro OLTS V2 Kit, multimode

Customer Reviews for the Fluke Networks CFP2-100-M-NW

More Fluke Networks Products

Calibration Lab